The TPZT-1000 is a portable plant physiology instrument that measures air temperature, humidity, leaf temperature, and PAR, while calculating transpiration rate and stomatal conductance. With high-precision sensors and a customizable 55×20mm leaf chamber, it’s ideal for plant species studies. Weighing 3.25kg, it’s perfect for both lab and field research, providing reliable data for plant-environment water relations analysis.
Modles : TPZT‐1000
whatsapp Whatsapp

The TPZT-1000 is a high-precision, portable device for measuring plant transpiration and stomatal conductance. It simultaneously monitors air/leaf temperature, humidity, and PAR, providing instant calculations for critical plant physiology parameters.

Featuring a user-friendly interface with real-time data display, its compact design (3.25kg) ensures easy field operation. The customizable leaf chamber adapts to various plants, from crops to vegetables, while robust construction withstands harsh conditions (0-100% RH, 20-50°C).

With lab-grade accuracy (±0.2°C, ±3% RH) and 9-hour battery life, the TPZT-1000 delivers reliable data for research in agronomy, ecology, and irrigation optimization—all at a competitive price.

 

Feature:

  • Multiple parameters tested: test air temperature, leaf temperature, air humidity, PAR etc at same time,and count the transpiration rate and Stomatal conductance accordingly.
  • Intelligent: Menu display and Cursor operation; test process and results displayed in real‐time, withsmall size, light, portable and one‐person operation.
  • Widely application: with different leaf chamber, the meter is able to be used in field crops, fruit andvegetables, hay etc which are in different shape

Cost‐efficiency: very competitive price and convenient maintenance

Specifications :

No. Parameter Specifications
1 Air Temperature (TL) High-accuracy digital sensor (Swaziland)
Range: 0–50℃
Resolution: 0.1℃
Error: ±0.2℃
2 Leaf Temperature (TC) Platinum sensor
Range: 0–50℃
Resolution: 0.1℃
Error: ±0.2℃
3 Air Humidity (RH) High-accuracy digital sensor (Swaziland)
Range: 0–100%
Resolution: 0.1%
Error: ≤±3%
4 PAR Silicon photocell with correction filter
Range: 0–2500 µmol/m²/s
Accuracy: <5 µmol/m²/s
5 Flux Glass rotameter
6 Leaf Chamber Size Standard: 55 mm × 20 mm
Customizable available
7 Work Environment Temperature: 20–50℃
Humidity: 0–100% (non-condensing)
8 Power DC 7.4V Li-ion Battery
Runtime: 7–9 hours continuous operation
9 Data Storage 2GB SD card
10 Display 320 × 160 lattice screen
11 Dimensions 260 × 260 × 130 mm
12 Weight 3.25 kg
No. Parameter Specifications
1 Air Temperature (TL) High-accuracy digital sensor (Swaziland)
Range: 0–50℃
Resolution: 0.1℃
Error: ±0.2℃
2 Leaf Temperature (TC) Platinum sensor
Range: 0–50℃
Resolution: 0.1℃
Error: ±0.2℃
3 Air Humidity (RH) High-accuracy digital sensor (Swaziland)
Range: 0–100%
Resolution: 0.1%
Error: ≤±3%
4 PAR Silicon photocell with correction filter
Range: 0–2500 µmol/m²/s
Accuracy: <5 µmol/m²/s
5 Flux Glass rotameter
6 Leaf Chamber Size Standard: 55 mm × 20 mm
Customizable available
7 Work Environment Temperature: 20–50℃
Humidity: 0–100% (non-condensing)
8 Power DC 7.4V Li-ion Battery
Runtime: 7–9 hours continuous operation
9 Data Storage 2GB SD card
10 Display 320 × 160 lattice screen
11 Dimensions 260 × 260 × 130 mm
12 Weight 3.25 kg

Request Quote: Plant Transpiration Rate Meter TPZT‐1000