AELAB WJ-3T CO₂ Incubator – Precise Cell Culture (WJ Series)

The AELAB WJ Series CO₂ incubators (WJ-3T, WJ-3-160T, WJ-3-270T, LCI-1000T) stabilize temperature from RT+5–60 °C and regulate 0–20% CO₂ using PID control and an imported infrared sensor. With ≤±0.2 °C temperature stability, ±0.3 °C uniformity, forced air convection, and Natural Vaporization humidification, these chambers deliver reproducible cell, tissue, and bacterial culture performance across 80–1000 L capacities.
Modles : WJ Series
whatsapp Whatsapp

CO2 Incubator is widely used in modern medicine, biology, chemistry and agriculture science for the culture of biological cells, tissues and bacterial.

Microcomputer control, touch screen, accurate and easy for operation. Imported infrared CO2 sensor and gold-plated probes to ensure accuracy, long life time.

 

⚙️ Design & Construction

The AELAB WJ-3T CO₂ Incubator adopts water jacket and air jacket structures with a polished Stainless-Steel chamber and powder coated steel plate housing. A fan provides forced convection to ensure temperature uniformity and the balance of CO₂ concentration inside. UV sterilization is equipped. The door-open interlock turns off the fan and CO₂ intake valve and suspends heating to reduce contamination risk. The system includes leakage protection and a spare mechanical thermostat to maintain operation if the main temperature controller fails. A φ16 mm testing hole is provided on the inner door.

 

🔬 Working Principle / Testing Method

PIDs regulate temperature from RT+5–60 °C with ≤±0.2 °C stability and ±0.3 °C uniformity. The AELAB WJ-3T CO₂ Incubator uses an imported infrared CO₂ sensor with gold-plated probes; CO₂ concentration can be freely set from 0–20% with ±0.1% control accuracy. Over-concentration and slow concentration-rise alarms are provided. Natural Vaporization maintains chamber humidity, supporting consistent cell and tissue culture environments.

 

💡 Key Advantages

  • 0–20% CO₂ set range with ±0.1% control accuracy for precise culture conditions
  • RT+5–60 °C temperature range with ≤±0.2 °C stability and ±0.3 °C uniformity
  • Forced air convection for rapid recovery and uniform gas distribution
  • Door-open interlock, leakage breaker, and multiple alarms for safe operation
  • UV sterilization and φ16 mm testing hole to support sterile sampling and monitoring
  • Four capacities from 80 L to 1000 L to fit research to production-scale incubation
  • Water jacket or air jacket configurations with durable Stainless-Steel chamber

 

🔗 Connectivity & Integration

The microcomputer touch interface of the AELAB WJ-3T CO₂ Incubator enables parameter setting, alarms, and status display. External data ports or software interfaces are not specified in the catalog; laboratories may document readings per GLP procedures.

 

🧠 Model Insight

Model Chamber Volume (L) Power Rating (W) Chamber Size (W×D×H) cm Exterior Size (W×D×H) cm
WJ-3T 80 600 41*44*51 56*64*90
WJ-3-160T 160 900 50*51*65 65*73*105
WJ-3-270T 270 1400 60*60*77 72*75*112
LCI-1000T 1000 2600 100*100*96 115.3*117.5*143.3

🧪 Testing Applications

The AELAB WJ-3T CO₂ Incubator regulates stable temperature and CO₂ for the culture of biological cells, tissues, and bacterial samples. Typical use cases include medical research, biotechnology cell lines, pharmaceutical development, environmental microbiology, and food or agricultural science incubation workflows.

 

Compliance & Quality Assurance

AELAB manufactures the WJ Series under strict quality control suitable for ISO/GLP-style laboratory documentation. Safety functions include over-temperature protection, leakage breaker, and audible/visual alarms. Specific third-party certifications are not listed in the catalog.

Specifications :

Model WJ-3T WJ-3-160T WJ-3-270T LCI-1000T
Chamber Volume (L) 80 160 270 1000
Temperature Range RT +5 ~ 60 ℃
Temperature Stability ≤ ±0.2 ℃
Temperature Uniformity ± 0.3 ℃
CO₂ Range 0 ~ 20 %
CO₂ Control Accuracy ± 0.1 % (Imported sensor)
Humidity Method Natural Vaporization
Power Supply AC 220 V 50 Hz
Device Safety Over-Temperature safety, Leakage breaker & Alarm Function
Convection Forced air convection
Testing Hole (on inner door) φ 16 mm
Operating Temperature (Ambient) +18 ~ 30 ℃
Perforated Shelf (Std / Max) 2 / 10 3 / 13 3 / 16 3 / 18
Power Rating (W) 600 900 1400 2600
Chamber Size (W×D×H) cm 41 × 44 × 51 50 × 51 × 65 60 × 60 × 77 100 × 100 × 96
Exterior Size (W×D×H) cm 56 × 64 × 90 65 × 73 × 105 72 × 75 × 112 115.3 × 117.5 × 143.3
Options Pressure reducing regulator valve / HEPA filter system / Optional shelves
Model WJ-3T WJ-3-160T WJ-3-270T LCI-1000T
Chamber Volume (L) 80 160 270 1000
Temperature Range RT +5 ~ 60 ℃
Temperature Stability ≤ ±0.2 ℃
Temperature Uniformity ± 0.3 ℃
CO₂ Range 0 ~ 20 %
CO₂ Control Accuracy ± 0.1 % (Imported sensor)
Humidity Method Natural Vaporization
Power Supply AC 220 V 50 Hz
Device Safety Over-Temperature safety, Leakage breaker & Alarm Function
Convection Forced air convection
Testing Hole (on inner door) φ 16 mm
Operating Temperature (Ambient) +18 ~ 30 ℃
Perforated Shelf (Std / Max) 2 / 10 3 / 13 3 / 16 3 / 18
Power Rating (W) 600 900 1400 2600
Chamber Size (W×D×H) cm 41 × 44 × 51 50 × 51 × 65 60 × 60 × 77 100 × 100 × 96
Exterior Size (W×D×H) cm 56 × 64 × 90 65 × 73 × 105 72 × 75 × 112 115.3 × 117.5 × 143.3
Options Pressure reducing regulator valve / HEPA filter system / Optional shelves

Frequently Asked Questions

1What are the recommended operating conditions?
Ambient operating temperature is +18–30 °C with forced air convection and Natural Vaporization humidification.
2What temperature and CO₂ ranges does the AELAB WJ-3T support?
Temperature RT+5–60 °C; CO₂ concentration 0–20% with ±0.1% control accuracy.
3What is the temperature performance of the chamber?
Temperature stability is ≤±0.2 °C and temperature uniformity is ±0.3 °C.
4What safety protections are included?
Over-temperature safety, leakage breaker, and alarm functions; door-open interlock stops the fan and CO₂ intake valve and suspends heating.

Request Quote: AELAB WJ-3T CO₂ Incubator – Precise Cell Culture (WJ Series)