CO2 Incubator is widely used in modern medicine, biology, chemistry and agriculture science for the culture of biological cells, tissues and bacterial.
Microcomputer control, touch screen, accurate and easy for operation. Imported infrared CO2 sensor and gold-plated probes to ensure accuracy, long life time.
The AELAB WJ-3T CO₂ Incubator adopts water jacket and air jacket structures with a polished Stainless-Steel chamber and powder coated steel plate housing. A fan provides forced convection to ensure temperature uniformity and the balance of CO₂ concentration inside. UV sterilization is equipped. The door-open interlock turns off the fan and CO₂ intake valve and suspends heating to reduce contamination risk. The system includes leakage protection and a spare mechanical thermostat to maintain operation if the main temperature controller fails. A φ16 mm testing hole is provided on the inner door.
PIDs regulate temperature from RT+5–60 °C with ≤±0.2 °C stability and ±0.3 °C uniformity. The AELAB WJ-3T CO₂ Incubator uses an imported infrared CO₂ sensor with gold-plated probes; CO₂ concentration can be freely set from 0–20% with ±0.1% control accuracy. Over-concentration and slow concentration-rise alarms are provided. Natural Vaporization maintains chamber humidity, supporting consistent cell and tissue culture environments.
The microcomputer touch interface of the AELAB WJ-3T CO₂ Incubator enables parameter setting, alarms, and status display. External data ports or software interfaces are not specified in the catalog; laboratories may document readings per GLP procedures.
| Model | Chamber Volume (L) | Power Rating (W) | Chamber Size (W×D×H) cm | Exterior Size (W×D×H) cm |
|---|---|---|---|---|
| WJ-3T | 80 | 600 | 41*44*51 | 56*64*90 |
| WJ-3-160T | 160 | 900 | 50*51*65 | 65*73*105 |
| WJ-3-270T | 270 | 1400 | 60*60*77 | 72*75*112 |
| LCI-1000T | 1000 | 2600 | 100*100*96 | 115.3*117.5*143.3 |
The AELAB WJ-3T CO₂ Incubator regulates stable temperature and CO₂ for the culture of biological cells, tissues, and bacterial samples. Typical use cases include medical research, biotechnology cell lines, pharmaceutical development, environmental microbiology, and food or agricultural science incubation workflows.
AELAB manufactures the WJ Series under strict quality control suitable for ISO/GLP-style laboratory documentation. Safety functions include over-temperature protection, leakage breaker, and audible/visual alarms. Specific third-party certifications are not listed in the catalog.
Specifications :
| Model | WJ-3T | WJ-3-160T | WJ-3-270T | LCI-1000T |
|---|---|---|---|---|
| Chamber Volume (L) | 80 | 160 | 270 | 1000 |
| Temperature Range | RT +5 ~ 60 ℃ | |||
| Temperature Stability | ≤ ±0.2 ℃ | |||
| Temperature Uniformity | ± 0.3 ℃ | |||
| CO₂ Range | 0 ~ 20 % | |||
| CO₂ Control Accuracy | ± 0.1 % (Imported sensor) | |||
| Humidity Method | Natural Vaporization | |||
| Power Supply | AC 220 V 50 Hz | |||
| Device Safety | Over-Temperature safety, Leakage breaker & Alarm Function | |||
| Convection | Forced air convection | |||
| Testing Hole (on inner door) | φ 16 mm | |||
| Operating Temperature (Ambient) | +18 ~ 30 ℃ | |||
| Perforated Shelf (Std / Max) | 2 / 10 | 3 / 13 | 3 / 16 | 3 / 18 |
| Power Rating (W) | 600 | 900 | 1400 | 2600 |
| Chamber Size (W×D×H) cm | 41 × 44 × 51 | 50 × 51 × 65 | 60 × 60 × 77 | 100 × 100 × 96 |
| Exterior Size (W×D×H) cm | 56 × 64 × 90 | 65 × 73 × 105 | 72 × 75 × 112 | 115.3 × 117.5 × 143.3 |
| Options | Pressure reducing regulator valve / HEPA filter system / Optional shelves | |||
| Model | WJ-3T | WJ-3-160T | WJ-3-270T | LCI-1000T |
|---|---|---|---|---|
| Chamber Volume (L) | 80 | 160 | 270 | 1000 |
| Temperature Range | RT +5 ~ 60 ℃ | |||
| Temperature Stability | ≤ ±0.2 ℃ | |||
| Temperature Uniformity | ± 0.3 ℃ | |||
| CO₂ Range | 0 ~ 20 % | |||
| CO₂ Control Accuracy | ± 0.1 % (Imported sensor) | |||
| Humidity Method | Natural Vaporization | |||
| Power Supply | AC 220 V 50 Hz | |||
| Device Safety | Over-Temperature safety, Leakage breaker & Alarm Function | |||
| Convection | Forced air convection | |||
| Testing Hole (on inner door) | φ 16 mm | |||
| Operating Temperature (Ambient) | +18 ~ 30 ℃ | |||
| Perforated Shelf (Std / Max) | 2 / 10 | 3 / 13 | 3 / 16 | 3 / 18 |
| Power Rating (W) | 600 | 900 | 1400 | 2600 |
| Chamber Size (W×D×H) cm | 41 × 44 × 51 | 50 × 51 × 65 | 60 × 60 × 77 | 100 × 100 × 96 |
| Exterior Size (W×D×H) cm | 56 × 64 × 90 | 65 × 73 × 105 | 72 × 75 × 112 | 115.3 × 117.5 × 143.3 |
| Options | Pressure reducing regulator valve / HEPA filter system / Optional shelves | |||
Download catalog for: