info@aelabgroup.com

AELAB Fluorescence Spectrophotometer F98 – High Sensitivity & Speed

The AELAB F98 Fluorescence Spectrophotometer delivers ultra-high scanning speeds, unmatched signal-to-noise ratio, and precision wavelength control. Ideal for researchers, it supports accurate qualitative and quantitative analysis across fields such as biochemistry, water quality testing, and pharmaceutical development.

Modles : F98
whatsapp Whatsapp

F98 fluorescence spectrophotometer is a new generation of high-performance molecular luminescence analysis equipment. This product is designed for high performance, with high signal to noise ratio, ultra-high scanning speed, ultra-high resolution, ultra-high wavelength accuracy and a variety of accessories. This instrument easily meets the requirements in material research, drug analysis, biochemical and clinical testing, water quality control, food safety testing and other areas of qualitative and quantitative analysis and scientific research. Quantum yield accessory is available for F98 fluorescence spectrophotometer.

 

Features:

  • Horizontal slit optical design, with excellent luminous detection efficiency and high signal to noise ratio. Water Raman peak SNR better than 350: 1 (P-P) or 18000: 1 (RMS BG). The minimum sample volume is 0.5mL when using a standard 10mm square sample cell.
  • Wavelength scanning speed up to 60000 nm / min.
  • Bandwidth 1/2/5/10/20nm adjustable.
  • Fluorescence Quantum Yield accessory available.
  • The software offers fluorescence 3D scanning, equal-wavelength difference
  • Synchronous scanning, equal wave number difference (constant energy difference) synchronous scanning functions. (synchronous scanning function require pro version software)
  • Multi accessories available.
  • Using Hamamatsu’s high quality Xenon light source and photoelectric multiplier tube detectors and instruments to provide sufficient light intensity signal and the detection sensitivity.
  • Built-in frequency filter. Built-in optical gate, designed for unstable sample.

 

🔬 How It Works?

The F98 operates on fluorescence spectrophotometry principles, detecting emitted light from a sample excited by high-intensity xenon light. Using a horizontal slit design and Hamamatsu photo-multiplier tube, it captures even the faintest luminescence with extreme precision. Its software supports 3D scanning, synchronous scanning, and quantum yield measurement, providing flexible, multi-dimensional analysis for complex applications.

 

💡 Advantages

  • Ultra-High Signal-to-Noise Ratio – Exceptional clarity for trace analysis

  • 60000 nm/min Scan Speed – Fastest in its class for high-throughput labs

  • Precise Wavelength Control – Adjustable slit widths and ±0.4 nm accuracy

  • Versatile Software Functions – Supports 3D and synchronous scanning modes

  • Quantum Yield Accessory Available – Enhanced research capability

  • Compact Yet Powerful – Lightweight design with only 0.5 mL sample requirement

 

🔍 Recommended Models by Use Case

Use Case Recommended Model
Academic & Teaching Labs F98 Standard Model
Pharmaceutical Research F98 + Quantum Yield Accessory
Food Safety & Environmental Testing F98 with 3D Scanning Software
QC in Industrial Settings F98 Pro Version with Auto Scanning

 

🧪 Ideal For

  • Biotechnology and pharmaceutical labs

  • Food safety and agricultural analysis

  • Environmental testing and water quality labs

  • Material science and nanotechnology research

  • Clinical biochemistry and medical diagnostics

Specifications :

Excitation Source 150W xenon lamp(Hamamatsu)
Excitation Wavelength 200nm~900nm
Emission Wavelength 200nm~900nm
Excitation Slit 1nm/2nm/5nm/10nm/20nm
Emission Slit 1nm/2nm/5nm/10nm/20nm
Wavelength Accuracy ±0.4nm
Wavelength Repeatability ≤0.2nm
Signal-to-Noise Ratio S/N≥350(P-P) ; S/N≥1500(RMS); S/N≥18000(RMS BG)
Limit ≤5×10-11 g/ml(Quinine Sulfate Solution)
Linearity γ≥0.995
Peak Repeatability ≤1.5%
Wavelength Scan Speed Multi-speed Level, Maximum at 60000nm/min
Minimum sample size 0.5mL (Using a standard 10mm square sample cell)
Octave filter Build in Octave filter
Photometric Quantity

Range

-9999 ~ 9999
Response Time 0.02/0.1/0.5/1/2/4/8 s,Auto adjust
Data Transportation USB2.0
Power 200W
Power Source AC 220V/50Hz; 110V/60Hz
Instrument Dimension 610×460×365(mm)
Weight Net Weight:21kg Gross Weight:26kg
Excitation Source 150W xenon lamp(Hamamatsu)
Excitation Wavelength 200nm~900nm
Emission Wavelength 200nm~900nm
Excitation Slit 1nm/2nm/5nm/10nm/20nm
Emission Slit 1nm/2nm/5nm/10nm/20nm
Wavelength Accuracy ±0.4nm
Wavelength Repeatability ≤0.2nm
Signal-to-Noise Ratio S/N≥350(P-P) ; S/N≥1500(RMS); S/N≥18000(RMS BG)
Limit ≤5×10-11 g/ml(Quinine Sulfate Solution)
Linearity γ≥0.995
Peak Repeatability ≤1.5%
Wavelength Scan Speed Multi-speed Level, Maximum at 60000nm/min
Minimum sample size 0.5mL (Using a standard 10mm square sample cell)
Octave filter Build in Octave filter
Photometric Quantity

Range

-9999 ~ 9999
Response Time 0.02/0.1/0.5/1/2/4/8 s,Auto adjust
Data Transportation USB2.0
Power 200W
Power Source AC 220V/50Hz; 110V/60Hz
Instrument Dimension 610×460×365(mm)
Weight Net Weight:21kg Gross Weight:26kg

Frequently Asked Questions

1How is calibration done on the F98?
AELAB provides an auto-calibration feature via its software interface using standard reference samples.
2Is the device GMP compliant?
Yes, the F98 meets Good Manufacturing Practice (GMP) standards when used with proper SOPs and traceable calibration.
3What is the warranty period?
The F98 spectrophotometer comes with a 1-year international warranty, with extended options available.

Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.

Request Quote: AELAB Fluorescence Spectrophotometer F98 – High Sensitivity & Speed