The AELAB Y09–3016 Laser Particle Counter uses advanced light scattering technology for real-time, high-precision measurement of airborne particles. With a sensitive semiconductor laser, multi-mode testing, and real-time environmental data display, it's a reliable tool for cleanroom monitoring, air quality audits, and industrial hygiene assessments.
The Y09 – 3016 Laser Particle Counter utilizes the principle of light scattering to measure the size and concentration of particles suspended in the air. When particles enter the photosensitive detection area, they cause light to scatter. The intensity of the scattered light is directly related to the size of the particle. This scattered light is then converted through a photoelectric process, amplified, and analyzed to determine the equivalent diameter and the number of particles present in the air. This advanced method ensures highly accurate and reliable particle counting for air quality monitoring and industrial applications.
Features
Light Scattering Principle: Utilizes light scattering to detect airborne particles, ensuring precise and reliable particle size and concentration measurements.
Real-Time Monitoring: Continuously measures and provides real-time data on particle size and number, ideal for ongoing air quality assessments.
High Sensitivity: Capable of detecting even the smallest particles with high accuracy, providing detailed insights into air quality.
Photoelectric Conversion: Scattered light is converted to electrical signals through a photoelectric process, ensuring accurate data collection and analysis.
Wide Particle Size Range: Supports a broad range of particle sizes, making it suitable for various environments and applications.
Compact and Portable: Designed to be lightweight and portable, allowing for easy installation and use in different settings, including laboratories, clean rooms, and industrial environments.
User-Friendly Interface: Features an intuitive interface for easy operation, data interpretation, and adjustments.
High Measurement Accuracy: Provides precise particle counting with high resolution, ensuring reliable results for air quality monitoring.
Low Maintenance: Built for minimal upkeep, reducing operational costs and downtime.
Durable and Reliable: Engineered for long-term performance in demanding environments, offering consistent and durable functionality over time.
Y09–3016 Standard Configuration: Best for cleanroom compliance validation, environmental research labs, and onsite audits with built-in data storage and flexible test modes.
With Optional Accessories: Ideal for continuous monitoring in regulated industries needing external printing or enhanced temperature/humidity logging.
Cleanroom air validation in semiconductor, pharmaceutical, and biotechnology industries
Environmental air quality analysis in labs, universities, and public health institutions
Food and beverage production requiring airborne particle control
Cosmetics and personal care facilities monitoring for airborne contaminants
Medical device manufacturing and GMP compliance testing
HVAC testing and clean bench validation
Specifications :
| Light source | Semiconductor laser, life is more than 35000 hours |
| Sampling flow | 2.83L/min (0.1CFM) Imported Pump |
| Display | LCD Real - time display, a period, the concentration of the real - time display, can display time, date, measurement time, temperature and humidity, total number of sampling points, sampling, battery state parameters, such as UCL computing function, can be converted to show the particle concentration (m³) |
| Rechargeable battery | Lithium ion battery, 7.4V 2200mAh |
| Power supply | External AC power adapter AC: 100V - 245V 50/60Hz to DC: 7.4V 1A |
| Working time | 6 hours (Provide a fuel gauge of remaining battery capacity) |
| Count mode | The cumulative values, the difference and density |
| Test mode | Single, repetitive, continuous, computing, remote |
| Unit conversion | The unit can be converted to m³ |
| Particle channel | 0.3, 0.5, 1, 3, 5, 10um |
| Sampling period | 1 - 100000[s] time - delay: 0 - 99[S] Self - cleaning time: ≤ 10 [min] |
| Work environment | Temperature: 10 - 40℃ (50 - 104℉) Relative humidity: 20 - 90% RH, no dew, Atmospheric pressure: 86 - 106kPa |
| Temperature and humidity | (1) Temperature: 0 - 50℃ ± 1℃; (2) Humidity: 0 - 100% RH ± 5% (Optionally available) |
| UCL Set | Sampling number(2 - 9 point set), Each point sampling time: (1 - 99min set) UCL measurement setup: 0 - 999 |
| UCL report forms | Meet the standards of ISO14644 - 1, GB50373 - 2011, GMPP, FS - 209E |
| Data store | Can store 1000 Groups data (circulation buffer) including data: particle data, environment data: year month, dayr time, sampling number, data, etc. The data is not lost when the power is cut off. |
| Communication interface | RS232, 9600 Baud rate |
| Zero count | Insts: 3000 level, clean room function, can to clean room grade: 100 grade 1000 grade 10000 grade 100000 grade measurement, with alarm: 100000 with excessive alarm and low battery, voltage alarm. |
| Alarm setting | Meet standards of JJG - 547 - 88the dust particle counter verification regulation requirements |
| Superposition errors | JS - 8921: 1997 Less than one every five minutes |
| Print function | 5%, 2000000Grain/cubic feet |
| Overall size | Cab connect the external printer (Optionally available) |
| Weight | 220×40×120 (mm) |
| 1kg | |
| Adjusting | Traceability to the national association of standard technology (NIST), our company has passed the national metrology standard approval, can be traced back to the Shanghai national institute of metrology measurement technology is available for calibration or third - party national metrology institute for calibration |
| Standard configuration | Suitcase, Charger, Sampling head, Null filter, RS232 connecting line, CD for computer communication software |
| Optional accessories | External printer, professional triangle sampling frame, temperature and humidity sensor |
| Light source | Semiconductor laser, life is more than 35000 hours |
| Sampling flow | 2.83L/min (0.1CFM) Imported Pump |
| Display | LCD Real - time display, a period, the concentration of the real - time display, can display time, date, measurement time, temperature and humidity, total number of sampling points, sampling, battery state parameters, such as UCL computing function, can be converted to show the particle concentration (m³) |
| Rechargeable battery | Lithium ion battery, 7.4V 2200mAh |
| Power supply | External AC power adapter AC: 100V - 245V 50/60Hz to DC: 7.4V 1A |
| Working time | 6 hours (Provide a fuel gauge of remaining battery capacity) |
| Count mode | The cumulative values, the difference and density |
| Test mode | Single, repetitive, continuous, computing, remote |
| Unit conversion | The unit can be converted to m³ |
| Particle channel | 0.3, 0.5, 1, 3, 5, 10um |
| Sampling period | 1 - 100000[s] time - delay: 0 - 99[S] Self - cleaning time: ≤ 10 [min] |
| Work environment | Temperature: 10 - 40℃ (50 - 104℉) Relative humidity: 20 - 90% RH, no dew, Atmospheric pressure: 86 - 106kPa |
| Temperature and humidity | (1) Temperature: 0 - 50℃ ± 1℃; (2) Humidity: 0 - 100% RH ± 5% (Optionally available) |
| UCL Set | Sampling number(2 - 9 point set), Each point sampling time: (1 - 99min set) UCL measurement setup: 0 - 999 |
| UCL report forms | Meet the standards of ISO14644 - 1, GB50373 - 2011, GMPP, FS - 209E |
| Data store | Can store 1000 Groups data (circulation buffer) including data: particle data, environment data: year month, dayr time, sampling number, data, etc. The data is not lost when the power is cut off. |
| Communication interface | RS232, 9600 Baud rate |
| Zero count | Insts: 3000 level, clean room function, can to clean room grade: 100 grade 1000 grade 10000 grade 100000 grade measurement, with alarm: 100000 with excessive alarm and low battery, voltage alarm. |
| Alarm setting | Meet standards of JJG - 547 - 88the dust particle counter verification regulation requirements |
| Superposition errors | JS - 8921: 1997 Less than one every five minutes |
| Print function | 5%, 2000000Grain/cubic feet |
| Overall size | Cab connect the external printer (Optionally available) |
| Weight | 220×40×120 (mm) |
| 1kg | |
| Adjusting | Traceability to the national association of standard technology (NIST), our company has passed the national metrology standard approval, can be traced back to the Shanghai national institute of metrology measurement technology is available for calibration or third - party national metrology institute for calibration |
| Standard configuration | Suitcase, Charger, Sampling head, Null filter, RS232 connecting line, CD for computer communication software |
| Optional accessories | External printer, professional triangle sampling frame, temperature and humidity sensor |
Download catalog for: