info@aelabgroup.com
QR Code 1
QR Code 2

AELAB SK8800Vet Veterinary Full-Auto Hematology Analyzer | Multi-Species 3-Part WBC Analyzer

The AELAB SK8800Vet Veterinary Full-Auto Hematology Analyzer performs precise 3-part WBC differentiation and 23-parameter CBC testing for multi-species diagnostics. Using electrical resistance for counting and the SFT hemoglobin method, the system ensures accurate measurement with low sample consumption and high throughput for modern veterinary laboratories.
Modles : SK8800Vet
whatsapp Whatsapp

The AELAB SK8800Vet Veterinary Full-Auto Hematology Analyzer is designed for comprehensive animal blood testing across multiple species, including cats, dogs, horses, rodents, livestock, and laboratory animals. The system integrates 3-part WBC differentiation, 23 measurement parameters, and histogram analysis, providing a reliable CBC platform for veterinary clinics and research facilities.

With electrical resistance counting and SFT hemoglobin measurement, the SK8800Vet ensures stable analytical performance with low sample consumption and efficient workflow operation. Its 8.4” color TFT interface supports simultaneous parameter display with Windows-based intuitive control.

 

⚙️ Design & Construction

The AELAB SK8800Vet incorporates an advanced valve system and long-life analytical components to ensure stable performance during continuous operation. The system uses electrical resistance sensors for cell counting and a dedicated SFT hemoglobin measurement channel. The enclosure houses an 8.4” TFT display, integrated thermal printer, automatic probe cleaning (inside and outside), and RS232 communication ports.

 

🔬 Working Principle / Testing Method

The analyzer quantifies WBC, RBC, and PLT using electrical resistance technology, while hemoglobin is determined using the cyanide method and SFT method for enhanced stability. Sample aspiration is precisely regulated (9.6 µL for venous/capillary mode and 20 µL for pre-diluted mode). Automatic dilution, mixing, rinsing, and clog-clearing functions ensure reproducible results across all animal types.

 

💡 Key Advantages

  • Pre-programmed for 10 animal species plus 5 user-defined profiles
  • High throughput of more than 35 samples per hour for busy veterinary labs
  • Up to 100000 results with histograms stored for long-term data management
  • Auto-sleeping and wake-up functions for 24-hour operation
  • Low sample volume requirement minimizes stress during animal blood collection
  • Advanced clog detection and auto-cleaning improve reliability
  • Built-in thermal printer with optional external printer support

 

🔗 Connectivity & Integration

The SK8800Vet includes RS232 ports for PC connection, parallel printer support, and compatibility with graphical printing formats. Data management includes storage for up to 100000 results with histograms, ensuring GLP-compliant recordkeeping.

 

🧠 Model Insight

Model Specifications
SK8800Vet 3-part WBC differentiation, 23 parameters, 9.6 µL sample volume, >35 tests/hour, 100000-result storage, 33×38×43 cm, 20 kg

 

🧪 Testing Applications

The AELAB SK8800Vet is suitable for veterinary diagnostic centers, animal hospitals, breeding facilities, livestock screening, laboratory animal research, and wildlife rehabilitation centers. It supports CBC measurement for small animals, companion animals, livestock, and exotic species.

 

Compliance & Quality Assurance

The analyzer incorporates QC modes including X-B, L-J, X, SD, and CV% analysis. All components follow AELAB manufacturing standards with calibration traceability and vet-laboratory quality protocols.

 

Specifications :

Animal Type Cat, dog, horse, mouse, rat, rabbit, pig, cow, monkey, sheep, plus 5 user-defined animal settings
Methodology Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
Parameter 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)
Work mode Single Channel + unique Hemoglobin test system
Sample volume 9.6 µL for Venous and capillary mode, 20 µL for pre-diluted mode
Throughput More than 35 samples per hour, operate 24 hours a day, auto sleeping and waking-up functions
Storage Up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data
Operation language English
QC control X-B, L-J, X, SD, CV %
Reference Value Setting Male, Female, Children, Neonate
Alarm 25 test of alert messages
Input / output RS232, parallel printer and keyboard
Print Graphic thermal printer with various printing format, optional external printer
Temperature 18°C – 30°C, wet ≤ 10–90%
Power supply 220 V ±22 VAC, 50±1 Hz
Dimension 33 CM (L) * 38 CM (W) * 43 CM (H)
Weight 20 KG
Animal Type Cat, dog, horse, mouse, rat, rabbit, pig, cow, monkey, sheep, plus 5 user-defined animal settings
Methodology Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
Parameter 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)
Work mode Single Channel + unique Hemoglobin test system
Sample volume 9.6 µL for Venous and capillary mode, 20 µL for pre-diluted mode
Throughput More than 35 samples per hour, operate 24 hours a day, auto sleeping and waking-up functions
Storage Up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data
Operation language English
QC control X-B, L-J, X, SD, CV %
Reference Value Setting Male, Female, Children, Neonate
Alarm 25 test of alert messages
Input / output RS232, parallel printer and keyboard
Print Graphic thermal printer with various printing format, optional external printer
Temperature 18°C – 30°C, wet ≤ 10–90%
Power supply 220 V ±22 VAC, 50±1 Hz
Dimension 33 CM (L) * 38 CM (W) * 43 CM (H)
Weight 20 KG

Frequently Asked Questions

1Which animal species are supported by the AELAB SK8800Vet?
It supports cats, dogs, horses, mice, rats, rabbits, pigs, cows, monkeys, sheep, plus 5 user-defined species.
2What testing methodology does the SK8800Vet use?
It uses electrical resistance for cell counting and the hemoglobin cyanide method with SFT technology for hemoglobin measurement.
3How many results can the analyzer store?
Up to 100000 sample results including WBC, RBC, and PLT histograms.
4What is the analyzer’s sample volume requirement?
9.6 µL for venous/capillary mode and 20 µL for pre-diluted mode.
5Does the SK8800Vet support automated cleaning?
Yes, it includes automatic sample probe cleaning inside and outside, with mixing, rinsing, and clog-clearing functions.

Request Quote: AELAB SK8800Vet Veterinary Full-Auto Hematology Analyzer | Multi-Species 3-Part WBC Analyzer