The SK3002B1 Semi-Auto Chemistry Analyzer is a versatile laboratory tool for efficient biochemical testing. It supports multiple test methods, including kinetic, end-point, two-point, turbidimetry, and absorbance, with 7 wavelength filters (340-630 nm) for diverse assays. The 7-inch color LCD touchscreen provides intuitive operation, while 10 incubators at 37°C ± 0.3°C and 3 timers ensure precise control over test conditions.
Pre-programmed with 112 test items, the analyzer can handle various biochemical analyses. It supports both flow cell and cuvette test modes and displays real-time curves for monitoring progress. The analyzer has 10,000 sample result storage capacity and a light source hibernate function to prolong lamp life. It also features RS232 connectivity for easy integration with PC systems.
Ideal for clinical and research labs, the SK3002B1 supports multiple languages, including English, French, Spanish, Portuguese, Indonesian, and Russian, making it a global solution for high-accuracy testing.
Feature:
✅ 🔍 Recommended Models by Use Case
📌 Choose the Right Model for Your Lab Setting
SK3002B1 – Best for small to mid-sized clinical labs, offering a wide range of assays and compact footprint.
Educational Institutions – Ideal for training students in biochemical testing with intuitive touch interface and visual real-time curves.
Research Facilities – Supports custom method development and quality control curves, meeting advanced scientific needs.
Quality Control Departments – Excellent repeatability (CV <1%) ensures reliable QC outcomes for production labs.
✅ 🧪 Ideal For
🔬 A Versatile Choice for Biochemical Analysis
Clinical diagnostic laboratories
Research institutes
Pharmaceutical QC labs
Food safety and agricultural labs
University and college teaching labs
Veterinary and pathology labs
Common test categories include:
Liver Function: ALT, AST, ALP, T-BIL
Renal Function: BUN, CRE, UA
Cardiac Markers: CK, CK-MB, LDH
Lipids: HDL-C, LDL-C, T-CHO
Glucose & Hemoglobin: GLU, HGB
Immune Proteins: IGA, IGG, IGM
✅ ❓ FAQ – Lab-Focused
Q: How is calibration performed on the SK3002B1?
A: The analyzer allows manual and automatic calibration using quality control curves (SD, CV%, L-J) for each test item. Built-in software guides users through the calibration process.
Q: Is this analyzer GMP compliant?
A: While the device supports traceable QC and standardization features, GMP compliance depends on how it’s implemented in your lab environment and validated according to GMP protocols.
Q: What is the warranty period?
A: The SK3002B1 comes with a standard 1-year manufacturer warranty, covering parts and service under normal lab operating conditions.
Q: Can it connect to external LIS or PCs?
A: Yes, the analyzer includes an RS232 interface for direct integration with laboratory information systems or PC data management tools.
Q: Does it support multiple languages?
A: Yes, it includes English, French, Spanish, Portuguese, Indonesian, and Russian, making it ideal for international and multilingual lab environments.
Specifications :
| Test mode | Kinetic, End-point, Fixed-time, Turbidimetry , Absorbance |
| Wavelength | 7 standard filters, 340, 405, 492, 510, 546, 578, 630 nm, 1 free position |
| Wavelength precision | ±2 nm, width ≤ 10nm |
| Absorbance range | 0~4.500 Abs |
| Absorbance Resolution | outside 0.0001 Abs , inside 0.00001 Abs |
| Carry over | < 1% |
| Repeatability CV | < 1% |
| Incubator | 37℃、30℃、25℃、Precision : ±0.1℃ |
| Sample volume | 0~3000 uL (≥500uL recommend) |
| Data Storage | ≥10000 |
| Quality control curve | 、SD、CV%、L-J quality control curve for every test item |
| Flow cell | 32 uL quartz glass, 10 mm |
| Lamp | Philips 6V 10W Halogen Lamp with long life |
| Screen | 7 inch color LCD |
| CPU | ARM series high speed micro CPU |
| Printer | Internal thermal sensitive printer |
| Interface | RS-232 |
| Work Environment | Temperature 0℃ ~ 40℃, Humidity: ≤80% |
| Power supply | 100~240VAC,50-60Hz,100VA |
| Dimension | 340(L)*270(W)*160(H) |
| Weight | 5 kg |
Usual Test List :
| Liver function | ALT AST ALP T-BIL D-BIL TP ALB TTT CHE Nh3 |
| Renal function | BUN CRE UA URE CO2-CP γ-GT |
| Lipids | T-CHO TG HDL-C LDL-C |
| Cardiac function | CK CK-MB LDH |
| Immune proteins | IGA IGG IGM C3 |
| Others | GLU HGB AMS |
| Test mode | Kinetic, End-point, Fixed-time, Turbidimetry , Absorbance |
| Wavelength | 7 standard filters, 340, 405, 492, 510, 546, 578, 630 nm, 1 free position |
| Wavelength precision | ±2 nm, width ≤ 10nm |
| Absorbance range | 0~4.500 Abs |
| Absorbance Resolution | outside 0.0001 Abs , inside 0.00001 Abs |
| Carry over | < 1% |
| Repeatability CV | < 1% |
| Incubator | 37℃、30℃、25℃、Precision : ±0.1℃ |
| Sample volume | 0~3000 uL (≥500uL recommend) |
| Data Storage | ≥10000 |
| Quality control curve | 、SD、CV%、L-J quality control curve for every test item |
| Flow cell | 32 uL quartz glass, 10 mm |
| Lamp | Philips 6V 10W Halogen Lamp with long life |
| Screen | 7 inch color LCD |
| CPU | ARM series high speed micro CPU |
| Printer | Internal thermal sensitive printer |
| Interface | RS-232 |
| Work Environment | Temperature 0℃ ~ 40℃, Humidity: ≤80% |
| Power supply | 100~240VAC,50-60Hz,100VA |
| Dimension | 340(L)*270(W)*160(H) |
| Weight | 5 kg |
Usual Test List :
| Liver function | ALT AST ALP T-BIL D-BIL TP ALB TTT CHE Nh3 |
| Renal function | BUN CRE UA URE CO2-CP γ-GT |
| Lipids | T-CHO TG HDL-C LDL-C |
| Cardiac function | CK CK-MB LDH |
| Immune proteins | IGA IGG IGM C3 |
| Others | GLU HGB AMS |