info@aelabgroup.com
QR Code 1
QR Code 2

AELAB Professional pH/ORP/Ion Meter A120/130/131 – Precision Lab Testing

The AELAB A120/130/131 Professional pH/ORP/Ion Meter series delivers high-precision measurements for pH, ORP, ion concentration, and water hardness. Engineered for laboratory and field applications, it features multi-point calibration, ATC, advanced data management, and user-friendly automation—ensuring reliable results for professional lab users.

Modles : A120~A130~A131
whatsapp Whatsapp

The A120/130/131 Professional pH/ORP/Ion Meter offers accurate and versatile measurement for pH, ORP, ion concentration, and water hardness. It supports 1 to 5-point calibration with auto-buffer recognition for pH, ensuring ease of use and reliable results. Automatic Temperature Compensation (ATC) ensures accurate pH readings across varying conditions. The meter also provides 1-point ORP calibration, and features selectable ion measurement methods and multiple concentration units. For water hardness, it supports 2 to 5-point calibration with several unit options.

Other key features include a Stability Indicator, Auto-Read function, Interval Readings for automated data transfer, and USB connectivity. Password protection secures calibration settings, while Calibration Due Reminder helps maintain consistent performance. The device also has a Reset feature to restore factory settings. Ideal for professionals, it’s designed for precise and efficient testing in labs and field applications.

 

Features:

pH:
  • 1 to 5 points push-button calibration with auto-buffer recognition.
  • Selectable pH buffer group (USA/NIST/DIN) or using custom calibration solutions.
  • Calibration Due Reminder prevents the unused calibration and settings.
  • Automatic Temperature Compensation provides accurate reading over the entire pH range.
  • Solution Temperature Coefficient compensates for the pure water samples and references the pH to 25°C.
  • Limit alarm alerts when reading exceeds range.
ORP:
  • 1 point offset calibration allows adjusting the displayed value to a known standard.
  • Relative and absolute millivolt modes provide the reliable ORP measurements.
ION:
  • Selectable ion measurement methods, including the direct reading, known addition, known subtraction, sample addition and sample subtraction.
  • Selectable concentration units, including the ppm, mg/L, µmol/L and mmol/L.
  • 1 to 5 points calibration for accurate ion concentration measurements.
  • Automatically recognizes the ion selective electrodes; does not need to specify type of ion.
  • Electrode management is capable of storing the 3 slopes and recalling the calibration data of each electrode.
  • Calibration report provides the details of the calibration standard and slope.
WATER HARDNESS:
  • 2 to 5 points calibration from low to high concentrations.
  • Selectable measurement units (German degree, English degree, French degree, mg/L and mmol/L) are used for professional water hardness measurements.
GENERAL:
  • Calibration Due Reminder prompts user to calibrate the meter regularly.
  • Stability indicator shows when a measurement is recognized as stable.
  • Auto-Read feature senses and locks the measurement endpoint.
  • Interval Readings automatically send the measurement data to the computer or printer.
  • Password protection prevents the unauthorized calibration and settings.
  • Stored readings can be transferred into the computer by USB communication interface.
  • Reset feature automatically resumes all settings back to factory default options.

 

🔬 How It Works?
This professional meter utilizes advanced electrode-based sensing to provide real-time, high-accuracy measurement. The pH function uses auto-buffer recognition and ATC to ensure calibration reliability. The ORP function includes relative and absolute modes with 1-point offset calibration. For ion and hardness testing, the device supports advanced methods (known addition/subtraction, sample addition/subtraction) and automatically detects ion-selective electrodes. Data is securely stored and transferred via USB, with the Auto-Read and Stability Indicator guaranteeing consistent readings.

 

💡 Advantages

  • 🔁 Multi-parameter Capability: Consolidates pH, ORP, ion, and hardness tests in one unit

  • Accurate & Reliable: ±0.002 pH accuracy and up to 5-point calibration

  • 🔐 Secure Operation: Password protection and Calibration Due Reminders

  • 📊 Smart Interface: Auto-Read, Stability Indicator, and interval readings simplify lab work

  • 🔌 Easy Data Handling: USB transfer and calibration reports for documentation

  • 🔄 Reset Option: Restore factory settings instantly for troubleshooting or setup

 

🔍 Recommended Models by Use Case

  • A120: Ideal for academic labs or water testing facilities needing only pH and ORP

  • A130: Best for research institutions and environmental testing needing full-spectrum measurement

  • A131: Suited for high-throughput labs and QC departments focused on ion analysis and hardness

 

🧪 Ideal For

  • Environmental and water quality testing labs

  • Food and beverage industry QC labs

  • Pharmaceutical R&D departments

  • Educational and academic research institutions

  • Industrial process labs requiring ion or hardness control

 

❓ FAQ – Lab-Focused

Q: How is calibration done?
A: Calibration is easy with push-button, 1–5-point calibration. Auto-buffer recognition supports USA, NIST, DIN, or custom buffers.

Q: Is the device GMP compliant?
A: Yes. Features like password protection, calibration logs, and traceability support GMP workflows.

Q: How long is the warranty?
A: AELAB provides a 1-year standard warranty with optional extended coverage.

Specifications :

Model A120 A130 A131
pH Measuring Range -2.000 - 20.000pH --
Accuracy ±0.002pH --
Resolution 0.001, 0.01pH --
Calibration Points 1 - 5 points --
pH Buffer Options USA, NIST, DIN or Custom --
mV Measuring Range ±2000mV --
Accuracy ±0.2mV --
Resolution 0.1mV --
Calibration Points 1 point, only for relative mV mode --
Measurement Modes Relative and Absolute mV --
Ion Measuring Range 0.001 - 30000, depending on the range of ion selective electrode --
Measurement Units ppm, mg/L, mol/L, mmol/L --
Accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent) --
Resolution 0.001, 0.01, 0.1, 1 --
Calibration Points 2 - 5 points --
Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L, mmol/L --
Measurement Methods Direct reading, known addition, known subtraction, sample addition, sample subtraction --
Water Hardness Measuring Range 0.05 - 2000mmol/L, 0 - 1120°fH, 0 - 1404°e, 0 - 2000°TH, 0 - 8000mg/L (Ca²⁺) --
Accuracy ±1% F.S --
Resolution 0.001, 0.01, 0.1, 1 --
Calibration Points 2 - 5 points --
Calibration Solutions 0.01, 0.1, 1, 10, 100mmol/L --
Temperature Measuring Range 0 - 105°C, 32 - 221°F
Accuracy ±0.5°C, ±0.9°F
Resolution 0.1°C, 0.1°F
Calibration Points 1 point
Temperature Compensation 0 - 100°C, 32 - 212°F, Manual or Automatic
General Data Hold Manual or Auto - Endpoint
Stability Criteria Standard or High - accuracy
Interval Readings 10, 30, 60 seconds, 10, 30 minutes or Off
Calibration Due Alarm 1 to 31 days or Off
Memory Stores up to 1000 data sets
Output USB communication interface
Display 7 inch TFT LCD
Power Requirements DC12V/2A power adapter
Dimensions and Weight 240(L)×220(W)×80(H)mm, 1.7kg
Model A120 A130 A131
pH Measuring Range -2.000 - 20.000pH --
Accuracy ±0.002pH --
Resolution 0.001, 0.01pH --
Calibration Points 1 - 5 points --
pH Buffer Options USA, NIST, DIN or Custom --
mV Measuring Range ±2000mV --
Accuracy ±0.2mV --
Resolution 0.1mV --
Calibration Points 1 point, only for relative mV mode --
Measurement Modes Relative and Absolute mV --
Ion Measuring Range 0.001 - 30000, depending on the range of ion selective electrode --
Measurement Units ppm, mg/L, mol/L, mmol/L --
Accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent) --
Resolution 0.001, 0.01, 0.1, 1 --
Calibration Points 2 - 5 points --
Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L, mmol/L --
Measurement Methods Direct reading, known addition, known subtraction, sample addition, sample subtraction --
Water Hardness Measuring Range 0.05 - 2000mmol/L, 0 - 1120°fH, 0 - 1404°e, 0 - 2000°TH, 0 - 8000mg/L (Ca²⁺) --
Accuracy ±1% F.S --
Resolution 0.001, 0.01, 0.1, 1 --
Calibration Points 2 - 5 points --
Calibration Solutions 0.01, 0.1, 1, 10, 100mmol/L --
Temperature Measuring Range 0 - 105°C, 32 - 221°F
Accuracy ±0.5°C, ±0.9°F
Resolution 0.1°C, 0.1°F
Calibration Points 1 point
Temperature Compensation 0 - 100°C, 32 - 212°F, Manual or Automatic
General Data Hold Manual or Auto - Endpoint
Stability Criteria Standard or High - accuracy
Interval Readings 10, 30, 60 seconds, 10, 30 minutes or Off
Calibration Due Alarm 1 to 31 days or Off
Memory Stores up to 1000 data sets
Output USB communication interface
Display 7 inch TFT LCD
Power Requirements DC12V/2A power adapter
Dimensions and Weight 240(L)×220(W)×80(H)mm, 1.7kg

Request Quote: AELAB Professional pH/ORP/Ion Meter A120/130/131 – Precision Lab Testing