AELAB 980 Laboratory Dissolved Oxygen Meter – Precision DO Measurement for Water Analysis

The AELAB 980 Laboratory Dissolved Oxygen Meter is engineered for precise measurement of dissolved oxygen and % saturation in water. Designed for laboratories, this advanced DO meter offers barometric and salinity compensation, 1–2 point calibration, and USB data export—ideal for research, environmental testing, and quality control.
Modles : 980
whatsapp Whatsapp

The Laboratory Dissolved Oxygen Meter 980 is a high-precision instrument designed for measuring dissolved oxygen concentration and % saturation of oxygen in water. It offers 1 or 2-point calibration using air-saturated water or a zero-oxygen solution, ensuring accurate results. The meter compensates for salinity and barometric pressure, making it ideal for diverse environmental conditions.

With selectable units like mg/L, ppm, mmHg, and kPa, the 980 meter provides flexibility in measurement reporting. Automatic Temperature Compensation (ATC) ensures stable readings across varying temperatures. The Auto-Hold function locks in stable readings, while the stability indicator ensures only reliable measurements are recorded.

Users are reminded to regularly calibrate via the Calibration Due Reminder. The expanded memory can store up to 100 data sets, which can be transferred to a computer via the USB interface for further analysis. The setup menu allows customization of up to 9 parameters, including calibration points, resolution, and stability criteria. The meter also features a reset function to restore factory settings for ease of use.

Included are a dissolved oxygen probe, membrane cap, electrolyte solution, electrode holder, and power adapter, making the 980 meter a comprehensive and reliable tool for laboratory dissolved oxygen measurements.

 

Feature:

  • 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
  • Salinity and barometric pressure compensations provide the reliable measuring results.
  • Selectable measurement units, including the mg/L, ppm, mmHg and kPa.
  • Automatic Temperature Compensation provides accurate reading over the entire range.
  • Calibration Due Reminder prompts user to calibrate the meter regularly.
  • Stability indicator shows when a measurement is recognized as stable.
  • Auto-Hold feature senses and locks the measurement endpoint.
  • Setup menu allows setting the 9 parameters, including the number of calibration points, resolution, stability criteria, etc.
  • Reset feature automatically resumes all settings back to factory default options.
  • Expanded memory stores and recalls up to 100 data sets.
  • Stored readings can be transferred into the computer by USB communication interface.

 

🧩 Recommended Models by Use Case 💡

  • AELAB 980 – Best for standard lab-based water quality monitoring in academic, environmental, and industrial labs.

  • AELAB 980 Pro Kit (if applicable) – Ideal for field professionals needing enhanced portability with protective casing and calibration kits.

  • AELAB Multi-Meter Series (if cross-sell option exists) – For labs requiring pH, conductivity, and DO in a single device.

 

🎯 Ideal For – Who Should Use It? 👩‍🔬

  • Environmental Scientists – Measuring DO in rivers, lakes, or wastewater.

  • Academic & Research Labs – Accurate dissolved oxygen analysis in aquatic biology studies.

  • Industrial Water Quality Teams – Ensuring DO levels in effluents or process water.

  • Aquaculture & Fishery Research – Monitoring oxygen saturation for optimal aquatic life support.

 

FAQ – Lab-Focused Answers 📘

Q1: Can I use the AELAB 980 for marine or brackish water samples?
Yes, the salinity compensation function (0–50 g/L) allows for accurate measurements in saline environments.

Q2: How often should I calibrate the meter?
The built-in Calibration Due Reminder lets you schedule alerts between 1–31 days to maintain optimal accuracy.

Q3: Can the data be saved and analyzed on a computer?
Absolutely. The AELAB 980 features USB output to transfer up to 500 stored readings for further analysis or reporting.

Q4: Is the probe replaceable or serviceable?
Yes. The DO probe comes with a replaceable membrane cap and electrolyte solution, both included in the package.

Q5: Does it support temperature compensation?
Yes, it features full Automatic Temperature Compensation (ATC) for stable readings in varying thermal conditions.

Specifications :

Model 980
DO - Measuring Range 0.00–20.00mg/L
DO - Accuracy ±0.2mg/L
DO - Resolution 0.01, 0.1mg/L
% Saturation - Measuring Range 0.0–200.0%
% Saturation - Accuracy ±2.0%
% Saturation - Resolution 0.1, 1%
% Saturation - Calibration Points 1 or 2 points
General - Temperature Compensation 0–50°C, 32–122°F, Automatic
General - Barometric Pressure Correction 60.0–125.5kPa, 450–850mmHg
General - Salinity Correction 0–50g/L
General - Data Hold Manual or Auto-Endpoint
General - Calibration Due Alarm 1 to 31 days or Off
General - Memory Stores up to 500 data sets
General - Output USB communication interface
General - Power Requirements DC5V, using AC Adapter, 220VAC/50Hz
General - Dimensions and Weight 210(L)×188(W)×60(H)mm, 1.5kg
Model 980
DO - Measuring Range 0.00–20.00mg/L
DO - Accuracy ±0.2mg/L
DO - Resolution 0.01, 0.1mg/L
% Saturation - Measuring Range 0.0–200.0%
% Saturation - Accuracy ±2.0%
% Saturation - Resolution 0.1, 1%
% Saturation - Calibration Points 1 or 2 points
General - Temperature Compensation 0–50°C, 32–122°F, Automatic
General - Barometric Pressure Correction 60.0–125.5kPa, 450–850mmHg
General - Salinity Correction 0–50g/L
General - Data Hold Manual or Auto-Endpoint
General - Calibration Due Alarm 1 to 31 days or Off
General - Memory Stores up to 500 data sets
General - Output USB communication interface
General - Power Requirements DC5V, using AC Adapter, 220VAC/50Hz
General - Dimensions and Weight 210(L)×188(W)×60(H)mm, 1.5kg

Request Quote: AELAB 980 Laboratory Dissolved Oxygen Meter – Precision DO Measurement for Water Analysis