info@aelabgroup.com
QR Code 1
QR Code 2

AELAB Class II A2 Biological Safety Cabinet – BSC Series

The AELAB Class II A2 BSC Series Biological Safety Cabinet delivers enhanced protection for lab professionals working in microbiological and biomedical settings. Equipped with a motorized front window, HEPA filtration, and intelligent airflow controls, it ensures safe, sterile, and efficient workflows. Ideal for research, clinical, and quality control labs.

Modles : BSC-1100IIA2-X~BSC-1300IIA2-X~BSC-1500IIA2-X~BSC-1800IIA2-X~BSC-2000IIA2-X
whatsapp Whatsapp

The Class II A2 BSC Series Biological Safety Cabinet offers advanced protection and user-friendly features for laboratory environments. It includes a motorized front window with foot switch control, allowing hands-free adjustments to reduce airflow disturbance. The cabinet automatically adjusts air speed in response to filter blockages and retains settings after a power failure with its memory function. Safety is enhanced with audio-visual alarms for abnormal airflow, unsafe window height, and filter replacement. HEPA and UV lamp life indicators support timely maintenance. A remote control enables full operation from a distance, while interlock functions prevent unsafe combinations like the UV lamp operating with the window open. Surrounded by negative pressure, the work area ensures maximum containment and user safety.

 

Features:

  • Motorized front window.
  • Time reserve function.
  • HEPA filter life and UV life indicator.
  • Automatic air speed adjustable with filter block.
  • With memory function in case of power-failure.
  • Audio and visual alarm (Abnormal airflow velocity; Filter replacement; Front window at unsafe height).
  • Work area surrounded by negative pressure, it can ensure maximum safety in work area.
  • Audio and visual alarm (Filter replacement, window over height, abnormal air flow velocity etc).
  • Remote control: all functions can be realized with it, making the operation much easier and more convenient.
  • Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; blower and front window.
  • Foot switch: adjust front window height by foot during experiment, to avoid airflow turbulence caused by arm movement.

 

✅ 🔬 How It Works?

The AELAB Class II A2 Biological Safety Cabinet operates using a 70/30 airflow system: 70% of air is recirculated through high-efficiency HEPA filters, while 30% is safely exhausted. The negative pressure work zone and front sash window contain airborne contaminants. A motorized sash, controlled via foot switch or remote, allows hands-free operation to reduce disturbance. The onboard microprocessor adjusts airflow speed in real time based on filter resistance and environmental changes, ensuring consistent Class II containment performance.

 

✅ 💡 Advantages

  • Advanced Containment: Dual HEPA filters with 99.9995% efficiency ensure particle-free air.

  • Hands-Free Control: Motorized sash with foot switch and remote control improves user convenience.

  • Intelligent Monitoring: Real-time air velocity, filter status, and lamp life indicators on LCD display.

  • Smart Safety: Interlock systems prevent unsafe operations between UV lamp, blower, and sash.

  • Power-Failure Memory: Auto-resume with saved settings protects workflow during outages.

  • Quiet Operation: Noise levels meet global standards for lab comfort (EN12469 & NSF49 compliant).

 

✅ 🔍 Recommended Models by Use Case

  • BSC-1100IIA2-X / BSC-1300IIA2-X – Best for educational labs and compact research workspaces.

  • BSC-1500IIA2-X – Ideal for hospital microbiology and biosafety testing.

  • BSC-1800IIA2-X – Perfect for pharmaceutical and chemical quality control labs.

  • BSC-2000IIA2-X – Designed for high-throughput testing and industrial R&D environments.

 

✅ 🧪 Ideal For

  • Clinical & Diagnostic Labs

  • Biomedical & Genetic Research

  • Food Safety Testing Labs

  • Chemical & Microbiological Analysis

  • Educational & Training Institutions

  • GMP-Compliant Cleanroom Environments

Specifications :

Model BSC-1100IIA2-X BSC-1300IIA2-X BSC-1500IIA2-X BSC-1800IIA2-X BSC-2000IIA2-X
Internal Size(W*D*H) 940* 600*660 mm 1150*600*660 mm 1350*600*660mm 1625*600*660mm 1800*600*660mm
External Size(W*D*H) 1100*750*2250mm 1300*750*2250mm 1500*750*2250mm 1800*775*2290mm 1950*800*2170mm
Tested Opening Safety Height = 200 mm(8'')
Max Opening 420mm(17’’) 420mm(17’’) 500mm(20’’) 550mm(22’’) 400mm(16’’)
Inflow Velocity 0.53±0.025 m/s
Downflow Velocity 0.33±0.025 m/s
HEPA  Filter Two, 99.9995% efficient at 0.12um. Filter life indicator.
Front Window Motorized. Two-layer laminated toughened glass ≥ 5mm. Anti UV.
Noise EN12469 ≤ 58 dB / NSF49 ≤ 61 dB
UV Lamp 30W*1 30W* 1 40W* 1 40W*1 40W* 1
  UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination.
Illuminating Lamp LED Lamp
  12W*2 12W*2 16W*2 16W*2 16W*2
Illumination ≥1000Lux
Consumption 760W 800W 900W 900W 1500W
Waterproof Sockets Two, total load of two sockets: 500W
Display LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.
Control System Microprocessor
Airflow System 70% air recirculation, 30% air exhaust
Visual and audio alarm Abnormal airflow velocity,Filter replacement, front window at unsafe height,.
Material Work Zone: 304 stainless steel
  Main Body: Cold-rolled steel with anti-bacteria powder coating.
Work Surface Height 750mm
Caster Footmaster caster
Power Supply AC220V±10%, 50/60Hz; 110V±10%, 60Hz
Standard Accessory LED lamp, UV lamp*2, Base stand, Remote control, Foot switch, Drain valve, Waterproof sockets*2
Optional Accessory Water and gas tap, Electric height adjustable base stand.
Gross Weight 243kg 280kg 316kg 395kg 420kg
Package Size(W*D*H) 1220× 1000× 1840 mm 1460*1050*1800 mm 1630*1000*1820 mm 1930*1000*1820mm 2090*1050*1860 mm
Model BSC-1100IIA2-X BSC-1300IIA2-X BSC-1500IIA2-X BSC-1800IIA2-X BSC-2000IIA2-X
Internal Size(W*D*H) 940* 600*660 mm 1150*600*660 mm 1350*600*660mm 1625*600*660mm 1800*600*660mm
External Size(W*D*H) 1100*750*2250mm 1300*750*2250mm 1500*750*2250mm 1800*775*2290mm 1950*800*2170mm
Tested Opening Safety Height = 200 mm(8'')
Max Opening 420mm(17’’) 420mm(17’’) 500mm(20’’) 550mm(22’’) 400mm(16’’)
Inflow Velocity 0.53±0.025 m/s
Downflow Velocity 0.33±0.025 m/s
HEPA  Filter Two, 99.9995% efficient at 0.12um. Filter life indicator.
Front Window Motorized. Two-layer laminated toughened glass ≥ 5mm. Anti UV.
Noise EN12469 ≤ 58 dB / NSF49 ≤ 61 dB
UV Lamp 30W*1 30W* 1 40W* 1 40W*1 40W* 1
  UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination.
Illuminating Lamp LED Lamp
  12W*2 12W*2 16W*2 16W*2 16W*2
Illumination ≥1000Lux
Consumption 760W 800W 900W 900W 1500W
Waterproof Sockets Two, total load of two sockets: 500W
Display LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.
Control System Microprocessor
Airflow System 70% air recirculation, 30% air exhaust
Visual and audio alarm Abnormal airflow velocity,Filter replacement, front window at unsafe height,.
Material Work Zone: 304 stainless steel
  Main Body: Cold-rolled steel with anti-bacteria powder coating.
Work Surface Height 750mm
Caster Footmaster caster
Power Supply AC220V±10%, 50/60Hz; 110V±10%, 60Hz
Standard Accessory LED lamp, UV lamp*2, Base stand, Remote control, Foot switch, Drain valve, Waterproof sockets*2
Optional Accessory Water and gas tap, Electric height adjustable base stand.
Gross Weight 243kg 280kg 316kg 395kg 420kg
Package Size(W*D*H) 1220× 1000× 1840 mm 1460*1050*1800 mm 1630*1000*1820 mm 1930*1000*1820mm 2090*1050*1860 mm

Frequently Asked Questions

1How is calibration performed on this cabinet?
Calibration should be conducted by certified technicians using anemometers to verify inflow and downflow velocities. Filter integrity tests should also be done regularly.
2Is the cabinet GMP compliant?
Yes, the AELAB BSC Series adheres to GMP standards and international biosafety requirements such as EN12469 and NSF49.
3How long is the warranty?
The cabinet comes with a 1-year standard warranty. Extended warranties are available upon request.
4Can the cabinet be used for cytotoxic drug preparation?
This model is not designed for handling cytotoxic drugs. For that purpose, a Class II Type B2 or a cytotoxic-specific cabinet is recommended.

Request Quote: AELAB Class II A2 Biological Safety Cabinet – BSC Series