The AELAB DS-810N/DS-812N/DS-816N benchtop liquid colorimeter provides more than 30 color indicators, including platinum cobalt index, Gardner, Saybolt, China, the United States, and European Pharmacopoeia standards. Intelligent zero calibration ensures accurate measurement of △E*ab≤0.01.
The minimum liquid addition is reduced to 1 ml; 10 mm and 50 mm cuvets are standard, and 33 mm and 100 mm cuvets are optional. The measurement speed is fast, and a single measurement takes only 1.5 seconds. The thermostatic sample tank (up to 90 °C) design ensures sample fluidity, and the 7-inch touch screen stores more than 100,000 pieces of data.
The AELAB DS-812N integrates a Φ40 mm integrating sphere with Avian-D fully diffuse surface coating and CLEDs (Full Band Balanced Led Light Source). A dual optical sensor array sensor acquires transmission data. DS-816N supports stand-alone operation with a thermostatic sample tank for measurements up to 90 °C.
The DS Series quantifies liquid color using a d/0 optical geometry with 0° viewing angle over a 360–780 nm wavelength range at 10 nm interval and 5 nm half-band width. Results include CIE Lab/LCh/Luv, XYZ, Yxy, transmissibility, Hunter Lab, Munsell, MI, and CMYK spaces. Color difference formulas supported are ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*94, and ΔE*00. Observation light sources include A, B, C, D50/D55/D65/D75 and an extended LED/CWF/U-series set for application matching.
Software support includes ColorExpert and Color QC2 for laboratory data management and quality control reporting. DS-812N provides audit trail capability (as required by FDA and CFDA) for regulated environments.
| Model | Key Specifications |
|---|---|
| DS-810N | ΔE*ab repeatability ≤0.015 (max ≤0.04); Interstation error ΔE*ab < 0.25; Stand-alone operation: / |
| DS-812N | 7 inch capacitive touch screen; Over 100,000 pieces of data; Audit trail Yes (as required by FDA and CFDA); Intelligent zero calibration |
| DS-816N | Heating function: yes; Heating range: ambient to 90 °C; Stand-alone operation: Support; ΔE*ab repeatability ≤0.01 (max ≤0.03); Interstation error ΔE*ab < 0.2 |
The AELAB DS Series measures liquid color for pharmaceutical solutions (Chinese, European, and United States Pharmacopoeia), petrochemical and fuel grades (Gardner, Saybolt, ASTM Color), water and solvents (APHA/Hazen, Pt-Co), beverage quality (EBC Beer Color), and sugars (ICUMSA). It also reports WI, YI, Tint, and isochromic metrics for materials research and production QA.
Measurements follow d/0 geometry and comply with CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c, and relevant ASTM methods (D1209, D5386, D6045, D6166, D1502). AELAB quality control supports GLP-style traceability with audit trail on DS-812N.
For rigorous liquid color control, the AELAB DS-810N, DS-812N, and DS-816N deliver fast, repeatable results across laboratory and industrial workflows.
Specifications :
| Model | DS-810N | DS-812N | DS-816N |
|---|---|---|---|
| Measurement condition | d/0(scattered light source, 0 degree viewing Angle) Comply with CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c, ASTM D1209, ASTM D5386, ASTM D6045, ASTM D6166, ASTM D1502 | ||
| Stand-alone operation | / | Support | |
| Integrating sphere | Φ40mm, Avian-D fully diffuse surface coating | ||
| Lighting source | CLEDs(Full Band Balanced Led Light Source) | ||
| Inductor | Dual optical sensor array sensor | ||
| Wavelength range | 360-780nm | ||
| Wavelength interval | 10nm | ||
| Half-band width | 5nm | ||
| Measuring range | 0~200% | ||
| Resolution | 0.0001 | ||
| Observer Angle | 2°/10° | ||
| Observation light source | A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83, TL84,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V4 | ||
| Reveal | Pharmacopoeia color number, transmission map/data, sample chromaticity value, color difference value/map, pass/fail result, color bias, color simulation, color simulation Historical data color simulation, standard sample manual input, test report | ||
| Measuring time | ≤1.5 seconds | ||
| Measuring optical path | Standard: 10mm glass colorimetric dish, 50mm glass colorimetric dish (optional 33mm and 100mm glass colorimetric dish) | ||
| Color space | CIE Lab,LCh,CIE Luv,XYZ,Yxy, transmissibility, Hunter Lab Munsell, MI,CMYK | ||
| Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00 | ||
| Other indicators | Pharmacopoeia (Chinese Pharmacopoeia, European Pharmacopoeia, The United States pharmacopoeia), WI (ASTM E313-20, ASTM E313-73, CIE, ISO2470 / R457, Hunter, Taube Berger Shesny), YI (ASTM D1925, ASTM E313-20, ASTM E313-73), Tint(ASTM E313-20), Isochromic Index Mim, APHA, Hazen, Pt-Co (platinum-cobalt index), Gardner (Gardner Index), Iron-Cobalt Index,Saybolt (Saybolt Index), ASTM Color,EBC (Beer Color), ICUMSA Color(sugar color) | ||
| Repeatability * | Transmittance: standard deviation ≤0.08% Colorimetric value: ΔE*ab≤0.015 standard deviation, maximum ≤0.04 |
Transmittance: standard deviation ≤0.08% Chroma value: ΔE*ab≤0.01 standard deviation, maximum ≤0.03 |
|
| Interstation error | ΔE*ab < 0.25 | ΔE*ab < 0.2 | |
| Heating function | / | yes | |
| Heating temperature range | / | From ambient temperature to 90℃ | |
| Audit trail | / | Yes (as required by FDA and CFDA) | |
| Special function | Intelligent zero calibration | ||
| Screen size | / | 7 inch capacitive touch screen | |
| Store data | Over 100,000 pieces of data | ||
| Software support | ColorExpert, Color QC2 | ||
* After correction, measure the air standard deviation and maximum 30 times at an interval of 5s
| Model | DS-810N | DS-812N | DS-816N |
|---|---|---|---|
| Measurement condition | d/0(scattered light source, 0 degree viewing Angle) Comply with CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c, ASTM D1209, ASTM D5386, ASTM D6045, ASTM D6166, ASTM D1502 | ||
| Stand-alone operation | / | Support | |
| Integrating sphere | Φ40mm, Avian-D fully diffuse surface coating | ||
| Lighting source | CLEDs(Full Band Balanced Led Light Source) | ||
| Inductor | Dual optical sensor array sensor | ||
| Wavelength range | 360-780nm | ||
| Wavelength interval | 10nm | ||
| Half-band width | 5nm | ||
| Measuring range | 0~200% | ||
| Resolution | 0.0001 | ||
| Observer Angle | 2°/10° | ||
| Observation light source | A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83, TL84,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V4 | ||
| Reveal | Pharmacopoeia color number, transmission map/data, sample chromaticity value, color difference value/map, pass/fail result, color bias, color simulation, color simulation Historical data color simulation, standard sample manual input, test report | ||
| Measuring time | ≤1.5 seconds | ||
| Measuring optical path | Standard: 10mm glass colorimetric dish, 50mm glass colorimetric dish (optional 33mm and 100mm glass colorimetric dish) | ||
| Color space | CIE Lab,LCh,CIE Luv,XYZ,Yxy, transmissibility, Hunter Lab Munsell, MI,CMYK | ||
| Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00 | ||
| Other indicators | Pharmacopoeia (Chinese Pharmacopoeia, European Pharmacopoeia, The United States pharmacopoeia), WI (ASTM E313-20, ASTM E313-73, CIE, ISO2470 / R457, Hunter, Taube Berger Shesny), YI (ASTM D1925, ASTM E313-20, ASTM E313-73), Tint(ASTM E313-20), Isochromic Index Mim, APHA, Hazen, Pt-Co (platinum-cobalt index), Gardner (Gardner Index), Iron-Cobalt Index,Saybolt (Saybolt Index), ASTM Color,EBC (Beer Color), ICUMSA Color(sugar color) | ||
| Repeatability * | Transmittance: standard deviation ≤0.08% Colorimetric value: ΔE*ab≤0.015 standard deviation, maximum ≤0.04 |
Transmittance: standard deviation ≤0.08% Chroma value: ΔE*ab≤0.01 standard deviation, maximum ≤0.03 |
|
| Interstation error | ΔE*ab < 0.25 | ΔE*ab < 0.2 | |
| Heating function | / | yes | |
| Heating temperature range | / | From ambient temperature to 90℃ | |
| Audit trail | / | Yes (as required by FDA and CFDA) | |
| Special function | Intelligent zero calibration | ||
| Screen size | / | 7 inch capacitive touch screen | |
| Store data | Over 100,000 pieces of data | ||
| Software support | ColorExpert, Color QC2 | ||
* After correction, measure the air standard deviation and maximum 30 times at an interval of 5s