The AELAB GC-MS 6800 gas chromatograph–mass spectrometer is a cost-effective analytical system incorporating multiple patented technologies for routine and advanced laboratory applications. It is widely used in industrial inspection, food hygiene, environmental protection, and pharmaceutical analysis. The system integrates high-sensitivity mass detection, reliable gas chromatography, and a robust vacuum architecture to meet high-throughput analytical demands.
The GC-MS 6800 employs advanced electronic pressure control, a high-efficiency EI ionization source, and stable turbo molecular pumping to deliver reproducible results across complex matrices. It supports industrial users, research laboratories, and public security institutions requiring precise identification of organic compounds, contaminants, and trace residues.
The AELAB GC-MS 6800 combines a high-temperature GC oven, split/splitless injector, and electronically regulated EPC module with a quadrupole MS analyzer equipped with a high-energy dynode electron multiplier. The ion source operates from 100°C to 350°C, while the GC-MS interface supports temperatures up to 450°C to ensure efficient analyte transfer. A turbo molecular pump (67 L/s) stabilizes vacuum conditions to maintain detector sensitivity and mass stability (±0.10 amu/48 hrs).
The system performs chromatographic separation under EPC-regulated pressure conditions before compounds enter the EI ion source for electron-impact ionization (5 W–250 eV adjustable). Generated ions are filtered by a quadrupole mass analyzer providing unit resolution across 1.5–1000 amu. Full-scan and SIM acquisition modes enable identification, quantification, and structural interpretation of volatile and semi-volatile compounds. Data are collected through high-speed acquisition electronics for accurate peak integration and mass spectral analysis.
The ChemAnalyst software platform controls the auto sampler (AS), gas chromatograph (GC), and mass spectrometer (MS) with high-speed network card data communication. The system provides selective ion monitoring (SIM), full-scan acquisition, real-time vacuum monitoring, digital RF compensation, NIST spectral search capability, and automatic/ manual tuning options.
| Model | Specifications |
|---|---|
| GC-MS 6800 | 450°C inlet, 0^100 psi EPC control, 120°C/min heating, EI 5–250 eV, 1.5–1000 amu range, 1000 amu/s scan rate, turbo pump 67 L/s |
The AELAB GC-MS 6800 is suitable for brominated flame-retardants (BFR), volatile organic compounds (VOCs), polycyclic aromatic hydrocarbons (PAHs), phthalates, pesticide residues, flavors, fragrances, pharmaceutical compounds, petrochemical contaminants, explosive residues, and forensic evidence analysis.
The GC-MS 6800 complies with international analytical standards and supports NIST spectral libraries (current NIST 2011). The system is designed under ISO-aligned quality protocols and supports regulatory testing workflows related to REACH and RoHS requirements. All components undergo strict quality inspection to ensure measurement accuracy, stability, and reproducibility.
Specifications :
| GC Specifications | |
|---|---|
| Inlet temperature | Max. 450°C |
| Pressure range | 0^100 psi, ±0.002 psi |
| Pressure control mode | Electronic pressure control (EPC), support CV and CC |
| Split mode | Split/splitless, max. split ratio: 1000:1 |
| Column oven working temperature | Room temperature +4°C ~ 450°C |
| Heating rate | Up to 120°C/min |
| Temperature programming | 7 stages / 8 platforms |
| Auto Sampler | Optional |
| MS Specifications | |
| EI source ionization energy | 5 W ~ 250 eV (Adjustable) |
| Mass range | 1.5 ~ 1000 amu |
| Resolution | Unit resolution (full width at half maximum) |
| Ion source temperature | 100 ~ 350°C |
| Filament emission current | 0 ~ 350 μA |
| GC-MS Interface temperature | Max. 450°C |
| Stability | ±0.10 amu / 48 hrs |
| Sensitivity | Full scan, 1 pg OFN at m/z 272 with S/N ≥30:1 (RMS) |
| Scan rate | Up to 1000 amu/s |
| Vacuum | Turbo molecular pump (67 L/s) |
| Detector | High energy dynode electron multiplier |
| GC Specifications | |
|---|---|
| Inlet temperature | Max. 450°C |
| Pressure range | 0^100 psi, ±0.002 psi |
| Pressure control mode | Electronic pressure control (EPC), support CV and CC |
| Split mode | Split/splitless, max. split ratio: 1000:1 |
| Column oven working temperature | Room temperature +4°C ~ 450°C |
| Heating rate | Up to 120°C/min |
| Temperature programming | 7 stages / 8 platforms |
| Auto Sampler | Optional |
| MS Specifications | |
| EI source ionization energy | 5 W ~ 250 eV (Adjustable) |
| Mass range | 1.5 ~ 1000 amu |
| Resolution | Unit resolution (full width at half maximum) |
| Ion source temperature | 100 ~ 350°C |
| Filament emission current | 0 ~ 350 μA |
| GC-MS Interface temperature | Max. 450°C |
| Stability | ±0.10 amu / 48 hrs |
| Sensitivity | Full scan, 1 pg OFN at m/z 272 with S/N ≥30:1 (RMS) |
| Scan rate | Up to 1000 amu/s |
| Vacuum | Turbo molecular pump (67 L/s) |
| Detector | High energy dynode electron multiplier |