AELAB AE-RH Series Low Temperature Incubator for Precise Cooling and Stability

The AELAB AE-RH Series low temperature incubator provides precise cooling performance for laboratory, research, and industrial workflows requiring stable temperature control. With intelligent refrigeration management, uniform air circulation, and a refined Stainless Steel inner chamber, each model ensures accurate, reproducible, and reliable incubation across a wide operating range. Ideal for microbiology, BOD testing, material conditioning, and controlled environmental experiments.
Modles : AE-RH Series
whatsapp Whatsapp

The AELAB AE-RH Series low temperature incubator is designed with a double door structure and a large wide-angle glass door for clear chamber observation without dead angles. The patented double greenhouse temperature control system enhances temperature uniformity in the working space. A refrigerating capacity intelligent control system automatically regulates compressor power, providing rapid cooling and extended compressor lifespan.

The mirror Stainless Steel inner chamber features four semi-arc corners for easy cleaning, and the shelf spacing can be adjusted. The international brand compressor ensures efficient cooling performance and long-term reliability. A JAKEL tube-flow circulating fan provides stable air convection, enhancing uniform temperature distribution throughout the chamber.

 

⚙️ Design & Construction

The AELAB AE-RH Series incorporates a robust Stainless Steel inner liner, reinforced outer frame, and a transparent wide-angle observation door. The system integrates an LCD interface with multi-group data display, offering intuitive menu operation. Adjustable shelves, durable casters, and laboratory-grade insulation ensure reliable structural performance for continuous incubation cycles.

 

🔬 Working Principle / Testing Method

The incubator operates using an intelligent refrigeration cycle with automated compressor adjustment to maintain the programmed temperature range. Integrated PID temperature control ensures minimal fluctuation, while a precise 0.1 °C resolution supports accurate monitoring. Air is circulated uniformly via a tube-flow fan, creating stable convection for controlled low-temperature incubation, microbial growth inhibition studies, BOD testing, and material conditioning.

 

💡 Key Advantages

  • High precision temperature stability with dual-level ±0.5 °C / ±1 °C control
  • Uniform temperature distribution of ±1.0 °C under no-load conditions
  • Independent temperature limit alarm for laboratory safety
  • Optional RS485 interface and software for experiment data export
  • Energy-efficient R134a refrigerant supporting environmental compliance
  • Rapid cooling with intelligent compressor reflux management
  • Long service life with international-brand refrigeration components

 

🔗 Connectivity & Integration

The AE-RH Series supports RS485 communication for computer connection and data export. Optional embedded printers allow direct record output. External test hole ports (25 mm / 50 mm) enable insertion of external sensors or probes for real-time measurement verification.

 

🧠 Model Insight

Model Key Specifications
AE-RH150CL 150 L volume, -10~60 °C range, 1200 W, 480×400×780 mm (inner)
AE-RH250CL 250 L volume, -10~60 °C range, 1400 W, 580×500×850 mm (inner)
AE-RH500CL 500 L volume, -10~60 °C range, 2350 W, 700×700×1020 mm (inner)
AE-RH150CA 150 L volume, -20~60 °C range, 1200 W, 480×390×780 mm (inner)
AE-RH250CA 250 L volume, -20~60 °C range, 1400 W, 580×500×850 mm (inner)
AE-RH500CA 500 L volume, -20~60 °C range, 2350 W, 700×700×1020 mm (inner)

 

🧪 Testing Applications

The AELAB AE-RH Series is suitable for microbial incubation at low temperatures, BOD testing, seed storage, biochemical sample conditioning, material stress testing, pharmaceutical stability studies, and controlled environmental research across academic, industrial, and quality assurance laboratories.

 

Compliance & Quality Assurance

All AELAB AE-RH Series incubators are manufactured under strict ISO and GLP-aligned quality management systems. Components are performance-tested under 20 °C ambient temperature and 50% RH to ensure accuracy, reproducibility, and long-term operational stability.

Specifications :

 

Model AE-RH150CL AE-RH250CL AE-RH500CL AE-RH150CA AE-RH250CA AE-RH500CA
Power Requirement AC220V 50HZ
Temperature Range -10~60℃ -20~60℃
Temperature stability High ±0.5℃    lower:±1℃
Temperature Uniform ±1.0℃(no-load)
Display Resolution 0.1℃
Power 1200W 1400W 2350W 1200W 1400W 2350W
Inner dimension W×D×H(mm) 480×400×780 580×500×850 700×700×1020 480×390×780 580×500×850 700×700×1020
Outer dimension W×D×H(mm) 610×685×1370 710×785×1555 830×940×1795 605×740×1340 705×785×1490 825×1050×1790
Volume 150L 250L 500L 150L 250L 500L
Shelves (standard) 2pcs 2pcs 3pcs 2pcs 2pcs 3pcs
Timing 1~9999min

 

Model AE-RH150CL AE-RH250CL AE-RH500CL AE-RH150CA AE-RH250CA AE-RH500CA
Power Requirement AC220V 50HZ
Temperature Range -10~60℃ -20~60℃
Temperature stability High ±0.5℃    lower:±1℃
Temperature Uniform ±1.0℃(no-load)
Display Resolution 0.1℃
Power 1200W 1400W 2350W 1200W 1400W 2350W
Inner dimension W×D×H(mm) 480×400×780 580×500×850 700×700×1020 480×390×780 580×500×850 700×700×1020
Outer dimension W×D×H(mm) 610×685×1370 710×785×1555 830×940×1795 605×740×1340 705×785×1490 825×1050×1790
Volume 150L 250L 500L 150L 250L 500L
Shelves (standard) 2pcs 2pcs 3pcs 2pcs 2pcs 3pcs
Timing 1~9999min

Frequently Asked Questions

1What applications is the AELAB AE-RH Series suitable for?
It is used for low-temperature incubation, BOD analysis, microbial culture at reduced temperatures, pharmaceutical conditioning, and material stability testing.
2What is the temperature uniformity of the AE-RH Series?
The incubator maintains ±1.0 °C uniformity under no-load conditions.
3Does the incubator support data export?
Yes, via optional RS485 interface and software, with an embedded printer option for direct output.
4What safety features are included?
An independent temperature limit alarm forcibly stops heating when limits are exceeded.
5What is the operating temperature range?
CL models operate at -10~60 °C, while CA models support -20~60 °C.