AELAB HY-100 Series Vibration Density Tester for Powder Tap Density Measurement

The AELAB HY-100 Series vibration density tester measures powder tap density under controlled vibration frequency and amplitude. Using adjustable-speed vibration components, precision volumetric cylinders, and microcomputer-based control, the instrument ensures uniform compaction and accurate density results for research, pharmaceutical, and material testing applications.
Modles : HY-100A~HY-100B~HY-100C
whatsapp Whatsapp

The AELAB HY-100 Series vibration density tester is designed for measuring the density of powders by determining the mass per unit volume after controlled vibration. The instrument regulates vibration amplitude, frequency, and duration to ensure uniform compaction and accurate density determination under specified test conditions.

The HY-100 Series complies with GB/T 5162-2006/ISO3953:1993 standards for tap density of metal powders and references the United States Pharmacopoeia. It integrates adjustable-speed vibration components, microcomputer control, and automated calculation and printing of test results.

 

⚙️ Design & Construction

The AELAB HY-100 Series uses an adjustable-speed motor, precision vibration assembly, calibrated volumetric cylinders (25ml, 50ml, 100ml, and 250ml depending on model), and Stainless Steel Φ12mm vibration damping pads. The organosilicon gasket set ensures airtight, stable measurement. The microcomputer system manages vibration cycles, torque, amplitude, and uniformity control.

 

🔬 Working Principle / Testing Method

The instrument measures tap density by applying controlled vertical vibration to a volumetric cylinder containing powder. Adjustable amplitude from 1–15mm and a 0–300rpm frequency range provide reproducible compaction. Once the vibration count is complete, the microcomputer calculates tap density or bulk density (when the cycle count is set to 0). Results follow standardized methods for powder density quantification.

 

💡 Key Advantages

  • Continuously adjustable vibration frequency up to 300rpm
  • Integer-controlled vibration amplitude from 1–15mm for precise compaction
  • 0–99999 vibration cycle range with automatic bulk density mode
  • High repeatability and accuracy error ≤1%
  • Stainless Steel damping components for long-term durability
  • Multiple volumetric cylinder capacities for different powder types
  • Microcomputer calculation for traceable and standardized results

 

🔗 Connectivity & Integration

The HY-100 Series includes microcomputer-based data control with direct result calculation and print output. It supports GLP workflows requiring standardized tap density reporting. Power interface: AC 220V, 50/60Hz.

 

🧠 Model Insight

Model Specifications
HY-100 A 25ml/50ml/100ml/250ml cylinders, ≤500g specimen weight, 0–99999 vibrations
HY-100 B 25ml/50ml/100ml cylinders, ≤500g specimen weight, dual vibration assemblies
HY-100 C 25ml/50ml/100ml cylinders, triple vibration assemblies, ≤100ml capacity

 

🧪 Testing Applications

The AELAB HY-100 Series is used for powder density measurement in metallurgy, pharmaceuticals, ceramics, chemical powders, additive manufacturing feedstocks, and material science research. It quantifies tap density, bulk density, and compaction characteristics under controlled vibration conditions.

 

Compliance & Quality Assurance

The HY-100 Series conforms to GB/T 5162-2006, ISO3953:1993, and USP reference methods. All units undergo AELAB quality inspection, calibrated torque verification, and GLP-compatible performance validation.

Specifications :

Instrument Configuration

Model HY-100 A HY-100 B HY-100 C
Densitometer vitality HY-100 HY-100 B HY-100 C
Vibration components HY-100 HY-100 B HY-100 C
Gaskets Organosilicon Organosilicon Organosilicon
Volumetric cylinder 25ml/50ml/100ml/250ml 25ml/50ml/100ml 25ml/50ml/100ml
Vibration damping (Stainless steel Φ12mm) 1mm/2mm/5mm 1mm/2mm/5mm 1mm/2mm/5mm
Power line 250V 10A 250V 10A 250V 10A
Fuse wire 5*20mm,1A 5*20mm,1A 5*20mm,1A
Test tube brush / / /
Silicone mat Φ70mm*2mm Φ70mm*2mm Φ70mm*2mm

 

Technical Specification

 

Model HY-100 A HY-100 B HY-100 C
Specimen weight 500.00g
Specimen volume ≤250.00ml ≤100.00ml ≤100.00ml
Number of single vibrations 0–99999 times (When set to 0 times the result is output as ‘Bulk density.’)
Allowable motor torque 0.86 N.m
Vibration frequency 0–300rpm (continuously adjustable)
Amplitude of vibration Maximum 15mm, Integer 1–15mm adjustable
Repeatability error ≤1%
Accuracy error ≤1%
Input Power AC 220V (50Hz/60Hz), 40W

Instrument Configuration

Model HY-100 A HY-100 B HY-100 C
Densitometer vitality HY-100 HY-100 B HY-100 C
Vibration components HY-100 HY-100 B HY-100 C
Gaskets Organosilicon Organosilicon Organosilicon
Volumetric cylinder 25ml/50ml/100ml/250ml 25ml/50ml/100ml 25ml/50ml/100ml
Vibration damping (Stainless steel Φ12mm) 1mm/2mm/5mm 1mm/2mm/5mm 1mm/2mm/5mm
Power line 250V 10A 250V 10A 250V 10A
Fuse wire 5*20mm,1A 5*20mm,1A 5*20mm,1A
Test tube brush / / /
Silicone mat Φ70mm*2mm Φ70mm*2mm Φ70mm*2mm

 

Technical Specification

 

Model HY-100 A HY-100 B HY-100 C
Specimen weight 500.00g
Specimen volume ≤250.00ml ≤100.00ml ≤100.00ml
Number of single vibrations 0–99999 times (When set to 0 times the result is output as ‘Bulk density.’)
Allowable motor torque 0.86 N.m
Vibration frequency 0–300rpm (continuously adjustable)
Amplitude of vibration Maximum 15mm, Integer 1–15mm adjustable
Repeatability error ≤1%
Accuracy error ≤1%
Input Power AC 220V (50Hz/60Hz), 40W

Product Video:

Frequently Asked Questions

1What type of powders can the HY-100 Series measure?
It analyzes metal powders, pharmaceutical powders, chemical powders, and fine particulate materials requiring standardized tap density testing.
2Can the vibration amplitude be adjusted?
Yes, amplitude is adjustable from 1–15mm in integer steps.
3What is the maximum vibration frequency?
The system provides 0–300rpm continuous adjustment.
4Does the instrument measure bulk density?
Yes, setting vibration cycles to “0” outputs bulk density automatically.
5What power requirements does the instrument use?
All HY-100 models operate at AC 220V (50Hz/60Hz), 40W.