Feyond-A300 multi-mode microplate reader is specially designed for medical, biological and pharmaceutical research and development institutions to meet the needs of various drug development and life science research. The high-quality detection performance ensures high-quality analysis based on molecular biology, biochemistry and cytology.
In addition to the full-wavelength absorbance, fluorescence and luminescence detection functions, it is also compatible with the client modular upgrade function. Users can upgrade to the ultra-micro plate and flash detection with automatic injector as needed.
The absorbance of Feyond-A300 is based on monochromator, which can realize continuous spectrum detection of 200 – 1000nm without a filter, which meets almost all absorbance detection applications. Fluorescence detection adopts the detection light path of the filter. The fluorescence path composed of Xenon lamp, filter and PMT can fit the characteristics of fluorescent dye to the greatest extent, ensuring excellent detection performance and high-quality detection effect. Luminescence detection also uses PMT as the detector, and the sensitivity can reach a dynamic range of more than 6 orders of magnitude. The detachable modular fluorescence detection filter can identify the filter information only by scanning the code. The modular design provides the convenience of filter replacement, which is more convenient for experiments and shortens the operation time.
The instrument is equipped with a 10 inch touch screen. According to the researcher’s operation habit of the instrument, the screen angle can be converted through the LCD control button to facilitate the researcher’s setting of the instrument. The instrument is no need to connect a computer. The layout, operating parameters, and algorithm and the other settings can be completed by a single machine. The built-in software of the instrument includes multiple algorithm analysis functions of standard curve, qualitative and quantitative, basic calculation, kinetics, spectroscopy and etc, which makes more convenient for the processing and research of experimental data.
Feyond-A300 adopts PID temperature control technology. When the experimental plate is covered or closed, the edge effect can be reduced through the differential temperature between the top and bottom of the plate, so as to ensure the data stability of the sample in the process of dynamic analysis.
In addition, the Feyond-A300 has a code scanning function, which can not only identify the filters informations, but also create a QR code for the experimental program or standard curve. Researcher can quickly import the experimental program into the instrument through the QR code.
Features:
Multi-mode detection: Absorbance (200–1000 nm), Fluorescence, and Luminescence in one system.
Fast & accurate: 96-well plate reading in ~15s, ppb-level sensitivity, wide dynamic range.
Modular upgradeability: Options for injectors, incubator, fluorescence top reading, luminescence modes, and u-Nano plate testing.
Advanced optics: Monochromator-based absorbance, filter-based fluorescence, and PMT-enhanced luminescence.
User-friendly interface: 10-inch adjustable touchscreen with built-in analysis software, no PC required.
Data management: Stores up to 20 million results and 500 projects, supports multiple report formats.
Temperature control: PID system reduces edge effects for stable kinetic and dynamic assays.
Future-ready: Upgradeable to Feyond-A400 with time-resolved fluorescence (TRF) for advanced biomedical applications.
Specifications :
| Basic Information | Detection limit | 100 amol/well | |
| Tyрe | Feyond-A300/A400 | Linear dynamic range | 6 logs |
| Function | Absorbance,fluorescence,luminescence,TRF | Crosstalk | <0.005% |
| Plate Formats | 96&384 wells (6/12/24/48 optional) | Shaking& Incubation | |
| Absorbance | Shaking mode | Linear, circular, double circular | |
| Light source | Xenon lamp | Incubation temperature | RT +4°C to 45°C |
| Detector | PD | Temperature uniformity | ±0.5°C @ 37°C |
| Wavelength accuracy | 200-1000nm,1nm step | Operation method | Touch capacitive screen; use mouse |
| Measure range | 0-4 OD | Data capacity | 10 GB |
| Resolution | 0.0001 OD | Compatibility | Support PC software, win7 to win10 64 bit |
| Accuracy | 96-precision mode士(1.0%+0.003Abs) @(0.0-2.0Abs]士2.0% @ (2.0-3.0Abs] | Data transmission | Test data report can be uploaded to PCserver via FTP |
| Others | |||
| Repeatability | CV<1.0% or SD<0.003 fast (0.0-3.0Abs]CV<0.5% or SD<0.003 accurate (0.0-3.0Abs] | instrument port | 2 USB A type ports / 1 usB B type port1 Ethernet port Rs232 bus interface(sampling device connection) |
| Stray light | 0.1% @ 220 nm | ||
| Linear | R2>0.999 @ [0.0-3.0Abs] | Size (WxDxH)mm | 420x550x386 |
| Reading time | 96-well plate: fast <15s | Power supply | AC 100 to 240V, 50 to 60Hz |
| Fluorescence | Weight | 33kg | |
| Reading mode | Top reading | u-Nano Ultra-Micro Plate (Optional) | |
| Excitation light
source |
Xenon lamp | Number of samples | 1-16 |
| Detector | PMT | Sample detection volume | 2-4uL |
| Wavelength range | EX:200-1000nm;EM: 270-850nm | Automatic Injector Module (Optional) | |
| Filter EX/EM | 3 groups: EX470/EM525,EX523/EM564,EX624/EM692 (Other wavelengths can be freely replaced | Quantity | 1,2 |
| Detection limit | ≤1pM | Dispensing volume | 5-1000μL,1 μL increment |
| Linear dynamic range | 6 logs | Liquid injection speed | 125-500μL/s |
| Time-resolved Fluorescence (TRF)(Feyond-A400) | Accuracy | ±1μL @ 5-50μL
士2% @ 51-1000μL |
|
| Detection limit | Europium <0.25pM | Waste liquid collection | 50mL |
| Luminescence | PC Software (Optional) | ||
| Detector | PMT | Analysis Software | Readerlt-ll software |
| Basic Information | Detection limit | 100 amol/well | |
| Tyрe | Feyond-A300/A400 | Linear dynamic range | 6 logs |
| Function | Absorbance,fluorescence,luminescence,TRF | Crosstalk | <0.005% |
| Plate Formats | 96&384 wells (6/12/24/48 optional) | Shaking& Incubation | |
| Absorbance | Shaking mode | Linear, circular, double circular | |
| Light source | Xenon lamp | Incubation temperature | RT +4°C to 45°C |
| Detector | PD | Temperature uniformity | ±0.5°C @ 37°C |
| Wavelength accuracy | 200-1000nm,1nm step | Operation method | Touch capacitive screen; use mouse |
| Measure range | 0-4 OD | Data capacity | 10 GB |
| Resolution | 0.0001 OD | Compatibility | Support PC software, win7 to win10 64 bit |
| Accuracy | 96-precision mode士(1.0%+0.003Abs) @(0.0-2.0Abs]士2.0% @ (2.0-3.0Abs] | Data transmission | Test data report can be uploaded to PCserver via FTP |
| Others | |||
| Repeatability | CV<1.0% or SD<0.003 fast (0.0-3.0Abs]CV<0.5% or SD<0.003 accurate (0.0-3.0Abs] | instrument port | 2 USB A type ports / 1 usB B type port1 Ethernet port Rs232 bus interface(sampling device connection) |
| Stray light | 0.1% @ 220 nm | ||
| Linear | R2>0.999 @ [0.0-3.0Abs] | Size (WxDxH)mm | 420x550x386 |
| Reading time | 96-well plate: fast <15s | Power supply | AC 100 to 240V, 50 to 60Hz |
| Fluorescence | Weight | 33kg | |
| Reading mode | Top reading | u-Nano Ultra-Micro Plate (Optional) | |
| Excitation light
source |
Xenon lamp | Number of samples | 1-16 |
| Detector | PMT | Sample detection volume | 2-4uL |
| Wavelength range | EX:200-1000nm;EM: 270-850nm | Automatic Injector Module (Optional) | |
| Filter EX/EM | 3 groups: EX470/EM525,EX523/EM564,EX624/EM692 (Other wavelengths can be freely replaced | Quantity | 1,2 |
| Detection limit | ≤1pM | Dispensing volume | 5-1000μL,1 μL increment |
| Linear dynamic range | 6 logs | Liquid injection speed | 125-500μL/s |
| Time-resolved Fluorescence (TRF)(Feyond-A400) | Accuracy | ±1μL @ 5-50μL
士2% @ 51-1000μL |
|
| Detection limit | Europium <0.25pM | Waste liquid collection | 50mL |
| Luminescence | PC Software (Optional) | ||
| Detector | PMT | Analysis Software | Readerlt-ll software |
Download catalog for: