info@aelabgroup.com
QR Code 1
QR Code 2

AELAB Ion Chromatograph OLC-900 – High Sensitivity Ion Analysis

The AELAB Ion Chromatograph OLC-900 offers precise, high-sensitivity ion detection ideal for environmental, pharmaceutical, and industrial labs. Featuring patented suppressor technology and intelligent automation, it ensures reliable, efficient analysis with minimal maintenance.

Modles : 0lC-900
whatsapp Whatsapp
  • Environmental Protection.
  • Petrochemical
  • Drinking Water
  • Antiepidemic and food
  • Metallurgical Ore
  • Pharmacy
  • Chemical Industry
  • Pesticides
  • Semiconductor
  • Nuclear Power

 

Features:

  • High sensitivity
    Highly sensitive diode conductivity detector
  • Patented technology
    Suppressor constant current source device, can accurately adjust the current
  • Full peek flow path
    Full peek flow path, acid and alkali resistance, corrosion resistance.
  • Anion and cation one-button automatic switching device
    Anion and cation one-button automatic switching device realizes one-button intelligent switching between anion and cation systems, without manual disassembly and assembly of the flow path, which greatly saves experimental operation time and avoids the risk of frequent disassembly and assembly leakage, simple and efficient.
  • Intelligent switch
    One-button start, intelligent boot
    One-key automatic shutdown, automatically execute scientific shutdown process, improve work efficiency; Timing shutdown, cooperate with the eluent generator and auto sampler to realize 24-hour uninterrupted work.
  • Self-regenerating electromembrane suppressor
    Self-regenerative electromembrane suppessor, with low suppression background and high suppression capacity. can perectly replace imported suppressors.
  • Suppressor automatic protection system
    Avoid dry burning damage to the suppressor caused by misuse and other reasons, more secured use and longer life.
  • Switch repeatedly for over 100,000 times
    Imported high-pressure resistant six – way sampling valve,can be repeatedly switched for 100,000 times without leakage.
  • Precise temperature control devices
    Precise temperature control devices for columns and detectors make the column eficiency higher, the balance faster and the signal more stable.

 

🔬 How It Works? 🔬

The OLC-900 operates by separating ions in samples using advanced chromatographic techniques. Its patented electromembrane suppressor reduces background noise by continuously regenerating and chemically suppressing unwanted ions, improving sensitivity. Anion and cation detection systems switch automatically via a one-button intelligent device, eliminating manual flow path changes. The system uses precise temperature control for columns and detectors, ensuring stable signals and high column efficiency. Samples are injected through a high-pressure resistant valve maintaining flow continuity to avoid pressure shocks.

 

💡 Advantages 💡

  • High Sensitivity: Detects ions at ultra-low concentrations with minimal baseline noise.

  • Smart Automation: One-button intelligent switching and auto shutdown reduce human error and save time.

  • Durability: Corrosion-resistant flow paths and a suppressor protection system extend equipment life.

  • Efficient Workflow: Continuous self-regenerating suppressor and stable temperature control maximize uptime and data reliability.

  • User-Friendly Software: Bilingual reports and batch processing streamline data handling and analysis.

 

🔍 Recommended Models by Use Case 🔍

  • Educational Labs: Reliable, easy to operate with automated features, ideal for teaching ion chromatography basics.

  • Research Centers: High sensitivity and flexible operation suit complex sample analysis and method development.

  • Quality Control Departments: Automated suppression and injection offer repeatable results for routine testing.

  • Environmental & Food Testing Labs: Corrosion-resistant materials handle diverse sample matrices like water, pesticides, and food additives.

 

🧪 Ideal For 🧪

  • Environmental monitoring

  • Petrochemical analysis

  • Drinking water quality testing

  • Pharmaceutical research and production

  • Chemical and pesticide analysis

  • Semiconductor and nuclear power industry testing

  • Metallurgical ore composition

  • Antiepidemic and food safety labs

Specifications :

Equipment Name Parameters
Electromembrane suppressor Online-electrolytic water generation
Continuous self-regeneration
Small dead volume: <9μL
Low suppression background: <1.0μS/cm
Type of suppressor: anion and cation suppressor
Self-regeneration, chemical suppression type, ion suppression type
Suppression capacity: >100μeq/min
Embedded column oven (patented technology) Adopt imported A+ grade platinum resistance
Temperature control range: room temperature - 5℃ - 60℃
Temperature control accuracy: ±0.01℃
Six-way sampling valve Patented non-stop continuous flow (MBB) structure design
Maintains flow continuity when switching sampling and injection
Reduces interference of instantaneous pressure shock on the system
Wide 30 degree port, easy to connect with the connector
Single-point pressure adjustment reduces friction between rotor seal and stator
Prolongs service life
Built-in position sensing switch provides a reproducible start signal
Withstand voltage: 35MPa
Connecting piping: 1/16" (0.02")
Flow path diameter: 0.5mm
Screw specification: No.10 - 32UNF
Sample loop: 25μL
Injection labeling: Built-in Type
Conductivity detector Material: 316 stainless steel needle electrode
Cell Volume: <0.8μL
Temperature control range: room temperature + 5℃ - 60℃
Temperature control accuracy: ±0.01℃
Baseline noise: ≤0.2nF/S/30min
Baseline drift: ≤1nF/S/30min
Quantitative repeatability: ≤1.0%
Qualitative repeatability: ≤0.2%
Minimum detection concentration: Cl- < 0.0008μg/mL
Miniature high pressure intelligent constant flow pump Pump pressure: 42MPa (6000psi)
Flow range: 0.001 - 9.999mL/min
Repeatability of flow: RSD ≤ 0.01%
Maximum operating pressure: 5000psi
Flow accuracy: RSD < 0.1%
High-performance corrosion-resistant material sealing ring adapts to various eluent systems
Prevents leakage and prolongs life
Chromatographic workstation Unique spectral peak intelligent identification technology
Processes peak identification, baseline correction, and overlapping peak segmentation
Formulates analysis reports in Chinese and English with pictures and texts
Directly generates and prints in Word
Exports results to spreadsheets (e.g., Excel) for secondary calculations
Processes multiple spectra in batches at one time
Equipment Name Parameters
Electromembrane suppressor Online-electrolytic water generation
Continuous self-regeneration
Small dead volume: <9μL
Low suppression background: <1.0μS/cm
Type of suppressor: anion and cation suppressor
Self-regeneration, chemical suppression type, ion suppression type
Suppression capacity: >100μeq/min
Embedded column oven (patented technology) Adopt imported A+ grade platinum resistance
Temperature control range: room temperature - 5℃ - 60℃
Temperature control accuracy: ±0.01℃
Six-way sampling valve Patented non-stop continuous flow (MBB) structure design
Maintains flow continuity when switching sampling and injection
Reduces interference of instantaneous pressure shock on the system
Wide 30 degree port, easy to connect with the connector
Single-point pressure adjustment reduces friction between rotor seal and stator
Prolongs service life
Built-in position sensing switch provides a reproducible start signal
Withstand voltage: 35MPa
Connecting piping: 1/16" (0.02")
Flow path diameter: 0.5mm
Screw specification: No.10 - 32UNF
Sample loop: 25μL
Injection labeling: Built-in Type
Conductivity detector Material: 316 stainless steel needle electrode
Cell Volume: <0.8μL
Temperature control range: room temperature + 5℃ - 60℃
Temperature control accuracy: ±0.01℃
Baseline noise: ≤0.2nF/S/30min
Baseline drift: ≤1nF/S/30min
Quantitative repeatability: ≤1.0%
Qualitative repeatability: ≤0.2%
Minimum detection concentration: Cl- < 0.0008μg/mL
Miniature high pressure intelligent constant flow pump Pump pressure: 42MPa (6000psi)
Flow range: 0.001 - 9.999mL/min
Repeatability of flow: RSD ≤ 0.01%
Maximum operating pressure: 5000psi
Flow accuracy: RSD < 0.1%
High-performance corrosion-resistant material sealing ring adapts to various eluent systems
Prevents leakage and prolongs life
Chromatographic workstation Unique spectral peak intelligent identification technology
Processes peak identification, baseline correction, and overlapping peak segmentation
Formulates analysis reports in Chinese and English with pictures and texts
Directly generates and prints in Word
Exports results to spreadsheets (e.g., Excel) for secondary calculations
Processes multiple spectra in batches at one time

Frequently Asked Questions

1How is calibration done?
Calibration is performed using standard solutions with the chromatographic workstation’s intelligent peak identification to ensure accurate quantification.
2Is the device GMP compliant?
Yes, the OLC-900 meets GMP standards required for pharmaceutical and food laboratories.
3How long is the warranty?
The instrument comes with a standard 12-month warranty covering parts and labor.
4How does the suppressor protect itself?
The automatic protection system prevents dry burning damage, enhancing safety and prolonging suppressor life.
5Can the system operate continuously?
Yes, the OLC-900 supports 24-hour uninterrupted operation with auto-shutdown and timing functions.

Request Quote: AELAB Ion Chromatograph OLC-900 – High Sensitivity Ion Analysis