AELAB DP29 Chilled Mirror Dew Point Instrument for Portable Dew Point Humidity Measurement

The AELAB DP29 Chilled Mirror Dew Point Instrument is a multifunctional portable dew point humidity meter designed for field and laboratory dew point measurement. Based on the chilled mirror measurement principle, the DP29 series quantifies dew point temperature with stable performance and no need for repeated calibration. Integrated electronic sample gas flow monitoring and RS-232 data output enable accurate dew point analysis and PC connectivity for quality control applications.
Modles : DP29-40 , DP29-60 , DP29-SF6
whatsapp Whatsapp

The AELAB DP29 Chilled Mirror Dew Point Instrument is a multifunctional portable dew point humidity meter specifically designed for accurate field dew point measurement and laboratory reference applications. The DP29 series applies the chilled mirror measurement principle to quantify dew point temperature with high stability, enabling consistent chilled mirror dew point analysis without the need to repeatedly calibrate.

The AELAB DP29 Chilled Mirror Dew Point Instrument is typically used for dew point measurement of SF6 gas and for controlled moisture management processes. Integrated electronic sample gas flow monitoring and RS-232 data output support reliable chilled mirror dew point measurement workflows and PC-based data management in industrial quality control, environmental testing, and diagnostic laboratory analysis.

 

⚙️ Design & Construction

The AELAB DP29 Chilled Mirror Dew Point Instrument integrates semiconductor refrigeration for controlled mirror cooling and stabilized dew point condensation detection. The DP29 series is engineered as a compact portable chassis with a dedicated measurement probe interface and built-in electronic sample gas flow monitoring for stable dew point humidity measurement. The AELAB DP29 includes instrument self-check functions for mirror check and cooling performance verification to support long-term measurement integrity.

 

🔬 Working Principle / Testing Method

The AELAB DP29 Chilled Mirror Dew Point Instrument performs chilled mirror dew point measurement by cooling a mirror surface until condensation forms at the dew point temperature. The instrument regulates mirror temperature using semiconductor refrigeration and detects the condensation equilibrium condition to measure dew point precisely. The AELAB DP29 stabilizes measurement using controlled inlet flow and inlet pressure conditions, then outputs dew point data through USB (default) or optional analog outputs for process integration.

 

💡 Key Advantages

  • The AELAB DP29 Chilled Mirror Dew Point Instrument uses the chilled mirror measurement principle for accurate dew point humidity measurement
  • Measurement Accuracy ≤ ±0.2°C supports precise dew point temperature quantification for laboratory and industrial testing
  • Repeatability ≤ ±0.1°C ensures stable chilled mirror dew point measurement under controlled flow and pressure conditions
  • Resolution 0.1°C provides fine dew point humidity measurement granularity for trace moisture control
  • Response Time 2°C/Second (Maximum) supports rapid dew point measurement in field monitoring and process environments
  • Integrated electronic sample gas flow monitor improves measurement stability during dew point humidity measurement sampling
  • No need to repeatedly calibrate due to stable chilled mirror measurement principle and internal check functions

 

🔗 Connectivity & Integration

  • Default Output: USB for PC connection and digital data acquisition.
  • Optional Output: ±10 mV/°C (0°C = 0 mV) or 4 mA–20 mA for industrial signal conversion and control systems.
  • Optional Accessories: RS-232C Data Cable with Software for extended PC-based data management and integration.

 

🧠 Model Insight

The AELAB DP29 series includes three chilled mirror dew point instrument variants optimized for air dew point measurement, laboratory calibration reference, and SF6 gas dew point measurement.

Model Insight – AELAB DP29 Chilled Mirror Dew Point Instrument Variants
Model Primary Target Dew Point Measurement Range (Under 0°C) Dimensions (W × H × D) Weight
DP29-40 Air dew point measurement and industrial dew point control -40°C 342 mm × 140 mm × 326 mm About 7.22 kg
DP29-60 Laboratory calibration reference and moisture control systems -50°C 342 mm × 140 mm × 326 mm About 7.22 kg
DP29-SF6 SF6 gas dew point measurement instrument for Sulfur Hexafluoride -50°C 342 mm × 140 mm × 326 mm About 7.22 kg

 

🧪 Testing Applications

The AELAB DP29 Chilled Mirror Dew Point Instrument is designed for dew point humidity measurement in field and laboratory environments, supporting moisture quantification and dew point control across industrial and scientific workflows.

  • SF6 Gas Testing: The AELAB DP29-SF6 performs dew point measurement of Sulfur Hexafluoride (SF6) gas in high-voltage and insulation gas management workflows.
  • Laboratory Calibration: The AELAB DP29-60 applies as a standard reference for laboratory dew point calibration and controlled moisture verification.
  • Industrial Process Control: The AELAB DP29-40 supports dew point control for firing furnaces, electronic component durability testing, and fuel cell test system moisture management.
  • Environmental & Quality Control: The AELAB DP29 quantifies dew point humidity measurement conditions to support reliable sampling, monitoring, and diagnostic validation.
  • Climate & Chamber Testing: The AELAB DP29-60 supports humidity control workflows for thermo-hygrostat chamber validation and moisture stability testing.

 

Compliance & Quality Assurance

The AELAB DP29 Chilled Mirror Dew Point Instrument is engineered for stable chilled mirror dew point measurement with built-in mirror check and instrument check functions to support measurement confidence. The AELAB DP29 supports controlled inlet flow (15 L/h–60 L/h) and inlet pressure (10 mbar–10 bar) sampling stability for reproducible dew point humidity measurement. Digital USB output and optional RS-232C connectivity support traceable data capture aligned with laboratory quality control and documented testing procedures.

For high-accuracy moisture quantification in industrial and laboratory environments, the AELAB DP29 Chilled Mirror Dew Point Instrument delivers stable chilled mirror dew point measurement performance with precise accuracy, repeatability, and connectivity for PC-based data management.

Specifications :

Technical Specifications – AELAB DP29 Series Chilled Mirror Dew Point Instrument
Model DP29-40 DP29-60 DP29-SF6
Range – Under 0 °C -40 °C -50 °C -50 °C
Range – Under 10 °C -40 °C -50 °C -50 °C
Range – Under 20 °C -35 °C -45 °C -45 °C
Range – Under 35 °C -30 °C -40 °C -40 °C
Accuracy ≤ ±0.2 °C + 1 digit
Repeatability ≤ ±0.1 °C + 1 digit
Resolution 0.1 °C
Default Output USB
Optional Output ±10mV/°C (0 °C = 0mV) or 4mA–20mA
Measurement Principle Chilled Mirror
Refrigeration Semiconductor Refrigeration
Inlet Flow 15L/h~60L/h, generally 30L/h~40L/h
Inlet Pressure 10mbar–10bar (1kPa–1MPa)
Response Time 2 °C/second (Maximum)
Voltage 220VAC ±10%, 50Hz/60 Hz
Pump Optional Accessory
Consumption About 160 W
Operating Temperature 0 °C–50 °C
Operating Humidity < 90%, No Condensation
Dimension 342(W) mm × 140(H) mm × 326(D) mm
Weight About 7.22 kg
Standard Main Unit
Accessories Inlet Tube (FEP, 3 m), With Connector
Included Documents Instruction Manual, Packaging Box
Optional Accessories RS-232C Data Cable with Software
Mirror Check Press the Mode Conversion Key to mirror check mode (“CH” on the display), and check manually.
Instrument Check Press the Test Cooling Key, open the measurement probe, and check manually at mirror check mode.
Technical Specifications – AELAB DP29 Series Chilled Mirror Dew Point Instrument
Model DP29-40 DP29-60 DP29-SF6
Range – Under 0 °C -40 °C -50 °C -50 °C
Range – Under 10 °C -40 °C -50 °C -50 °C
Range – Under 20 °C -35 °C -45 °C -45 °C
Range – Under 35 °C -30 °C -40 °C -40 °C
Accuracy ≤ ±0.2 °C + 1 digit
Repeatability ≤ ±0.1 °C + 1 digit
Resolution 0.1 °C
Default Output USB
Optional Output ±10mV/°C (0 °C = 0mV) or 4mA–20mA
Measurement Principle Chilled Mirror
Refrigeration Semiconductor Refrigeration
Inlet Flow 15L/h~60L/h, generally 30L/h~40L/h
Inlet Pressure 10mbar–10bar (1kPa–1MPa)
Response Time 2 °C/second (Maximum)
Voltage 220VAC ±10%, 50Hz/60 Hz
Pump Optional Accessory
Consumption About 160 W
Operating Temperature 0 °C–50 °C
Operating Humidity < 90%, No Condensation
Dimension 342(W) mm × 140(H) mm × 326(D) mm
Weight About 7.22 kg
Standard Main Unit
Accessories Inlet Tube (FEP, 3 m), With Connector
Included Documents Instruction Manual, Packaging Box
Optional Accessories RS-232C Data Cable with Software
Mirror Check Press the Mode Conversion Key to mirror check mode (“CH” on the display), and check manually.
Instrument Check Press the Test Cooling Key, open the measurement probe, and check manually at mirror check mode.

No download files available for this product.

Frequently Asked Questions

1What is the AELAB DP29-40 used for?
The AELAB DP29-40 chilled mirror dew point instrument is used for dew point humidity measurement in field and laboratory testing, including moisture control verification and analytical dew point monitoring.
2What is the dew point measurement range of the AELAB DP29-40?
The AELAB DP29-40 measures dew point down to -40 °C, with extended conditional ranges depending on operating conditions.
3How accurate is the AELAB DP29-40 chilled mirror dew point instrument?
The AELAB DP29-40 specifies accuracy of ≤ ±0.2 °C + 1 digit, with repeatability ≤ ±0.1 °C + 1 digit.
4Does the AELAB DP29-40 support data export and PC connectivity?
Yes. The AELAB DP29-40 provides USB default output and supports RS-232 communication for PC connection. Optional analog outputs include ±10 mV/°C or 4 mA–20 mA.
5What are the operating conditions for the AELAB DP29-40?
Operating temperature is 0 °C–50 °C, with operating humidity < 90%, non-condensing.