The Melting Point Devices HMPD Series offers a comprehensive range of precision equipment for determining the melting points of various substances. The AE-HMPD100, AE-HMPD200, and AE-HMPD300 models are designed with advanced features and various options to meet the diverse needs of laboratories. The AE-HMPD100, the entry-level model, offers reliable performance with a temperature range from ambient to 300°C and a display resolution of 0.1°C. It can accommodate up to three samples at once and offers both fast and slow ramp rates for precise control of the heating process. The AE-HMPD200 builds upon this foundation with enhanced functionality, allowing for faster temperature ramping at 20°C/min, a more efficient light path for clearer viewing, and improved control of the fast stage temperature to reduce measurement time. The AE-HMPD300 takes this a step further with an internal cooling fan that enables a cooling rate of 25°C/min, double displays for both inside and outside views, and a hand-held “READ” push button for quicker data recording. Additionally, the AE-HMPD300 offers data storage for permanent recording and is fully capable of calibration, either chemically or with an external probe. Whether you’re working with smaller quantities or need to ensure quick cooling between tests, the HMPD Series offers a versatile, cost-effective solution for precise melting point analysis.
Temperature Range: Ambient to 300°C
Temperature Accuracy: ± 0.5°C
Display: Four-digit LED display
Display Resolution: 0.1°C
Number of Samples: Up to 3 samples simultaneously
Fast Ramp Rate: Fixed at 20°C/min
Slow Ramp Rate: Adjustable from 0.2°C/min to 10°C/min (in 0.1°C/min increments)
Calibration: Supports chemical calibration or external probe calibration
Design: Compact, suitable for basic laboratory needs
Temperature Range: Ambient to 350°C
Temperature Accuracy: ± 0.5°C
Display: Four-digit LED display
Display Resolution: 0.1°C
Number of Samples: Up to 3 samples simultaneously
Fast Ramp Rate: Fixed at 20°C/min
Slow Ramp Rate: Adjustable from 0.2°C/min to 10°C/min (in 0.1°C/min increments)
Improved Light Path: Brighter and clearer view with no scattering or fuzzy vision
Fast Stage Temperature Control: Once fast stage temperature is reached, it is held without overshooting
Audible Reminder: A beep sounds when the fast stage temperature is reached, reminding users to proceed with the next step
“Read” Button: Simultaneously holds the melting point reading and heating process, allowing easy differentiation between two samples
Calibration: Supports chemical calibration or external probe calibration
Temperature Range: Ambient to 400°C
Temperature Accuracy: ± 0.5°C
Display: Four-digit LED display
Display Resolution: 0.1°C
Number of Samples: Up to 3 samples simultaneously
Fast Ramp Rate: Fixed at 20°C/min
Slow Ramp Rate: Adjustable from 0.2°C/min to 10°C/min (in 0.1°C/min increments)
Cooling Rate: Internal fan with a cooling rate of 25°C/min
Cooling Process: Automatically starts after the analysis ends; fan turns off when temperature reaches 5°C below fast stage temperature
Dual Display: Inside and outside displays for ease of use, reducing the need to frequently switch between eyepiece and external display
Handheld “READ” Push Button: Allows users to quickly record data without having to search for the “READ” button on the main unit
Data Recording: Data is stored permanently until manually erased
“Read” Button: Simultaneously holds the melting point reading and heating process
Calibration: Supports chemical calibration or external probe calibration
Specifications :
Technical specification:
| Model | AE-HMPD-100 | AE-HMPD200 | AE-HMPD300 |
| Temperature range (ºC ) | Ambient to 300 | Ambient to 350 | Ambient to 400 |
| Temperature accuracy (ºC ) | ± 0.5 | ± 0.5 | ± 0.5 |
| Display | Four digit LED | Four digit LED | Four digit LED |
| Display resolution (ºC ) | 0.1 | 0.1 | 0.1 |
| Readout and temperature hold | Yes | Yes | Yes |
| Calibration Capability | Yes | Yes | Yes |
| Number of samples | 3 | 3 | 3 |
| Fast Stage Ramp rate (ºC/min ) | 20 fixed | 20 fixed | 20 fixed |
| Slow Ramp rates (ºC/min ) | adjustable between 0.2 to 10 at 0.1 (ºC/min ) interval | adjustable between 0.2 to 10 at 0.1 (ºC/min ) interval | adjustable between 0.2 to 10 at 0.1 (ºC/min ) interval |
| Cooling rate (ºC/min ) | - | - | 25 |
| Inside Block Temperature View | No | No | Yes |
| Hand held “READ” push button | No | No | Yes |
| Data Recording | No | No | Yes |
| Dimensions (w x d x h) | No | 160 x 220 x 170mm | 160 x 220 x 170mm |
| Net weight | 222*190*200 | 1.8 Kg | 1.8 Kg |
| Electrical supply | 2.5 Kg | 120 or 230V, 50Hz, 75W | 120 or 230V, 50Hz, 75W |
Technical specification:
| Model | AE-HMPD-100 | AE-HMPD200 | AE-HMPD300 |
| Temperature range (ºC ) | Ambient to 300 | Ambient to 350 | Ambient to 400 |
| Temperature accuracy (ºC ) | ± 0.5 | ± 0.5 | ± 0.5 |
| Display | Four digit LED | Four digit LED | Four digit LED |
| Display resolution (ºC ) | 0.1 | 0.1 | 0.1 |
| Readout and temperature hold | Yes | Yes | Yes |
| Calibration Capability | Yes | Yes | Yes |
| Number of samples | 3 | 3 | 3 |
| Fast Stage Ramp rate (ºC/min ) | 20 fixed | 20 fixed | 20 fixed |
| Slow Ramp rates (ºC/min ) | adjustable between 0.2 to 10 at 0.1 (ºC/min ) interval | adjustable between 0.2 to 10 at 0.1 (ºC/min ) interval | adjustable between 0.2 to 10 at 0.1 (ºC/min ) interval |
| Cooling rate (ºC/min ) | - | - | 25 |
| Inside Block Temperature View | No | No | Yes |
| Hand held “READ” push button | No | No | Yes |
| Data Recording | No | No | Yes |
| Dimensions (w x d x h) | No | 160 x 220 x 170mm | 160 x 220 x 170mm |
| Net weight | 222*190*200 | 1.8 Kg | 1.8 Kg |
| Electrical supply | 2.5 Kg | 120 or 230V, 50Hz, 75W | 120 or 230V, 50Hz, 75W |
Download catalog for: