AELAB Bath Circulators AE-BC Series | Precise Temperature Control

The AELAB AE-BC Series bath circulators deliver precise temperature control with ±0.05°C stability, ideal for scientific and industrial applications. Equipped with a powerful pump and intuitive PID control, they ensure uniform liquid circulation and safe operation for accurate experimental results.

Modles : AE-BC206E~AE-BC213E~AE-BC217E~AE-BC220E~AE-BC227E
whatsapp Whatsapp

A bath circulator is a device used in laboratories and industrial settings to precisely control the temperature of liquids in baths or tanks. It consists of a heating and cooling system, a pump, and a temperature controller. The liquid to be heated or cooled is circulated through the bath or tank by the pump, ensuring uniform temperature distribution. This equipment is crucial for experiments and processes that require stable and controlled temperatures, such as chemical reactions, biological studies, and material testing. Bath circulators come in various sizes and configurations to accommodate different volumes and temperature ranges, offering flexibility and accuracy in temperature control for scientific and industrial applications.

 

Key features

  • “E”Models with single calibration point and maximum 100°C
  • PID I control with 士05Cstability
  • Splash-proof keypad with large and bright display, easy operation, 0.1 display solution
  • Heating function combined with pump for internal and external circulating
  • Powerful pump with pressure/suction function
  • Drain tap easily accessible;
  • Class ll safety protection: low liquid buoyage, and software overtemperature protection,suitable for inflammable liquid;
  • 3 operating models for different applications

 

🔬 How It Works?

The AE-BC Series bath circulators use an integrated heating and cooling system combined with a powerful pump to circulate liquid inside a bath or an external tank. The PID controller monitors and maintains temperature within ±0.05°C by adjusting the heater output precisely. The pump ensures uniform distribution of the temperature-controlled liquid, critical for consistent experimental conditions. Safety features like software overtemperature protection and low liquid buoyancy sensors enhance reliability.

 

💡 Advantages

  • Highly Stable Temperature Control: Achieve ±0.05°C precision, ensuring consistent experimental conditions.

  • Versatile Pump Operation: Supports both pressure and suction modes for internal or external circulation.

  • User-Friendly Interface: Splash-proof keypad with bright display for easy operation and monitoring.

  • Safety First: Class II protection and overtemperature safeguards allow safe use with flammable liquids.

  • Flexible Models: Multiple bath volumes and opening sizes accommodate varied laboratory and industrial needs.

 

🔍 Recommended Models by Use Case

  • AE-BC206E & AE-BC213E: Ideal for small-scale educational labs or research requiring compact setups.

  • AE-BC217E & AE-BC220E: Suitable for advanced research centers and QC labs with medium-volume applications.

  • AE-BC227E: Best for industrial labs and applications needing larger bath volumes and higher flow rates.

 

🧪 Ideal For

  • Chemical reaction temperature control

  • Biological sample incubation

  • Material testing requiring precise thermal environments

  • Quality control departments in pharmaceuticals and food industries

  • Educational laboratories requiring reliable and safe temperature management

Specifications :

Model T

emp.Range[°C]

Temp.Stability[°C] Heating Capacity

[W]

Pump Flow rate[L/min] Pump Pressure[bar] Pump Suction[bar] Bath Volume[L] Bath Opening

W*D*H[mm]

Dimensions

W*D*H[mm]

AE-BC206E RT+10···100 ±0.05 2000 12 0.2 0.1 6.0 150X105X150 180X330X400
AE-BC213E RT+10···100 ±0.05 2000 12 0.2 0.1 13.0 295x130x150 330x360x450
AE-BC217E RT+10···100 ±0.05 2000 22 0.3 0.2 17.0 295x130x200 330x360x450
AE-BC220E RT+10···100 ±0.05 2000 22 0.3 0.2 20.0 295x295x150 335x540x450
AE-BC227E RT+10···100 ±0.05 2000 22 0.3 0.2 27.0 295x295x200 335x540x450
Model T

emp.Range[°C]

Temp.Stability[°C] Heating Capacity

[W]

Pump Flow rate[L/min] Pump Pressure[bar] Pump Suction[bar] Bath Volume[L] Bath Opening

W*D*H[mm]

Dimensions

W*D*H[mm]

AE-BC206E RT+10···100 ±0.05 2000 12 0.2 0.1 6.0 150X105X150 180X330X400
AE-BC213E RT+10···100 ±0.05 2000 12 0.2 0.1 13.0 295x130x150 330x360x450
AE-BC217E RT+10···100 ±0.05 2000 22 0.3 0.2 17.0 295x130x200 330x360x450
AE-BC220E RT+10···100 ±0.05 2000 22 0.3 0.2 20.0 295x295x150 335x540x450
AE-BC227E RT+10···100 ±0.05 2000 22 0.3 0.2 27.0 295x295x200 335x540x450

Frequently Asked Questions

1How is calibration done?
Calibration is performed via the single calibration point on the “E” models, ensuring accurate temperature readings using standard reference sensors.
2Is the device GMP compliant?
Yes, the AE-BC Series meets GMP standards with Class II safety and software protections for safe laboratory use.
3How long is the warranty?
AELAB offers a standard 12-month warranty covering defects and performance issues under normal laboratory conditions.

Request Quote: AELAB Bath Circulators AE-BC Series | Precise Temperature Control