info@aelabgroup.com
QR Code 1
QR Code 2

AELAB Cooling Incubator AE-LB80 | Precision Temperature-Controlled Storage

The AELAB AE-LB80 Cooling Incubator provides precise temperature regulation from 0–60 °C for laboratory cultivation, microbiology testing, and controlled sample storage. Its stainless steel chamber, forced-air convection, and microprocessor LCD control ensure stable, uniform thermal performance suitable for long-duration analytical workflows.
Modles : AE-L/ LB Series
whatsapp Whatsapp

The AELAB AE-LB80 Cooling Incubator is designed for automatic hot and cold regulation using a high-precision microprocessor temperature controller with a large LCD display. The polished stainless steel chamber and adjustable shelves provide excellent durability and easy cleaning. An internal power outlet allows convenient operation of small laboratory instruments.

The AE-LB80 is equipped with an internal lamp for clear observation and a forced-convection fan system that ensures stable airflow. The inner door uses tempered glass for easy viewing, while the magnetic-sealed outer door maintains strong thermal insulation. A spare temperature control system protects the chamber in the event of a primary controller failure.

 

⚙️ Design & Construction

The AE-LB80 Cooling Incubator features a fully polished Stainless Steel chamber engineered for high chemical resistance and easy sanitation. The double-door configuration integrates a tempered-glass inner door for sample monitoring without temperature loss. Forced-air convection ensures uniform temperature distribution across the 80 L chamber, while the insulated outer door maintains thermal stability. R134a refrigerant supports energy-efficient, fluorine-free cooling performance.

 

🔬 Working Principle / Testing Method

The AE-LB80 regulates chamber temperature through a microprocessor-controlled heating and cooling system operating between 0–60 °C. The controller stabilizes the chamber using ±0.5 °C heating accuracy and ±1 °C cooling accuracy, while uniformity of ±1 °C ensures reproducible incubation. Forced-air convection distributes conditioned air evenly across shelves, supporting microbiological culture, stability testing, seed germination studies, and biochemical sample preservation.

 

💡 Key Advantages

  • Stable thermal control with ±1 °C temperature uniformity for consistent incubation.
  • Large LCD controller for precise digital monitoring and programming.
  • Forced-air convection improves chamber recovery after door openings.
  • Tempered-glass inner door allows observation without disturbing internal temperature.
  • Fluorine-free R134a refrigerant supports environmentally compliant cooling.
  • Internal chamber power outlet enables operation of small auxiliary devices.
  • Spare temperature controller ensures uninterrupted operation during primary control failure.

 

🔗 Connectivity & Integration

The AE-LB80 includes an RS485 communication interface for GLP-compliant data transfer to a computer or external printer. Temperature, timing, and operational records can be exported for traceability, reporting, or laboratory documentation workflows.

 

🧠 Model Insight

Model Key Specifications
AE-LB80 80 L chamber volume; 0–60 °C range; 180 W power; 40×37×55 cm chamber size; ±1 °C uniformity
AE-LB150 150 L; 0–60 °C; 250 W; 45×42×85 cm; ±1 °C uniformity
AE-LB200 200 L; 0–60 °C; 300 W; 45×45×100 cm; ±1 °C uniformity

 

🧪 Testing Applications

The AE-LB80 Cooling Incubator is suitable for microbiological cultivation, plant and seed germination studies, enzyme storage, pharmaceutical stability testing, biochemical sample preservation, and general laboratory incubation requiring precise 0–60 °C thermal control.

 

Compliance & Quality Assurance

The AELAB AE-LB80 adheres to ISO, CE, and GLP laboratory equipment standards. All units undergo factory calibration and quality verification to ensure stable long-term operation and reproducible temperature performance.

Specifications :

Model AE-LB80
Chamber Volume 80L
Temperature Range 0~60 °C
Display Resolution 0.1 °C
Temperature Stability Heating: ±0.5 °C; Cooling: ±1 °C
Temperature Uniformity ±1 °C
Timing Range 1~9999 min
Power Rating (W) 180
Refrigerant R134a
Power Supply 220±10% 50Hz
Continuous Operation Long continuous operation
Chamber Size (W×D×H) cm 40×37×55
Exterior Size (W×D×H) cm 54×57×107
Shelf (Std/Max) 2/8
Model AE-LB80
Chamber Volume 80L
Temperature Range 0~60 °C
Display Resolution 0.1 °C
Temperature Stability Heating: ±0.5 °C; Cooling: ±1 °C
Temperature Uniformity ±1 °C
Timing Range 1~9999 min
Power Rating (W) 180
Refrigerant R134a
Power Supply 220±10% 50Hz
Continuous Operation Long continuous operation
Chamber Size (W×D×H) cm 40×37×55
Exterior Size (W×D×H) cm 54×57×107
Shelf (Std/Max) 2/8

Frequently Asked Questions

1Does the AE-LB80 support data export?
Yes. It includes an RS485 interface for connection to PC software or printers.
2What is the operating temperature range?
The AE-LB80 provides a precise 0–60 °C temperature range.
3How uniform is the temperature inside the chamber?
Temperature uniformity is ±1 °C with forced-air convection.
4Can the unit run continuously?
Yes. The AE-LB80 supports long continuous operation and includes a spare safety temperature controller.

Request Quote: AELAB Cooling Incubator AE-LB80 | Precision Temperature-Controlled Storage