The AE-TGA125 measures mass changes of materials during heating or cooling to assess thermal stability, composition, and decomposition. It’s used in plastics, drugs, catalysts, and more for analyzing moisture, volatiles, and reaction behavior with high precision.
The AE-TGA125 Thermo Gravimetric Analyzer is designed to measure material weight changes under controlled temperature conditions. It analyzes thermal stability, decomposition, and composition of materials across a wide range of industries, including polymers, pharmaceuticals, and composites. Key functions include studying oxidation/reduction, moisture content, filler effects, and reaction kinetics. With high sensitivity and precision, it supports R&D, quality control, and process optimization.
Features:
Specifications :
| 1 | Temperature range | And ~ 1,250℃ at room temperature |
| 2 | Temperature resolution | 0.01℃ |
| 3 | Temperature fluctuation | ±0.01℃ |
| 4 | Heating rate | 0.1~100℃/min |
| 5 | Scale measurement range | 0.01mg-5g |
| 6 | Quality resolution | 0.01mg |
| 7 | The constant temperature time | 0~500min (arbitrary set) |
| 8 | Cooling-off period | 30min(1000℃…100℃) |
| 9 | Toggle rate | 16.6Hz |
| 10 | Sampling rate | 0.05~10Hz can program setting |
| 11 | Experimental mode | FTC, STC mode are arbitrarily set |
| 12 | Type of experiment | Weight loss and weight gain (adsorption) |
| 13 | Procedure temperature control | The whole stage is 12 order temperature control flexible setting |
| 14 | Temperature control mode | Heat up, constant temperature, and cooling |
| 15 | Cycle index | The number of cycle scans can be set up to 9999, and the data is automatically saved |
| 16 | Instrument calibration | Both the lower computer and the upper computer have a multi-point temperature correction function |
| 17 | Display mode | 24bit color 7-inch LCD touchscreen display |
| 18 | Atmosphere control | Two atmosphere can be set freely, the instrument will automatically switch |
| 19 | Parameter standard | Equipped with the standard material, the user can correct the temperature by himself |
| 20 | Source | AC220V / 50Hz (customizable AC110V) |
| 1 | Temperature range | And ~ 1,250℃ at room temperature |
| 2 | Temperature resolution | 0.01℃ |
| 3 | Temperature fluctuation | ±0.01℃ |
| 4 | Heating rate | 0.1~100℃/min |
| 5 | Scale measurement range | 0.01mg-5g |
| 6 | Quality resolution | 0.01mg |
| 7 | The constant temperature time | 0~500min (arbitrary set) |
| 8 | Cooling-off period | 30min(1000℃…100℃) |
| 9 | Toggle rate | 16.6Hz |
| 10 | Sampling rate | 0.05~10Hz can program setting |
| 11 | Experimental mode | FTC, STC mode are arbitrarily set |
| 12 | Type of experiment | Weight loss and weight gain (adsorption) |
| 13 | Procedure temperature control | The whole stage is 12 order temperature control flexible setting |
| 14 | Temperature control mode | Heat up, constant temperature, and cooling |
| 15 | Cycle index | The number of cycle scans can be set up to 9999, and the data is automatically saved |
| 16 | Instrument calibration | Both the lower computer and the upper computer have a multi-point temperature correction function |
| 17 | Display mode | 24bit color 7-inch LCD touchscreen display |
| 18 | Atmosphere control | Two atmosphere can be set freely, the instrument will automatically switch |
| 19 | Parameter standard | Equipped with the standard material, the user can correct the temperature by himself |
| 20 | Source | AC220V / 50Hz (customizable AC110V) |