The torque of the gossamer, the shape of the rotor, the size of the rotation speed, and the range of the viscosity measurement are the same as the same viscometer imported, and the measured viscosity data is very well comparable with the imported similar instruments.Widely used in paint, paint, cosmetics, ink, pulp, food, oil products, starch, adhesives, latex, biochemical products and other industries. It can also be optional high temperature furnace measurement need heating melt samples such as asphalt, hot melt glue, polyethylene wax and other samples.
Features:
Specifications :
| Model | LVDV-1 | LVDV-2 |
| Show | liquid crystal display | |
| Speed(r/min) | 0.3 – 100 37 RPM | 0.1-200 58 RPM |
|
Measuring range |
1 - 2,000,000 mPa.s | 1 - 6,000,000 mPa.s |
| ULR / ULR PLUS should be selected for measuring the ultra-low viscosity below 10 | ||
|
Sample dosage |
1-4 Rotor:300-400ml
18,25,31,34Rotor:7-11ml; ULR: 21ml |
|
| Measurement error | ±1% (Newtonian liquid) | |
| Repetitive error | ±0.3% (Newtonian liquid) | |
| Showing the shear response / shear rate | standard configuration | |
| Timed function | standard configuration | |
| Temperature measurement function | Standard temperature probe interface (optional temperature probe is required) | |
| Automatic scanning function | Automatically scan and recommend a preferential combination of the rotor and the rotational speed | |
| Maximum measurement range | Automatically displays the measurable viscosity range of the selected rotor and speed | |
| Print function | Data and curve printable (standard printing interface, printer) | |
| data output interface | Two USB interfaces to printer and computer | |
| Thermostatic parts | Options (including special thermostatic slot for various viscosity meters, constant temperature cup) | |
| Working power supply | 110V/60Hz or 220V/50Hz) | |
| Outline dimension | 300 × 300 × 450 (mm) | |
| Model | LVDV-1 | LVDV-2 |
| Show | liquid crystal display | |
| Speed(r/min) | 0.3 – 100 37 RPM | 0.1-200 58 RPM |
|
Measuring range |
1 - 2,000,000 mPa.s | 1 - 6,000,000 mPa.s |
| ULR / ULR PLUS should be selected for measuring the ultra-low viscosity below 10 | ||
|
Sample dosage |
1-4 Rotor:300-400ml
18,25,31,34Rotor:7-11ml; ULR: 21ml |
|
| Measurement error | ±1% (Newtonian liquid) | |
| Repetitive error | ±0.3% (Newtonian liquid) | |
| Showing the shear response / shear rate | standard configuration | |
| Timed function | standard configuration | |
| Temperature measurement function | Standard temperature probe interface (optional temperature probe is required) | |
| Automatic scanning function | Automatically scan and recommend a preferential combination of the rotor and the rotational speed | |
| Maximum measurement range | Automatically displays the measurable viscosity range of the selected rotor and speed | |
| Print function | Data and curve printable (standard printing interface, printer) | |
| data output interface | Two USB interfaces to printer and computer | |
| Thermostatic parts | Options (including special thermostatic slot for various viscosity meters, constant temperature cup) | |
| Working power supply | 110V/60Hz or 220V/50Hz) | |
| Outline dimension | 300 × 300 × 450 (mm) | |
Download catalog for: