AELAB AQMS-450 Carbon Dioxide Analyzer – Precision CO₂ Monitoring System

The AELAB AQMS-450 Carbon Dioxide Analyzer provides precise CO₂ concentration measurement using Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR) technology. Engineered for environmental monitoring, HVAC system validation, and industrial safety, it delivers accurate, low-noise readings with advanced purging and anti-corrosion optical design for stable long-term performance.



Modles : AQMS-450
whatsapp Whatsapp

The AELAB AQMS-450 Carbon Dioxide Analyzer is a precision instrument engineered for real-time CO₂ quantification in ambient and industrial air environments. Utilizing Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR) detection, it ensures highly accurate, low-drift, and interference-free performance for applications in environmental monitoring, HVAC validation, and industrial air safety compliance.

 

⚙ Design & Construction

The AQMS-450 features a white cavity optical chamber combined with an anti-corrosion surface treatment for long-term operational stability. An integrated CO₂ purging device minimizes ambient gas interference, while the precision optical path and signal filtering enhance sensitivity and reduce background noise. Its modular design supports easy maintenance, and the compact rack-mounted form factor enables installation in laboratory benches or mobile monitoring stations.

 

🔬 Working Principle / Testing Method

The AELAB AQMS-450 operates on the GFC-NDIR principle, where infrared radiation passes through a gas filter correlation wheel that alternates between CO₂-absorbing and non-absorbing paths. The difference in detected light intensity corresponds to the CO₂ concentration in the sample gas. This method effectively eliminates cross-sensitivity to other gases, providing precise and repeatable results even in variable environmental conditions. Temperature and pressure are continuously compensated by the onboard processor to maintain measurement integrity.

 

💡 Key Advantages

  • Wide measurement range (up to 2000 ppm) suitable for ambient and industrial monitoring.
  • Ultra-low detection limit of <0.2 ppm for sensitive CO₂ analysis.
  • White cavity design and anti-corrosion optics for long-term operational stability.
  • Automatic calibration and intelligent data management with real-time alarms.
  • Multi-protocol digital outputs (RS232, RS485, Ethernet) for flexible connectivity.
  • Low power consumption for efficient, continuous operation.
  • Compact design supporting laboratory, field, and HVAC system integration.

 

🔗 Connectivity & Integration

The analyzer includes RS232, RS485, and Ethernet interfaces for direct connection to SCADA systems, data loggers, and environmental monitoring networks. Analog 4–20 mA output enables integration with control systems or process automation platforms. Classified operation allows automatic data storage, alarm activation, and calibration data retention, ensuring uninterrupted traceability and compliance with air quality management standards.

 

🧠 Model Insight

The AELAB AQMS-450 represents a precise and reliable CO₂ analyzer built for advanced laboratories and environmental agencies. Its enhanced purging and optical stabilization technologies minimize external interferences while maintaining accuracy across extended operation periods. The model supports multiple configurations, including field-deployable and network-integrated versions for regional air quality networks or industrial emission monitoring.

 

🧪 Testing Applications

  • Environmental monitoring networks measuring CO₂ and greenhouse gas emissions.
  • Indoor air quality evaluation and HVAC performance assessment.
  • Industrial process safety and workplace air quality compliance.
  • CO₂ emission control in power generation and manufacturing sectors.
  • Green building certification and smart ventilation studies.
  • Academic and research laboratory analysis of atmospheric CO₂ trends.

 

Compliance & Quality Assurance

The AELAB AQMS-450 Carbon Dioxide Analyzer complies with ISO 9001 and CE environmental monitoring standards. It supports calibration against certified reference gases, ensuring traceability and repeatable measurement performance. Each analyzer undergoes rigorous quality inspection under controlled laboratory conditions, aligning with GLP and EPA-equivalent testing requirements for environmental data collection and industrial compliance verification.

 

Specifications :

Feature Details
Measurement Principle Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR)
Measurement Range 0–2000 ppm
Lower Detectable Limit <0.2 ppm
Zero Noise Negligible
Span Noise ≤5 ppm
Zero Drift (24 h) ±0.25 ppm
Span Drift (24 h) 1% of reading
Precision ≤5 ppm
Response Time ≤90 s (T90)
Sample Flow Rate 800 cm³/min ±10%
Data Transmission 4–20 mA analog output
Output RS232, RS485, Ethernet
Power Requirement AC 220 V, 50 Hz, ≤350 W
Operating Temperature 0–40 °C
Operating Humidity 0–95% RH (non-condensing)
Dimensions 178(H) × 432(W) × 604(D) mm
Weight ≤28 kg
Accessories Power cable, communication cables, calibration documentation
Feature Details
Measurement Principle Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR)
Measurement Range 0–2000 ppm
Lower Detectable Limit <0.2 ppm
Zero Noise Negligible
Span Noise ≤5 ppm
Zero Drift (24 h) ±0.25 ppm
Span Drift (24 h) 1% of reading
Precision ≤5 ppm
Response Time ≤90 s (T90)
Sample Flow Rate 800 cm³/min ±10%
Data Transmission 4–20 mA analog output
Output RS232, RS485, Ethernet
Power Requirement AC 220 V, 50 Hz, ≤350 W
Operating Temperature 0–40 °C
Operating Humidity 0–95% RH (non-condensing)
Dimensions 178(H) × 432(W) × 604(D) mm
Weight ≤28 kg
Accessories Power cable, communication cables, calibration documentation

Frequently Asked Questions

1What detection method does the AELAB AQMS-450 use?
It operates using Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR) technology for high-accuracy CO₂ measurement.
2What is the minimum detectable CO₂ concentration?
The AQMS-450 can detect CO₂ levels as low as 0.2 ppm.
3Does the instrument compensate for environmental changes?
Yes, it features automatic temperature and pressure compensation for stable readings.
4Can the analyzer connect to data systems?
Yes, it supports RS232, RS485, Ethernet, and 4–20 mA outputs for network integration.
5What are the main applications of the AQMS-450?
It is ideal for environmental monitoring stations, HVAC validation, industrial air safety, and CO₂ emission research.
6How does the AELAB AQMS-450 minimize CO₂ interference?
It includes a built-in purging system that removes environmental CO₂ interference for improved accuracy.

Request Quote: AELAB AQMS-450 Carbon Dioxide Analyzer – Precision CO₂ Monitoring System