The AELAB A3G Atomic Absorption Spectrophotometer is a graphite furnace system for ultra-trace metal quantification. A fixed, transversely heated tube with precision feedback control, dual background correction (D2 and self-reversal), and an automatic 8-lamp turret deliver stable, reproducible results. AA-Win 3.0 software manages methods, calibration, and data, supporting environmental, clinical, pharmaceutical, and materials testing workflows.
The AELAB A3G Atomic Absorption Spectrophotometer is a graphite furnace platform for quantitative determination of metals at trace and ultra-trace levels. By dedicating the optical path to a transversely heated graphite tube with precision feedback, the AELAB A3G maximizes furnace stability and minimizes drift, enabling reliable results in environmental, clinical, pharmaceutical, and materials analysis.
The A3G employs a computer-controlled Czerny–Turner monochromator with an 1800 grooves/mm diffraction grating across 185–910 nm. Software-selectable bandwidths (0.1/0.2/0.4/1.0/2.0 nm), wavelength accuracy of ±0.15 nm, reproducibility <0.05 nm, and baseline stability of 0.005 Abs/30 min support consistent signal capture. An automatic 8-lamp turret streamlines element changes. The graphite head is fixed in the optical path, and pyrolytically coated platform tubes improve atomization uniformity and reduce matrix effects.
In graphite furnace AAS, microliter volumes are introduced into a transversely heated tube and processed through drying, ashing, atomization, and cleaning steps. The AELAB A3G supports up to 10 programmed steps from ambient to 3000 °C with voltage and optical temperature feedback. Typical performance includes a Cd detection limit <0.004 ng/mL and Cu sensitivity 50 ng/mL >0.40 Abs. Dual background correction—deuterium (D2) and self-reversal (SR)—extends accuracy in complex matrices.
AA-Win 3.0 software manages instrument setup, calibration (multi-standard, standard addition, interpolation), method storage, and result archiving. Data records include analytical results, instrument parameters, signal profiles, and calibration curves. Communication port type is not specified in the provided data and should be confirmed for LIMS/printer integration.
Within the A3 Series, the AELAB A3G focuses on graphite furnace workflows where pg–ng/mL detection is required. For laboratories needing both routine and ultra-trace analysis, the A3FG variant adds a flame path with automatic atomizer changeover under AA-Win 3.0 control.
The AELAB A3G supports GLP-style recordkeeping through controlled methods and auditable data storage. Optical performance (wavelength accuracy, bandwidth control) and programmable furnace steps enable validated, repeatable protocols for regulated and research laboratories.
Specifications :
| Feature | Details |
|---|---|
| Capacity | Graphite furnace atomic absorption for trace/ultra-trace elements |
| Readability | Cd detection limit <0.004 ng/mL; Cu sensitivity 50 ng/mL >0.40 Abs; Repeatability ≤2.0% (Cu, Cd) |
| Units | ng/mL, µg/L (concentration by calibration curve) |
| Platform Size | Graphite furnace only; transversely heated tube, fixed in optical path |
| Display | PC control via AA-Win 3.0 (Windows) |
| Interface | PC-based operation (ports not specified) |
| Power | Main unit: 220 VAC, 50/60 Hz; Graphite PSU: 220 VAC, 50/60 Hz, instantaneous 7 kW |
| Battery | Not applicable |
| Calibration | Multi-standard calibration, standard addition, interpolation; automatic wavelength scan/positioning |
| Output | Stores results, parameters, signal profile, calibration curve; report generation in AA-Win 3.0 |
| Dimensions | Main unit: 110 × 54 × 54 cm; Graphite PSU: 50 × 54 × 54 cm |
| Weight | Main unit: 75 kg; Graphite PSU: 70 kg |
| Construction | Czerny–Turner monochromator; 1800 grooves/mm grating; blaze 250 nm; bandwidths 0.1/0.2/0.4/1.0/2.0 nm; single-beam; pyrolytically coated platform tubes |
| Operating Conditions | Not specified |
| Accessories | Included: manuals, validation documents, 8 lamp holders, power cables, tool kit, fittings, argon tubing, connection cable, 10 graphite tubes, pipette & tips |
| Feature | Details |
|---|---|
| Capacity | Graphite furnace atomic absorption for trace/ultra-trace elements |
| Readability | Cd detection limit <0.004 ng/mL; Cu sensitivity 50 ng/mL >0.40 Abs; Repeatability ≤2.0% (Cu, Cd) |
| Units | ng/mL, µg/L (concentration by calibration curve) |
| Platform Size | Graphite furnace only; transversely heated tube, fixed in optical path |
| Display | PC control via AA-Win 3.0 (Windows) |
| Interface | PC-based operation (ports not specified) |
| Power | Main unit: 220 VAC, 50/60 Hz; Graphite PSU: 220 VAC, 50/60 Hz, instantaneous 7 kW |
| Battery | Not applicable |
| Calibration | Multi-standard calibration, standard addition, interpolation; automatic wavelength scan/positioning |
| Output | Stores results, parameters, signal profile, calibration curve; report generation in AA-Win 3.0 |
| Dimensions | Main unit: 110 × 54 × 54 cm; Graphite PSU: 50 × 54 × 54 cm |
| Weight | Main unit: 75 kg; Graphite PSU: 70 kg |
| Construction | Czerny–Turner monochromator; 1800 grooves/mm grating; blaze 250 nm; bandwidths 0.1/0.2/0.4/1.0/2.0 nm; single-beam; pyrolytically coated platform tubes |
| Operating Conditions | Not specified |
| Accessories | Included: manuals, validation documents, 8 lamp holders, power cables, tool kit, fittings, argon tubing, connection cable, 10 graphite tubes, pipette & tips |
No download files available for this product.