The AELAB A3FG Atomic Absorption Spectrophotometer is an advanced dual-mode analytical system integrating both Flame and Graphite Furnace Atomisers. It provides high accuracy and sensitivity for trace metal quantification across environmental, pharmaceutical, agricultural, and industrial applications. Controlled by the intelligent AA-Win 3.0 software, the A3FG offers full automation, method flexibility, and GLP-compliant data handling for precise elemental measurement.
The A3FG model features a precision optical system with 1800 grooves/mm diffraction grating, 250nm blaze wavelength, and computer-controlled Czerny–Turner monochromator. The chassis is fabricated from corrosion-resistant metal with ergonomic front-panel access. The instrument houses an 8-lamp turret, high-intensity Deuterium Arc lamp for background correction, and a fully automatic flame and graphite atomizer switch.
The system performs atomic absorption analysis using either the Air/Acetylene or N2O/Acetylene flame, and transversely heated graphite furnace for ultra-trace detection. The optical beam passes through the atomized sample, and the AA-Win 3.0 software calculates absorbance, transmittance, and concentration values. High-resolution wavelength selection (0.1–2.0nm) and optical feedback loops ensure exceptional measurement reproducibility and low noise stability (0.005Abs/30min).
The A3FG connects to standard PCs running Windows OS. The AA-Win 3.0 software enables real-time signal acquisition, calibration curve display, and data storage in multi-format outputs. Analytical results, method files, and calibration reports can be exported via USB or LAN for traceability and regulatory compliance.
| Model | Configuration | Atomizers | Features |
|---|---|---|---|
| A3F | Flame Only | Air/Acetylene | Standard burner, automatic lamp control |
| A3G | Graphite Furnace | Graphite Atomizer | Transversely heated furnace, precise temperature feedback |
| A3FG | Flame + Graphite Furnace | Dual Atomizer | Automatic atomizer switch, advanced AA-Win 3.0 integration |
The AELAB A3FG Atomic Absorption Spectrophotometer is ideal for quantifying trace elements in agricultural, environmental, food, mining, pharmaceutical, petrochemical, and metallurgical samples. It supports absorbance and emission analysis, enabling accurate detection of metals such as Cu, Zn, Pb, Fe, and Cd in diverse matrices.
The A3FG complies with ISO, CE, and GLP laboratory standards. Each instrument undergoes calibration verification and QC validation to ensure analytical precision and reproducibility under certified AELAB production protocols.
Specifications :
| Spectrometer System | |
|---|---|
| Wavelength Range | 185nm – 910nm |
| Light Source | Hollow Cathode Lamp (HCL), Deuterium Arc Lamp (D2) |
| Modulation | Square Wave Pulse |
| Modulation Frequency | 100Hz Self Reversal (SR) background, 400Hz Deuterium Arc (D2) background |
| Monochromator | |
| Grating | 1800 grooves/mm diffraction grating |
| Blazed Wavelength | 250nm |
| Focus | 300mm |
| Bandwidth | 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable) |
| Scan Mode | Automatic |
| Photometric Type | Single Beam |
| Wavelength Accuracy | ±0.15nm |
| Wavelength Resolution | 0.2nm ± 0.02nm |
| Wavelength Reproducibility | <0.05nm |
| Baseline Stability | 0.005Abs/30min |
| Background Correction | Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs |
| Flame Analysis | |
| Flame Types | Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG) |
| Sensitivity (Cu) | 2µg/ml Absorption >0.28Abs |
| Characteristic Concentration | Cu <0.02µg/ml, Ba <0.15µg/ml (N2O/Acetylene) |
| Detection Limit | Cu <0.004µg/ml |
| Repeatability | Cu <0.7% (Air/Acetylene Flame), Ba <1.0% (N2O/Acetylene Flame) |
| Burner Heads | Titanium Alloy |
| Nebuliser | High Efficiency Glass, Acid-Proof Option Available |
| Pre-mix Chamber | Corrosion Resistant |
| Atomiser Selection | Automatic Changeover (A3FG) |
| Safety Features | Burner Identification, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor, Drain Trap, Power Loss Protection |
| Graphite Furnace Analysis | |
| Graphite Head | Transversally Heated |
| Temperature Range | Ambient – 3000°C |
| Heating Program | Up to 10 Steps: Drying, Ashing, Atomisation, Cleaning |
| Feedback | Voltage and Optical Temperature Control Feedback |
| Sensitivity (Cu) | 50ng/ml Absorption >0.40Abs |
| Detection Limit | Cd <0.004ng/ml |
| Repeatability | Cu <2.0%, Cd <2.0% |
| Graphite Tubes | Pyrolytically Coated with Platform |
| Sample Size | Up to 20µl |
| Graphite Cooling | Water Circulator Available |
| Safety Features | Argon Pressure Sensor, Water Flow Sensor, Over Temperature Sensor, Broken Tube Protection |
| Data Processing | |
| PC System | PC, Windows Operating System |
| Operating Program | AA-Win 3.0 Software |
| Analytical Methods | Flame AA, Flame AE, Graphite Furnace, Hydride Generation |
| Readout Mode | Continuous, Peak Height, Peak Area |
| Calibrations | Multi-Standard Calibration, Standard Addition, Interpolation |
| Data Storage | Analytical Results, Instrument Parameters, Signal Profile, Calibration Curve |
| Power Requirements | |
| Main Unit | 220VAC 50/60Hz |
| Graphite Power Supply | 220VAC 50/60Hz, Instantaneous Power 7KW |
| Dimensions | |
| Main Unit | 110cm × 54cm × 54cm, 75kg |
| Graphite Power Supply | 50cm × 54cm × 54cm, 70kg |
| Spectrometer System | |
|---|---|
| Wavelength Range | 185nm – 910nm |
| Light Source | Hollow Cathode Lamp (HCL), Deuterium Arc Lamp (D2) |
| Modulation | Square Wave Pulse |
| Modulation Frequency | 100Hz Self Reversal (SR) background, 400Hz Deuterium Arc (D2) background |
| Monochromator | |
| Grating | 1800 grooves/mm diffraction grating |
| Blazed Wavelength | 250nm |
| Focus | 300mm |
| Bandwidth | 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable) |
| Scan Mode | Automatic |
| Photometric Type | Single Beam |
| Wavelength Accuracy | ±0.15nm |
| Wavelength Resolution | 0.2nm ± 0.02nm |
| Wavelength Reproducibility | <0.05nm |
| Baseline Stability | 0.005Abs/30min |
| Background Correction | Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs |
| Flame Analysis | |
| Flame Types | Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG) |
| Sensitivity (Cu) | 2µg/ml Absorption >0.28Abs |
| Characteristic Concentration | Cu <0.02µg/ml, Ba <0.15µg/ml (N2O/Acetylene) |
| Detection Limit | Cu <0.004µg/ml |
| Repeatability | Cu <0.7% (Air/Acetylene Flame), Ba <1.0% (N2O/Acetylene Flame) |
| Burner Heads | Titanium Alloy |
| Nebuliser | High Efficiency Glass, Acid-Proof Option Available |
| Pre-mix Chamber | Corrosion Resistant |
| Atomiser Selection | Automatic Changeover (A3FG) |
| Safety Features | Burner Identification, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor, Drain Trap, Power Loss Protection |
| Graphite Furnace Analysis | |
| Graphite Head | Transversally Heated |
| Temperature Range | Ambient – 3000°C |
| Heating Program | Up to 10 Steps: Drying, Ashing, Atomisation, Cleaning |
| Feedback | Voltage and Optical Temperature Control Feedback |
| Sensitivity (Cu) | 50ng/ml Absorption >0.40Abs |
| Detection Limit | Cd <0.004ng/ml |
| Repeatability | Cu <2.0%, Cd <2.0% |
| Graphite Tubes | Pyrolytically Coated with Platform |
| Sample Size | Up to 20µl |
| Graphite Cooling | Water Circulator Available |
| Safety Features | Argon Pressure Sensor, Water Flow Sensor, Over Temperature Sensor, Broken Tube Protection |
| Data Processing | |
| PC System | PC, Windows Operating System |
| Operating Program | AA-Win 3.0 Software |
| Analytical Methods | Flame AA, Flame AE, Graphite Furnace, Hydride Generation |
| Readout Mode | Continuous, Peak Height, Peak Area |
| Calibrations | Multi-Standard Calibration, Standard Addition, Interpolation |
| Data Storage | Analytical Results, Instrument Parameters, Signal Profile, Calibration Curve |
| Power Requirements | |
| Main Unit | 220VAC 50/60Hz |
| Graphite Power Supply | 220VAC 50/60Hz, Instantaneous Power 7KW |
| Dimensions | |
| Main Unit | 110cm × 54cm × 54cm, 75kg |
| Graphite Power Supply | 50cm × 54cm × 54cm, 70kg |
Download catalog for: