The AELAB AA-7020 Series Atomic Absorption Spectrometer provides dual flame and graphite furnace functionality within a compact, fully integrated analytical system. It is engineered for high-precision metal element determination in metallurgy, petrochemical, environmental, and food science laboratories. The instrument ensures excellent optical stability and trace-level detection for over 70 elements.
The AA-7020 Series features a C-T grating optical system with an 1800 lines/mm diffraction grating, automatic bandwidth switching, and Titanium burners. The frame integrates both flame and graphite furnace assemblies, with independent power control and safety protection. The housing is fabricated from corrosion-resistant alloy materials, ensuring long-term stability under demanding laboratory conditions.
The instrument operates on the atomic absorption principle using both flame and electrothermal atomization. The flame system supports air-acetylene and nitrous oxide operation, while the graphite furnace method achieves atomization temperatures up to 3000 °C. Dual background correction—Deuterium lamp and self-absorption—is applied for accurate trace metal quantification. The optical layout ensures repeatable wavelength calibration and superior baseline stability.
The AELAB AA-7020 includes Ethernet and computer connectivity for data communication, with support for PC workstation software, calibration storage, and result printing. USB and optional printer interfaces are available for GLP-compliant reporting and data archiving.
| Model | Main Configuration | Key Features |
|---|---|---|
| AA-7022 | Flame atomizer, fast wavelength scan, six-lamp rotating turret | Deuterium background correction, self-absorption correction, Ethernet communication |
| AA-7023 | Flame and graphite furnace integration | Automatic switching, water-cooled graphite furnace, hydride generator compatibility |
The AELAB AA-7020 Series is suitable for trace metal determination in metallurgy, petrochemical production, environmental protection, food safety, agricultural testing, disease control, and material science laboratories. It quantifies metals such as As, Pb, Cd, Hg, Se, Sb, and Ni at trace concentrations with reliable precision.
The AA-7020 Series complies with ISO and CE laboratory safety standards and supports GLP-traceable calibration. Each instrument undergoes strict optical alignment, background correction validation, and stability testing before delivery under AELAB’s certified quality system.
Specifications :
| Optical System | |
|---|---|
| Wavelength Range | 190–900 nm |
| Mono-Chromator | C-T Grating Mono-Chromator |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.05 nm |
| Grating | 1800 lines/mm |
| Spectral Bandwidth | Automatic switching between 5 levels: 0.1, 0.2, 0.4, 1.0, 2.0 nm |
| Blaze Wavelength | 250 nm |
| Baseline Stability | ±0.003 A/30 min (Static), ±0.002 A/30 min (Dynamic) |
| Resolution | Better than 0.1 nm |
| Flame Method | |
|---|---|
| Benchmark Concentration of Cu | 0.02 g/mL |
| Detection Limit | 0.003 g/mL |
| Precision RSD | 0.6% |
| Burner | Interchangeable full Titanium burner of 50 mm and 100 mm |
| Position Adjustment | Adjustable height and angle Flame to hydride can be Detection Limit:0.003 g/ml Burner:Interchangeable full titanium burner of 50mm and 100 mm switched in less than 1 minute |
| Graphite Furnace Method | |
|---|---|
| Benchmark Concentration of Cd | 0.3 × 10⁻¹² g |
| Detection Limit | 0.2 × 10⁻¹² g |
| Precision RSD | 2% |
| Temperature Range | Room Temperature to 3000 °C |
| Temperature Control Program | Max 20-step temperature program, 3 modes of temperature (step, slope, flat) |
| Optical Control Temperature Rise Rate | 3000 °C/s |
| Heating Modes | Max power heating and optical control rapid heating |
| Max Power Temperature Rise Rate | 2000 °C/s |
| General Configuration | |
|---|---|
| Main Unit Dimensions | 880 (L) × 540 (W) × 450 (H) mm |
| Main Unit Power | 200 W |
| Graphite Furnace Power | 4 kW |
| Power Supply | ~220 V 50 Hz single phase |
| Weight | 125 kg |
| Optical System | |
|---|---|
| Wavelength Range | 190–900 nm |
| Mono-Chromator | C-T Grating Mono-Chromator |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.05 nm |
| Grating | 1800 lines/mm |
| Spectral Bandwidth | Automatic switching between 5 levels: 0.1, 0.2, 0.4, 1.0, 2.0 nm |
| Blaze Wavelength | 250 nm |
| Baseline Stability | ±0.003 A/30 min (Static), ±0.002 A/30 min (Dynamic) |
| Resolution | Better than 0.1 nm |
| Flame Method | |
|---|---|
| Benchmark Concentration of Cu | 0.02 g/mL |
| Detection Limit | 0.003 g/mL |
| Precision RSD | 0.6% |
| Burner | Interchangeable full Titanium burner of 50 mm and 100 mm |
| Position Adjustment | Adjustable height and angle Flame to hydride can be Detection Limit:0.003 g/ml Burner:Interchangeable full titanium burner of 50mm and 100 mm switched in less than 1 minute |
| Graphite Furnace Method | |
|---|---|
| Benchmark Concentration of Cd | 0.3 × 10⁻¹² g |
| Detection Limit | 0.2 × 10⁻¹² g |
| Precision RSD | 2% |
| Temperature Range | Room Temperature to 3000 °C |
| Temperature Control Program | Max 20-step temperature program, 3 modes of temperature (step, slope, flat) |
| Optical Control Temperature Rise Rate | 3000 °C/s |
| Heating Modes | Max power heating and optical control rapid heating |
| Max Power Temperature Rise Rate | 2000 °C/s |
| General Configuration | |
|---|---|
| Main Unit Dimensions | 880 (L) × 540 (W) × 450 (H) mm |
| Main Unit Power | 200 W |
| Graphite Furnace Power | 4 kW |
| Power Supply | ~220 V 50 Hz single phase |
| Weight | 125 kg |
Download catalog for: