The AELAB Tissue Stainer YD-700 is a high-performance automatic stainer designed for precise and efficient tissue sample preparation in histology labs. With 18 cylinders, advanced ion purification, and a user-friendly LCD interface, it ensures reliable results while protecting operators from harmful vapors. Compact yet powerful, it is an ideal solution for modern laboratories seeking productivity and safety.
The Tissue Stainer YD-700 is designed for efficient staining of tissue samples in histology. It features multiple staining stations, allowing for simultaneous processing of several samples. The user-friendly interface simplifies operation and monitoring.
With precise temperature control and adjustable timing, the YD-700 ensures consistent and high-quality staining results. Its compact design makes it suitable for various lab settings, enhancing workflow and productivity in tissue preparation.
Features:
1.Can continuously run the dye box
Multiple staining racks can be run at the same time for continuous batch dyeing
(Can meet large quantities of work)
2.Color LCD touch screen display
Icon display, showing all operating parameters, intuitive and clear. Can directly modify the parameters on the icon display, touch screen operation, Commonly used reagents such as xylene, which volatilizes in the air, are harmful to the human body. Commonly used air purification uses activated carbon adsorption purification, that is, physical purification. Activated carbon purification requires a certain adsorption temperature (60 °C ~ 70 °C in the first stage, 20 °C ~ 40 °C in the second stage) and a certain adsorption time (1 hour or so) to completely remove. The moisture and dust in the air will affect the activity of activated carbon, thus affecting its effectiveness, so it must be replaced or regenerated.
3.Ion purification can overcome the above drawbacks.
Ion purifying produces ions by ionizing gases, changing and decomposing harmful gases (hydrocarbons) that can completely remove harmful substances without maintenance
4.Six programs can be stored
Six common operating procedures can be stored.
5.Automatic location memory function
Each time it runs automatically, it can find the starting position and memorize it to ensure that the wrong cylinder phenomenon does not occur in each run, and each cylinder uses a separate positioning method to increase the positioning accuracy.
6.With alarm function, such as the dyeing rack into the end of the cylinder, the front staining rack is still not taken away at the end of the cylinder, there is an alarm to promptly handle.
7.Anti-card cylinder function
8.With drying cylinder
9.Automatic water inlet, drainage
Automatic water drainage, with overflow protection
10.The running parts adopt bearing linear guides, which have high precision, low resistance, stable operation and wear resistance, and can maintain their reliability for a long time.
The YD-700 Tissue Stainer automates the histological staining process by moving tissue slides through a series of reagent cylinders. Each cylinder’s timing and temperature can be customized, ensuring reproducible and consistent staining results. Unlike traditional air purification methods, the YD-700 uses ion purification technology, which decomposes harmful vapors like xylene into harmless compounds—eliminating the need for frequent maintenance.
High Throughput: Process multiple baskets simultaneously for continuous, large-scale staining.
Enhanced Safety: Ion purification removes harmful vapors, providing a safer lab environment compared to activated carbon filters.
User-Friendly: Color LCD touchscreen with intuitive icon-based operation.
Programmable Efficiency: Save up to 6 staining protocols for quick setup and repeatability.
Reliability: Automatic position memory, anti-jam cylinder design, and alarm system ensure smooth and error-free operation.
Durability: Precision bearing linear guides ensure stable, long-lasting performance.
Educational & Teaching Labs: Ideal for consistent routine slide preparation with easy operation.
Hospital Pathology Labs: Suitable for medium to high-volume diagnostic staining.
Research Institutions: Flexible programming allows for specialized staining protocols.
Quality Control Departments: Reliable automation improves reproducibility and reduces human error.
Histology and pathology labs
Medical research institutes
University teaching laboratories
Clinical diagnostic centers
Biopharmaceutical R&D facilities
Specifications :
| Number of cylinders | 18 |
| (One cleaning cylinder, one drying cylinder) | |
| Capacity | 1000ml |
| (Single basket 47 slides)(double baskets run together will be 94 slides) | |
| Operation mode | Running multiple baskets continuously |
| (Continuous batch dyeing) | |
| Set time per cylinder | 1 second~99 minutes 59 seconds |
| Set temperature | 0°C~99°C |
| Storable program | 6 sets |
| The basket rises and trembles | 0-10 times |
| Dimensions | 140x50x55cm |
| Number of cylinders | 18 |
| (One cleaning cylinder, one drying cylinder) | |
| Capacity | 1000ml |
| (Single basket 47 slides)(double baskets run together will be 94 slides) | |
| Operation mode | Running multiple baskets continuously |
| (Continuous batch dyeing) | |
| Set time per cylinder | 1 second~99 minutes 59 seconds |
| Set temperature | 0°C~99°C |
| Storable program | 6 sets |
| The basket rises and trembles | 0-10 times |
| Dimensions | 140x50x55cm |
Download catalog for: