AELAB AA-7050 Series Atomic Absorption Spectrophotometer | Flame & Graphite Furnace

The AELAB AA-7050 Series Atomic Absorption Spectrophotometer integrates flame and graphite furnace systems for precise quantitative analysis of over 70 elements. Featuring automatic lamp alignment, deuterium background correction, and full PC control, the AA-7050 ensures high stability and sensitivity for trace metal determination across laboratory and industrial environments.
Modles : AA-7050 Series
whatsapp Whatsapp

The AELAB AA-7050 Series Atomic Absorption Spectrophotometer combines precision optical performance with advanced automation for elemental analysis across scientific, environmental, and industrial laboratories. Designed to measure more than 70 elements at both trace and macro concentrations, it provides reliable performance for metallurgy, petrochemical, and environmental applications.

 

⚙️ Design & Construction

The AA-7050 Series features a compact and stable optical bench with C-T grating mono-chromator and 1800 lines/mm diffraction grating for enhanced resolution. The instrument’s unique suspension design isolates the optical system from vibration and temperature variation. The integrated flame and graphite furnace atomizer is housed within a single enclosure, with automatic deuterium lamp background correction and high-stability power regulation.

 

🔬 Working Principle / Testing Method

The system operates on the principle of atomic absorption spectrometry. It quantifies elemental concentrations by measuring absorbance at element-specific wavelengths between 190 – 900 nm. Automated flame and graphite switching allows continuous analysis without optical realignment. A deuterium lamp compensates for molecular background absorption, while multi-step graphite temperature control achieves atomization up to 3000 °C for trace-level detection.

 

💡 Key Advantages

  • Automatic wavelength positioning and slit switching within 40 seconds
  • Automated flame height and lamp current optimization for best sensitivity
  • Deuterium lamp background correction and self-absorption reduction
  • Multi-element sequence analysis for up to 8 elements automatically
  • Graphite furnace camera system for real-time monitoring of atomization
  • Temperature correction programs extending graphite tube lifespan to >1000 firings
  • Under-pressure and over-heating protection for complete operator safety

 

🔗 Connectivity & Integration

The AA-7050 Series supports full PC operation via dedicated AELAB software, with USB data export and GLP-compliant reporting. Calibration curves, spectra, and analysis logs can be automatically saved and printed. Optional integration modules include the HG-01 Hydride Generator, AS-600 Auto-Sampler, and EW-320AC Air Compressor.

 

🧠 Model Insight

Model Explanation
AA-7050 Flame atomizer with integrated graphite furnace
AA-7050F Flame atomizer only
AA-7050G Graphite furnace atomizer

 

🧪 Testing Applications

The AELAB AA-7050 Series is used for trace metal determination in environmental water, soil, petrochemical, and food samples. It also supports research in metallurgy, agricultural nutrient studies, pharmaceutical quality control, and toxicological analysis of heavy metals such as Pb, As, Cd, Hg, Sb, and Se.

 

Compliance & Quality Assurance

Manufactured under ISO 9001 quality management and CE safety standards, the AELAB AA-7050 ensures full traceability of calibration and operational performance. All instruments are factory-calibrated and validated under GLP laboratory protocols.

Specifications :

Optical System
Wavelength Range 190–900 nm Spectral Bandwidth Automatic switching between 5 levels: 0.1, 0.2, 0.4, 1.0, 2.0 nm
Mono-Chromator C-T Grating Mono-Chromator Wavelength Accuracy ±0.1 nm
Wavelength Repeatability ≤0.05 nm Grating 1800 lines/mm
Blaze Wavelength 250 nm Baseline Stability ≤0.003A/30 min (Static), ≤0.002A/30 min (Dynamic)
Resolution Better than 0.1 nm
Flame Method
Benchmark Concentration of Cu ≤0.02 μg Detection Limit ≤0.003 μg/ml
Precision RSD ≤0.6% Burner Interchangeable full titanium burner of 50 mm and 100 mm
Position Adjustment Adjustable height and angle; flame to hydride switch in less than 1 minute
Graphite Furnace Method
Benchmark Concentration of Cd 0.3×10⁻⁹ g Detection Limit 0.2×10⁻⁹ g
Temperature Range Room temperature to 3000 °C Precision RSD ≤1.8%
Temperature Control Program Max 20 step temperature program, 3 modes: step, slope, flat Optical Control Temperature Rise Rate ≥3000 °C/s
Max Power Temperature Rise Rate ≥2000 °C/s Heating Modes Max power heating and optical control rapid heating
Accuracy ≤1% Reproducibility ≤0.5%
Data Processing & Power Supply
Measurement Methods Flame absorption, flame emission, graphite furnace, and hydride method
Analysis Method Linear fitting, nonlinear fitting, standard addition method
Output Calibration curve, spectrum, analysis parameters, auto data storage & print
Dimensions 880 (L) × 540 (W) × 450 (H) mm Weight 125 kg
Main Unit Power 200 W Graphite Furnace Power 4 kW
Power Supply ~220 V 50 Hz single phase
Optical System
Wavelength Range 190–900 nm Spectral Bandwidth Automatic switching between 5 levels: 0.1, 0.2, 0.4, 1.0, 2.0 nm
Mono-Chromator C-T Grating Mono-Chromator Wavelength Accuracy ±0.1 nm
Wavelength Repeatability ≤0.05 nm Grating 1800 lines/mm
Blaze Wavelength 250 nm Baseline Stability ≤0.003A/30 min (Static), ≤0.002A/30 min (Dynamic)
Resolution Better than 0.1 nm
Flame Method
Benchmark Concentration of Cu ≤0.02 μg Detection Limit ≤0.003 μg/ml
Precision RSD ≤0.6% Burner Interchangeable full titanium burner of 50 mm and 100 mm
Position Adjustment Adjustable height and angle; flame to hydride switch in less than 1 minute
Graphite Furnace Method
Benchmark Concentration of Cd 0.3×10⁻⁹ g Detection Limit 0.2×10⁻⁹ g
Temperature Range Room temperature to 3000 °C Precision RSD ≤1.8%
Temperature Control Program Max 20 step temperature program, 3 modes: step, slope, flat Optical Control Temperature Rise Rate ≥3000 °C/s
Max Power Temperature Rise Rate ≥2000 °C/s Heating Modes Max power heating and optical control rapid heating
Accuracy ≤1% Reproducibility ≤0.5%
Data Processing & Power Supply
Measurement Methods Flame absorption, flame emission, graphite furnace, and hydride method
Analysis Method Linear fitting, nonlinear fitting, standard addition method
Output Calibration curve, spectrum, analysis parameters, auto data storage & print
Dimensions 880 (L) × 540 (W) × 450 (H) mm Weight 125 kg
Main Unit Power 200 W Graphite Furnace Power 4 kW
Power Supply ~220 V 50 Hz single phase

Frequently Asked Questions

1What is the detection limit of the AELAB AA-7050 Series?
Detection limits reach ≤0.003 μg/ml for Cu in flame mode and 0.2×10⁻⁹ g for Cd in graphite furnace mode.
2Can the AA-7050 switch between flame and graphite automatically?
Yes, automated or manual switching can be completed in less than 2 seconds without optical adjustment.
3Does the instrument include background correction?
Yes, deuterium lamp and optional self-absorption background correction are supported.
4Is there an auto-sampler option?
Yes, optional AS-600 or AS-200 automatic samplers are available for both flame and furnace operations.
5What are the operating conditions?
The system operates reliably at 10 – 40 °C, under non-condensing humidity with stable power supply (220 V, 50 Hz).