Single Beam UV-VIS Spectrophotometer N4S/N4/N2S/N2

The AELAB Single Beam UV-VIS Spectrophotometer (N4S/N4/N2S/N2) combines advanced ARM core technology, offering high-speed testing and reliable performance. It covers the visible and UV-visible spectral range, making it ideal for quantitative analysis in medicine, biochemistry, petrochemicals, environmental protection, and academic research. This versatile instrument is designed for both routine and specialized laboratory use.
Modles : N4S、N4、N2S、N2
whatsapp Whatsapp

N series spectrophotometer, being combined with and ARM processed core, has test speeds and functions possessed by high-end instruments. The instrument can meet the requirement of quantitative analysis for most samples conducted within the visible and ultraviolet-visible spectral range in concentional laboratories and is suitable for use in medicine and health, clinical examination, biochemical, petrochemical, environmental protection, quality contraol departments, colleges and universities and others.

 

Features:

  • Automatic setting wavelength 7 inch multi color touch screen
  • Sample compartment for 5-50mm cuvettes Equipped with USB port
  • Precise automatic T/A changeover Automatic zero and full scale adjustment
  • Direct concentration read-out and concentration factor setting function

 

Specifications :

Model N4S N4 N2S N2
Photometry Single Beam
Monochromator Type Czerny-Turner
Focal Length 160mm
Grating 1200 lines/mm
Detector Silicon Photocell
Spectrum Bandwidth 2nm 4nm
Wavelength Range 190-1100nm 325-1100nm
Wavelength Accuracy ± 1nm
Wavelength Repeatability ≤ 0.5nm
Photometric Range 0.0 ~ 200.0% T ; -0.301 ~ 4.000A ; 0.000 to 9999C
Photometric Accuracy ± 0.3% T ; ± 0.002Abs (0 - 0.5A) ± 0.004Abs (0.5 - 1A) ± 0.5% T
Photometric Repeatability ≤ 0.15% T ; 0.001Abs (0 - 0.5A) 0.002Abs (0.5 - 1A) ≤ 0.2% T
Wavelength Scanning Speed Fast, medium, slow --- Fast, medium, slow ---
Baseline ≤±0.003A(200-1090nm) --- ≤±0.003A(335-1090nm) ---
Built in Printer YES NO YES NO
Stray Light ≤ 0.1% ( at 220 nm NaI ; at 360 nm NaNO₂) ≤ 0.1% T(measured at NaNO₂ at 360 nm)
Noise 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)
Baseline Drift ± 0.002 Abs / 30 mins (250nm and 500nm

after preheat warm up for 2 hours )

± 0.002 Abs /30min

( 500nm after preheat warm up for 2 hours )

Power AC220v± 22v, 50Hz± 1Hz, 180W AC220v± 22v, 50Hz± 1Hz, 100W
Packing Size 630mm*610mm*500mm, 0.16m³,25kg.
Model N4S N4 N2S N2
Photometry Single Beam
Monochromator Type Czerny-Turner
Focal Length 160mm
Grating 1200 lines/mm
Detector Silicon Photocell
Spectrum Bandwidth 2nm 4nm
Wavelength Range 190-1100nm 325-1100nm
Wavelength Accuracy ± 1nm
Wavelength Repeatability ≤ 0.5nm
Photometric Range 0.0 ~ 200.0% T ; -0.301 ~ 4.000A ; 0.000 to 9999C
Photometric Accuracy ± 0.3% T ; ± 0.002Abs (0 - 0.5A) ± 0.004Abs (0.5 - 1A) ± 0.5% T
Photometric Repeatability ≤ 0.15% T ; 0.001Abs (0 - 0.5A) 0.002Abs (0.5 - 1A) ≤ 0.2% T
Wavelength Scanning Speed Fast, medium, slow --- Fast, medium, slow ---
Baseline ≤±0.003A(200-1090nm) --- ≤±0.003A(335-1090nm) ---
Built in Printer YES NO YES NO
Stray Light ≤ 0.1% ( at 220 nm NaI ; at 360 nm NaNO₂) ≤ 0.1% T(measured at NaNO₂ at 360 nm)
Noise 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)
Baseline Drift ± 0.002 Abs / 30 mins (250nm and 500nm

after preheat warm up for 2 hours )

± 0.002 Abs /30min

( 500nm after preheat warm up for 2 hours )

Power AC220v± 22v, 50Hz± 1Hz, 180W AC220v± 22v, 50Hz± 1Hz, 100W
Packing Size 630mm*610mm*500mm, 0.16m³,25kg.

Request Quote: Single Beam UV-VIS Spectrophotometer N4S/N4/N2S/N2