The AELAB OIC-M1 Ion Chromatograph delivers high-performance ion analysis with modular eluent generation and advanced degassing technology. Engineered for precision and flexibility, it supports multiple elution types and offers reliable, accurate results for research and quality control labs.
The AELAB OIC-M1 Ion Chromatograph is a high-performance analytical instrument designed for precise ion analysis. It features a modular built-in eluent generator that supports various types of elution, including hydroxyl, carbonate bicarbonate mixed, and methylsulfonic acid types. The system enables both isocratic and gradient elution by simply adding pure water and electrochemically generating the desired eluent concentration (0-100 mmol/L), with a flow rate of 0-5 ml/min and concentration accuracy of 0.1 mM/L. This ensures flexibility and reliability for different ion analysis needs.
Features:
The AELAB OIC-M1 operates by electrochemically generating eluents with a modular built-in generator, allowing for precise isocratic or gradient elution tailored to your ion analysis needs. The system continuously monitors pressure and eluent concentration in real-time to ensure stable flow and reliable separation. Its advanced degassing units prevent air bubbles from interfering with the flow path or pump operation. Samples are injected via an electronically controlled six-way valve, while continuous regeneration suppressors eliminate ionic interference. The high-sensitivity conductivity detector accurately measures ion concentrations, delivering repeatable and dependable results for complex analyses.
Versatile Eluent Generation: Electrolytic production of eluents for multiple ion types with customizable concentration and flow
Stable Operation: Advanced online degassing and pressure monitoring reduce downtime and extend pump life
High Precision: Ultra-sensitive detection with low baseline noise and drift, ensuring reliable data quality
Durability: Robust construction with PEEK materials and long-lasting components, including valves rated for 100,000+ cycles
Automated Maintenance: Leak detection and automatic cleaning prolong system life and reduce manual upkeep
User-Friendly: Integrated workstation for method saving, dynamic monitoring, and easy data handling
Educational Labs: Ideal for teaching advanced chromatographic techniques with simple eluent switching
Research Centers: Supports complex ion analysis with flexible elution and precise detection
Quality Control Departments: Ensures consistent, repeatable results for routine product and material testing
Environmental Labs: Suitable for water quality and pollutant ion monitoring with sensitive detection limits
Food safety and analysis labs
Pharmaceutical and chemical research
Environmental testing and monitoring
Industrial quality assurance
Clinical and biochemical laboratories
Specifications :
| AELAB OIC-M1 Parameter | |||
|
Appearance |
Integrated box design (Size:400mm×488mm×570mm) |
Main body: Metal plate | |
| Front door panel:ABS | |||
| Decoration panel:Acrylic | |||
| Design style:Orun integrated box style | |||
|
Structure |
Modular integration structure |
Eluent generator module | Eluent tank |
| High pressure online degassing & Ion capture CR-TC | |||
| Online degassing module | 1-4 channel negative pressure degasification | ||
| Leakage alarm module | Generator, pump, valve, pipeline, etc., with leakage alarm system | ||
| Automatic pump clean & External regenerated liquid module | Cleaning fluid pump | ||
| Regenerated liquid Pump | |||
|
Basic module |
Flow system (mobile phase and waste liquid bottles;
High pressure constant flow pump; pipeline and joints) |
||
| Sampling system (electric six-way valve; sample inlet; trigger unit) | |||
| Separation system (guard column and IC column) | |||
| Detection system (suppressor; detector) | |||
| Temperature control system (eluent preheating; column heating; detector temperature control) | |||
|
Host- computer |
Built-in chromatography workstation. Methods that can be saved and called | ||
|
Generator |
Can realize two elution modes:
isocratic and gradient; can monitor feedback pressure and concentration parameters in real time; can dynamically display operating status spectra and set line charts in real time; can save and call completed methods; can be implemented with the sampling system and acquisition system Synchronous cycle; has pressure loss self-protection function; |
Flow setting: 0=5ml/min, participate in current calculation | |
| Concentration setting: 0-100mM/L, participate in current calculation | |||
| Time setting: used for gradient elution, the time and concentration curve has two modes: mutation and gradient. | |||
| Pressure monitoring: real-time, better with monitoring curve (pressure data can be obtained from the high-pressure pump) Methods can be set, saved, called and changed (can be added to the total method) | |||
| Control (EG & CR-TC) power supply, when the pressure is lower than the specified value, the current will be stopped | |||
| After the injection, the workstation collects data simultaneously, and the generator method also starts a new cycle. | |||
| Low pressure online degassing: Pressure can be set; abnormal pressure alarm | |||
| Liquid leakage alarm: There are liquid leakage alarms and automatic stop functions for each module of the equipment. | |||
| Cleaning after pump | Online continuous cleaning & maintenance cleaning 2 modes | There are corresponding options and switch buttons | |
| Suppressor external regeneration fluid:
Self-regeneration/external regeneration: |
There are self-regeneration and external regeneration mode options | ||
|
High-pressure pump |
Flow setting: 0-10ml/min | ||
| Pressure monitoring: It is best to have a record curve chart | |||
| Gradual lifting and automatic switching program | |||
| Electric valve | Controllable state switching and trigger signal sending: Workstation acquisition, generator triggering | ||
| Suppressor | Suppressor current control: Current setting range: 0-350mA; Voltage loss self-protection power-off function (can be shared with the generator self-protection power-off condition) | ||
| Temperature control: Column oven and detection, chamber temperature setting and control | |||
|
Configu ratio n |
Modular build-in eluent generator |
Type | Hydroxyl type; Carbonate bicarbonate mixed type; Methylsulfonic acid type |
|
Function |
Isocratie elution and gradient elution can be achieved by simply adding pure water and continuously producing the desired concentration of eluent through electrolysis. | ||
| High pressure online degassing | |||
| Online ion capture | |||
| Elunet concentration | 0-100 mmol/L | ||
| Flow rate | 0-5 ml/min | ||
| Withstand voltage | 0-20Mpa | ||
| Concentration accuracy | 0. 1mM/L | ||
|
Modular build-in online negative pressure degasification |
Function |
Realize online degassing of the mobile phase, effectively preventing air bubbles from entering the pump and causing instability in the flow path or idling wear of the pump. | |
| Overpressure alarm (high pressure / low pressure) | |||
| Pressure setting(72000Pa-80000Pa) | |||
| Pressure monitoring | |||
| Expansion | 1-4 channel negative pressure degasification | ||
| Degassing efficiency | ≥90% | ||
| Degassing volume | ≥5ml | ||
| Leakage alarm | Generator, pump, valve, pipeline and other flow path components, leakage alarm function | ||
| Pump automatic cleaning | It can realize online automatic cleaning of the pump and automatic maintenance after the experiment. | ||
| External regenerator liquid | It can meet the needs of special experiments for external regeneration fluid of the suppressor. | ||
| High pressure constant current pump | Structure | Double plunger pulse series pump | |
| Material | Peek | ||
| Maximum withstand voltage | 42Mpa/6000Psi | ||
| Flow range | 0-9.999ml/min | ||
| Electronically controlled
automatic sampling six- way valve |
Structure | Peek | |
| Maximum withstand voltage | 42Mpa/6000Psi | ||
| Signal | Controllable by host computer; automatic trigger/switch trigger dual trigger mode | ||
| Longlife | The number of switching times is not less than 100,000 times | ||
| Chromatography column | N/A | ||
|
Supressor |
Structure | New filling processing structure, resistant to pressure and fabrication, long service life | |
| Supressor mode | Continuous regeneration micromembrane electrical suppression technology | ||
| Regeneration liquid Mode | Free choice of self-regeneration/external regeneration fluid | ||
| Supressor capacity | ≥200μeq | ||
| Volumn | ≤50μL | ||
|
New suppression/non - suppression universal conductivity detector |
Withstand voltage | 10Mpa | |
| Volumn | 0.5μL | ||
| Baseline noise | ≤0.5%FS或≤0.0005μS | ||
| Baseline drift | ≤10.0%FS/30min或≤0.01μS/30min | ||
| Detection limit | CL-≤0.001μg/ml Li+≤0.0005μg/ml | ||
| Linear | r>0.999 | ||
| Qualitative repeatability | RSD≤0.3% | ||
| Quantitative repeatability | RSD≤1.5% |
| AELAB OIC-M1 Parameter | |||
|
Appearance |
Integrated box design (Size:400mm×488mm×570mm) |
Main body: Metal plate | |
| Front door panel:ABS | |||
| Decoration panel:Acrylic | |||
| Design style:Orun integrated box style | |||
|
Structure |
Modular integration structure |
Eluent generator module | Eluent tank |
| High pressure online degassing & Ion capture CR-TC | |||
| Online degassing module | 1-4 channel negative pressure degasification | ||
| Leakage alarm module | Generator, pump, valve, pipeline, etc., with leakage alarm system | ||
| Automatic pump clean & External regenerated liquid module | Cleaning fluid pump | ||
| Regenerated liquid Pump | |||
|
Basic module |
Flow system (mobile phase and waste liquid bottles;
High pressure constant flow pump; pipeline and joints) |
||
| Sampling system (electric six-way valve; sample inlet; trigger unit) | |||
| Separation system (guard column and IC column) | |||
| Detection system (suppressor; detector) | |||
| Temperature control system (eluent preheating; column heating; detector temperature control) | |||
|
Host- computer |
Built-in chromatography workstation. Methods that can be saved and called | ||
|
Generator |
Can realize two elution modes:
isocratic and gradient; can monitor feedback pressure and concentration parameters in real time; can dynamically display operating status spectra and set line charts in real time; can save and call completed methods; can be implemented with the sampling system and acquisition system Synchronous cycle; has pressure loss self-protection function; |
Flow setting: 0=5ml/min, participate in current calculation | |
| Concentration setting: 0-100mM/L, participate in current calculation | |||
| Time setting: used for gradient elution, the time and concentration curve has two modes: mutation and gradient. | |||
| Pressure monitoring: real-time, better with monitoring curve (pressure data can be obtained from the high-pressure pump) Methods can be set, saved, called and changed (can be added to the total method) | |||
| Control (EG & CR-TC) power supply, when the pressure is lower than the specified value, the current will be stopped | |||
| After the injection, the workstation collects data simultaneously, and the generator method also starts a new cycle. | |||
| Low pressure online degassing: Pressure can be set; abnormal pressure alarm | |||
| Liquid leakage alarm: There are liquid leakage alarms and automatic stop functions for each module of the equipment. | |||
| Cleaning after pump | Online continuous cleaning & maintenance cleaning 2 modes | There are corresponding options and switch buttons | |
| Suppressor external regeneration fluid:
Self-regeneration/external regeneration: |
There are self-regeneration and external regeneration mode options | ||
|
High-pressure pump |
Flow setting: 0-10ml/min | ||
| Pressure monitoring: It is best to have a record curve chart | |||
| Gradual lifting and automatic switching program | |||
| Electric valve | Controllable state switching and trigger signal sending: Workstation acquisition, generator triggering | ||
| Suppressor | Suppressor current control: Current setting range: 0-350mA; Voltage loss self-protection power-off function (can be shared with the generator self-protection power-off condition) | ||
| Temperature control: Column oven and detection, chamber temperature setting and control | |||
|
Configu ratio n |
Modular build-in eluent generator |
Type | Hydroxyl type; Carbonate bicarbonate mixed type; Methylsulfonic acid type |
|
Function |
Isocratie elution and gradient elution can be achieved by simply adding pure water and continuously producing the desired concentration of eluent through electrolysis. | ||
| High pressure online degassing | |||
| Online ion capture | |||
| Elunet concentration | 0-100 mmol/L | ||
| Flow rate | 0-5 ml/min | ||
| Withstand voltage | 0-20Mpa | ||
| Concentration accuracy | 0. 1mM/L | ||
|
Modular build-in online negative pressure degasification |
Function |
Realize online degassing of the mobile phase, effectively preventing air bubbles from entering the pump and causing instability in the flow path or idling wear of the pump. | |
| Overpressure alarm (high pressure / low pressure) | |||
| Pressure setting(72000Pa-80000Pa) | |||
| Pressure monitoring | |||
| Expansion | 1-4 channel negative pressure degasification | ||
| Degassing efficiency | ≥90% | ||
| Degassing volume | ≥5ml | ||
| Leakage alarm | Generator, pump, valve, pipeline and other flow path components, leakage alarm function | ||
| Pump automatic cleaning | It can realize online automatic cleaning of the pump and automatic maintenance after the experiment. | ||
| External regenerator liquid | It can meet the needs of special experiments for external regeneration fluid of the suppressor. | ||
| High pressure constant current pump | Structure | Double plunger pulse series pump | |
| Material | Peek | ||
| Maximum withstand voltage | 42Mpa/6000Psi | ||
| Flow range | 0-9.999ml/min | ||
| Electronically controlled
automatic sampling six- way valve |
Structure | Peek | |
| Maximum withstand voltage | 42Mpa/6000Psi | ||
| Signal | Controllable by host computer; automatic trigger/switch trigger dual trigger mode | ||
| Longlife | The number of switching times is not less than 100,000 times | ||
| Chromatography column | N/A | ||
|
Supressor |
Structure | New filling processing structure, resistant to pressure and fabrication, long service life | |
| Supressor mode | Continuous regeneration micromembrane electrical suppression technology | ||
| Regeneration liquid Mode | Free choice of self-regeneration/external regeneration fluid | ||
| Supressor capacity | ≥200μeq | ||
| Volumn | ≤50μL | ||
|
New suppression/non - suppression universal conductivity detector |
Withstand voltage | 10Mpa | |
| Volumn | 0.5μL | ||
| Baseline noise | ≤0.5%FS或≤0.0005μS | ||
| Baseline drift | ≤10.0%FS/30min或≤0.01μS/30min | ||
| Detection limit | CL-≤0.001μg/ml Li+≤0.0005μg/ml | ||
| Linear | r>0.999 | ||
| Qualitative repeatability | RSD≤0.3% | ||
| Quantitative repeatability | RSD≤1.5% |
Download catalog for: