Desktop integrated design, beautiful appearance and easy operation. Oxygen nitrogen analyzer is an intelligent analytical instrument, which is composed of pulse furnace and computer, with pyroelectric sensor and thermal conductivity detector as the core.The instrument is mainly used for the analysis of oxygen content in metallurgy, machinery, commodity inspection, scientific research, chemical industry, ferrous metals, non – ferrous metals, rare earth metals, graphene, nano materials, new energy materials, copper alloys, superalloys, inorganic substances, ores, ceramics and other substances
Instrument composition
The ON-6801 combines a high-frequency electrode pulse furnace with advanced infrared and thermal conductivity detection systems. Once the sample is weighed using a high-precision balance, it’s heated in the pulse furnace. Released gases are transported by a high-purity carrier gas (He or Ar) and analyzed via a pyroelectric infrared sensor (for oxygen) and a thermal conductivity detector (for nitrogen). This setup ensures accurate separation, detection, and quantification within minutes.
✅ High Accuracy: Down to 0.00001% detection capability
✅ Dual Element Detection: Simultaneously analyze oxygen and nitrogen
✅ Fast & Flexible: Analysis time configurable from 2 to 4 minutes
✅ Advanced Interface: Touchscreen PC with specialized software
✅ Wide Application Scope: Handles various solid samples across industries
✅ Robust Build: Industrial-grade design with integrated balance and printer
✅ Desktop Design: Compact and lab-friendly footprint
🏫 Educational Labs: Ideal for teaching advanced elemental analysis techniques
🧪 Scientific Research Centers: ON-6801 excels in high-precision, multi-material analysis
🏭 Industrial Quality Control: For metallurgy, superalloys, and ceramic evaluation
⚗️ Chemical Analysis Facilities: Perfect for routine and advanced O/N testing
Metallurgical and alloy analysis
Ferrous and non-ferrous metals
Graphene and nanomaterials
Ceramics and oxides
Rare earth elements
Research in new energy materials
Commodity inspection and quality control
Specifications :
| Item | Details |
| Measuring Range | Oxygen: 0.00001% - 5% (expandable to 100%); Nitrogen: 0.00001% - 20% (expandable to 100%) |
| Instrument Accuracy | Oxygen: 1.0ppm or Relative Standard Deviation (RSD) ≤ 1.0%; Nitrogen: 1.0ppm or RSD ≤ 1.0% (based on solid standard sample, satisfying one of them) |
| Analysis Time | 120 - 240 seconds (can be set arbitrarily according to the analysis material) |
| Analysis Error | Nitrogen is superior to GB/T 20124 - 2006 |
| Carrier Gas | High - purity helium or argon (99.999%, 0.3 - 0.5mpa) |
| Power Gas | Ordinary nitrogen (or purified compressed air 0.3 - 0.5mpa) |
| Dimensions | W700mmx655mmxH860mm |
| Weight | 150kg |
| Weighing Accuracy of Electronic Balance | 0.0001g |
| Sample Weighing | 0.2 - 1.0g |
| Item | Details |
| Measuring Range | Oxygen: 0.00001% - 5% (expandable to 100%); Nitrogen: 0.00001% - 20% (expandable to 100%) |
| Instrument Accuracy | Oxygen: 1.0ppm or Relative Standard Deviation (RSD) ≤ 1.0%; Nitrogen: 1.0ppm or RSD ≤ 1.0% (based on solid standard sample, satisfying one of them) |
| Analysis Time | 120 - 240 seconds (can be set arbitrarily according to the analysis material) |
| Analysis Error | Nitrogen is superior to GB/T 20124 - 2006 |
| Carrier Gas | High - purity helium or argon (99.999%, 0.3 - 0.5mpa) |
| Power Gas | Ordinary nitrogen (or purified compressed air 0.3 - 0.5mpa) |
| Dimensions | W700mmx655mmxH860mm |
| Weight | 150kg |
| Weighing Accuracy of Electronic Balance | 0.0001g |
| Sample Weighing | 0.2 - 1.0g |