info@aelabgroup.com
QR Code 1
QR Code 2

Digital Abbe Refractometer (Standard) – AELAB

The AELAB WYA Series ABBE Digital Refractometer is designed for precision and reliability, offering fast, accurate measurements of refractive index (nD) and Brix values. The WYA-3S features a color LCD touch screen, temperature correction, and high precision, making it ideal for demanding applications in food, pharmaceutical, and chemical laboratories. The WYA-2S offers similar functionality in a more compact design with a slightly narrower temperature range, making it perfect for standard laboratory needs. Both models provide intuitive interfaces, making them trusted tools for analytical excellence across various industries.

Modles : WYA-3S~WYA-2S
whatsapp Whatsapp

AELAB ABBE Digital Refractometer WYA-3S/WYA-2S – High-Precision Refractive Index & Brix Measurement for Labs

The ABBE Digital Refractometer WYA Series is a high-precision instrument designed to measure the refractive index (nD) and Brix (mass percentage of sucrose, glucose, F42, F55 HFCS) of transparent and translucent liquids and solids. These refractometers are ideal for determining the dry solid content of fruit juices, vegetables, soft drinks, and canned goods.

WYA-3S:

The WYA-3S features a visual targeting system and a color LCD touch screen, providing a user-friendly, intuitive interface for easy operation and clear data interpretation. It is equipped with an imported LED light source that operates at a stable 589nm wavelength, ensuring long-term accuracy without temperature rise, high brightness, and energy efficiency. The instrument’s temperature correction function enhances measurement reliability, making it suitable for demanding applications in industries like food and beverage, pharmaceuticals, and chemical processing. The WYA-3S can store up to 500 sets of measurement data, making it easy to track and analyze results.

WYA-2S:

The WYA-2S is a slightly more compact model with similar features to the WYA-3S but designed for environments where slightly less extreme temperature tolerance is acceptable. With a measuring range of refractive index (nD) from 1.3000 to 1.7000 and a Brix range of 0-100%, this model is ideal for less demanding applications that still require high accuracy and ease of use. It is also equipped with a stable light source and temperature compensation, although it operates within a narrower temperature range (0-50°C) compared to the WYA-3S. The WYA-2S is suitable for labs and industries where standard refractive index and Brix measurements are essential but extreme precision is not required in temperature-sensitive conditions.

Common Features for Both Models:

  • Measurement of refractive index nD of transparent or translucent liquid and solid substances.

  • Measurement of Brix of sugar solutions.

  • Automatic temperature correction for the Brix to ensure accurate results.

  • Prism made of hard glass for durability and precision.

  • USB and RS232 interfaces for easy data transfer.

  • User-friendly color touch screen (for WYA-3S) and LCD display (for WYA-2S).


Recommended Models by Use Case:

  • 🍹 WYA-3S – Ideal for food & beverage labs analyzing sugar concentration, juice purity, and soft drinks.

  • 💊 Advanced WYA Series (contact AELAB) – For pharmaceutical R&D requiring tighter tolerances and automation.

  • ⚗️ Compact Series (alternative models) – Best for academic labs or portable field testing.


Ideal For:

  • Food & Beverage QC – Fruit juice, sugar solutions, canned goods

  • Pharmaceutical Analysis – Ingredient validation, purity control

  • Chemical Manufacturing – Concentration measurement in solutions

  • Research Laboratories – Academic and industrial applications needing high resolution

Specifications :

Parameters/Model WYA-3S WYA-2S
Measuring range Refractive index (nD): 1.30000-1.72000 Brix: 0-100% Refractive index (nD): 1.30000-1.70000 Brix: 0-100%
Measuring Accuracy Refractive index (nD): ±0.0002 Brix: ±0.1% Refractive index (nD): ±0.0002 Brix: ±0.1%
Resolution Refractive index (nD): 0.00001 Brix: 0.01% Refractive index (nD): 0.0001 Brix: 0.1%
Measuring methods 8 types /
Temp. display range -20-120°C (Min. 0.1°C) 0-50°C
Display Color touch screen LCD
Interface RS232, USB RS232
Date Storage 500 sets /
Power supply 220V±22V, 50Hz±1Hz, 30w
Overall dimensions 370mm×240mm×470mm
Weight (Gross) 10 kg
Parameters/Model WYA-3S WYA-2S
Measuring range Refractive index (nD): 1.30000-1.72000 Brix: 0-100% Refractive index (nD): 1.30000-1.70000 Brix: 0-100%
Measuring Accuracy Refractive index (nD): ±0.0002 Brix: ±0.1% Refractive index (nD): ±0.0002 Brix: ±0.1%
Resolution Refractive index (nD): 0.00001 Brix: 0.01% Refractive index (nD): 0.0001 Brix: 0.1%
Measuring methods 8 types /
Temp. display range -20-120°C (Min. 0.1°C) 0-50°C
Display Color touch screen LCD
Interface RS232, USB RS232
Date Storage 500 sets /
Power supply 220V±22V, 50Hz±1Hz, 30w
Overall dimensions 370mm×240mm×470mm
Weight (Gross) 10 kg

Frequently Asked Questions

1Can it measure solids as well as liquids?
Yes, the WYA-3S accurately measures both transparent and translucent liquids and solid samples.
2Is temperature compensation automatic?
Absolutely. The instrument includes automatic temperature correction for Brix readings.
3Can I export data for analysis?
Yes, measurement data can be stored and exported via RS232 or USB.
4Is the prism durable?
Yes, the prism is crafted from hard glass for long-term precision and durability.

Request Quote: Digital Abbe Refractometer (Standard) – AELAB