The Portable Digital Refractometer is a compact and user-friendly device designed for fast, accurate measurement of sugar content (Brix) in liquids. It features automatic temperature compensation for reliable results in varying environments and is suitable for applications in food, beverage, agriculture, and laboratories. With a rugged, water-resistant design and low sample volume requirement, this portable refractometer delivers quick readings and is ideal for both field and lab use.
Feature:
Fast and accurate Brix measurement
Automatic temperature compensation for reliable results
Compact and lightweight design, easy to carry and operate
Low sample volume requirement for efficient testing
Quick measurement time (around 2 seconds)
Water-resistant body (IP65) suitable for field use
Powered by a single AAA battery for convenience
Suitable for various applications including food, beverage, agriculture, and laboratories
🥤 Food & Beverage QA:
• AE-P101 / AE-P102 – General Brix & refractive index
• AE-P301 – Honey analysis with water content and °Be scales
• AE-P401 – Wine and fermentation testing
🌾 Agriculture & Field Use:
• AE-P104 / AE-P105 – Fructose & glucose testing in produce
• AE-P201 / AE-P202 – Soil and sea water salinity monitoring
🏥 Clinical & Research Labs:
• AE-P501 – Urine specific gravity, serum protein analysis
• AE-P103 / AE-P106 / AE-P107 – Sugar profiling (Dextran, Lactose, Maltose)
🚗 Industrial Applications:
• AE-P601 to AE-P604 – Automotive coolant, brake fluid, battery, and urea testing
This AELAB portable refractometer is perfect for:
🔬 Laboratories: Biotech, chemical, research, and quality control
🥫 Food & Beverage Industry: QC of sugar, honey, and alcohol content
🌿 Agricultural Testing: Ripeness, crop sugar levels, and irrigation salinity
🚙 Industrial & Automotive Fluids: Coolants, antifreeze, and battery fluids
🏥 Clinical Diagnostics: Urine and serum analysis
Specifications :
| Measurement range | Brix 0.0~50.0% &
Brix 0.0~90.0% |
Resolutions | (Brix) 0.1%
0.1℃ |
| Accuracy | (Brix) ±0.2%
±0.5℃ |
Environment Temperature | 0~40℃ |
| Measurement Temperature | 0~40℃ (ATC) | Sample volume needed | > 0.2ml |
| Measure time | 2S | Power Supply | 1 x AAA battery |
| Protection class | IP65 | Dim /G.W | 58(W)x25(D)x121(H)mm
90g(excluding battery) |
| Series | Model | Scale’s Name | Scale’s No. | Range | Resolution | Accuracy |
| Brix% | AE-P101 | Brix | S01 | 0.0-50.0% | 0.1% | ±0.2% |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P102 | Brix | S01 | 0.0-90.0% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD | ||
| AE-P103 | Dextran | S01 | 0.0-10.6% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P104 | Fructose | S01 | 0.0-68.9% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD | ||
| AE-P105 | Glucose | S01 | 0.0-59.9% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD | ||
| AE-P106 | Lactose | S01 | 0.0-16.5% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P107 | Maltose | S01 | 0.0-15.6% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| Salinity | AE-P201
(sodium chloride NaCl) |
Salinity | S01 | 0.0-28.0% | 0.1% | ±0.2% |
| Salinity | S02 | 0-280‰ | 1‰ | ±2‰ | ||
| Specific gravity | S03 | 1.000-1.217 | 0.001 | ±0.002 | ||
| Refractive Index | S04 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P202
(sea water) |
Salinity | S01 | 0-100‰ | 1‰ | ±2‰ | |
| Chlorinity | S02 | 0-57‰ | 1‰ | ±2‰ | ||
| Specific gravity | S03 | 1.000-1.070 | 0.001 | ±0.002 | ||
| Refractive Index | S04 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| Honey | AE-P301 | Brix | S01 | 0.0-90.0% | 0.1% | ±0.2% |
| Water | S02 | 38.0%-5.0% | 0.1% | ±0.2% | ||
| Be’ | S03 | 33.0-48.0 | 0.1 | ±0.2% | ||
| Refractive Index | S04 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD | ||
| Wine | AE-P401 | Brix% | S01 | 0.0-50.0% | 0.1% | ±0.2% |
| %VOLap | S02 | 0.0%-22.0% | 0.1% | ±0.2% | ||
| Oe | S03 | 0-150 | 1 | ±2% | ||
| KMW | S04 | 0.0-25.0 | 0.1 | ±0.2 | ||
| Clinical | AE-P501 | URINE SP. G. | S01 | 1.000-1.050 | 0.001 | ±0.002 |
| SERUM P. | S02 | -0.1-12.0 | 0.1 | ±0.2 | ||
| Refractive Index | S03 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| Car | AE-P601 | Cleaner | S01 | (0)-(-60)℃ | 0.1℃ | ±0.5℃ |
| Ethylene Glycol | S02 | (0)-(-60)℃ | 0.1℃ | ±0.5℃ | ||
| Propylene Glycol | S03 | (0)-(-70)℃ | 0.1℃ | ±0.5℃ | ||
| Battery | S04 | 1.000-1.500sg | 0.001 | ±0.005sg | ||
| AE-P602
(Urea Tester) |
Urea(NH2)2C0 | S01 | 0-51.0% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P603
(Engine Coolant Tester) |
Ethylene Glycol | S01 | 0-60% | 0.1% | ±0.5% | |
| Ethylene Glycol(℃) | S02 | (0)-(-60)℃ | 0.1℃ | ±0.5℃ | ||
| Propylene Glycol | S03 | 0-70% | 0.1% | ±0.5% | ||
| Propylene Glycol(℃) | S04 | (0)-(-70)℃ | 0.1℃ | ±0.5℃ | ||
| AE-P604
(Brake Fluid Tester) |
DOT3 | S01 | (121)-(260)℃ | 1℃ | ±0.5℃ | |
| DOT4 | S02 | (125)-(275)℃ | 1℃ | ±0.5℃ | ||
| Refractive Index | S03 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD |
| Measurement range | Brix 0.0~50.0% &
Brix 0.0~90.0% |
Resolutions | (Brix) 0.1%
0.1℃ |
| Accuracy | (Brix) ±0.2%
±0.5℃ |
Environment Temperature | 0~40℃ |
| Measurement Temperature | 0~40℃ (ATC) | Sample volume needed | > 0.2ml |
| Measure time | 2S | Power Supply | 1 x AAA battery |
| Protection class | IP65 | Dim /G.W | 58(W)x25(D)x121(H)mm
90g(excluding battery) |
| Series | Model | Scale’s Name | Scale’s No. | Range | Resolution | Accuracy |
| Brix% | AE-P101 | Brix | S01 | 0.0-50.0% | 0.1% | ±0.2% |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P102 | Brix | S01 | 0.0-90.0% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD | ||
| AE-P103 | Dextran | S01 | 0.0-10.6% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P104 | Fructose | S01 | 0.0-68.9% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD | ||
| AE-P105 | Glucose | S01 | 0.0-59.9% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD | ||
| AE-P106 | Lactose | S01 | 0.0-16.5% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P107 | Maltose | S01 | 0.0-15.6% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| Salinity | AE-P201
(sodium chloride NaCl) |
Salinity | S01 | 0.0-28.0% | 0.1% | ±0.2% |
| Salinity | S02 | 0-280‰ | 1‰ | ±2‰ | ||
| Specific gravity | S03 | 1.000-1.217 | 0.001 | ±0.002 | ||
| Refractive Index | S04 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P202
(sea water) |
Salinity | S01 | 0-100‰ | 1‰ | ±2‰ | |
| Chlorinity | S02 | 0-57‰ | 1‰ | ±2‰ | ||
| Specific gravity | S03 | 1.000-1.070 | 0.001 | ±0.002 | ||
| Refractive Index | S04 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| Honey | AE-P301 | Brix | S01 | 0.0-90.0% | 0.1% | ±0.2% |
| Water | S02 | 38.0%-5.0% | 0.1% | ±0.2% | ||
| Be’ | S03 | 33.0-48.0 | 0.1 | ±0.2% | ||
| Refractive Index | S04 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD | ||
| Wine | AE-P401 | Brix% | S01 | 0.0-50.0% | 0.1% | ±0.2% |
| %VOLap | S02 | 0.0%-22.0% | 0.1% | ±0.2% | ||
| Oe | S03 | 0-150 | 1 | ±2% | ||
| KMW | S04 | 0.0-25.0 | 0.1 | ±0.2 | ||
| Clinical | AE-P501 | URINE SP. G. | S01 | 1.000-1.050 | 0.001 | ±0.002 |
| SERUM P. | S02 | -0.1-12.0 | 0.1 | ±0.2 | ||
| Refractive Index | S03 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| Car | AE-P601 | Cleaner | S01 | (0)-(-60)℃ | 0.1℃ | ±0.5℃ |
| Ethylene Glycol | S02 | (0)-(-60)℃ | 0.1℃ | ±0.5℃ | ||
| Propylene Glycol | S03 | (0)-(-70)℃ | 0.1℃ | ±0.5℃ | ||
| Battery | S04 | 1.000-1.500sg | 0.001 | ±0.005sg | ||
| AE-P602
(Urea Tester) |
Urea(NH2)2C0 | S01 | 0-51.0% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| AE-P603
(Engine Coolant Tester) |
Ethylene Glycol | S01 | 0-60% | 0.1% | ±0.5% | |
| Ethylene Glycol(℃) | S02 | (0)-(-60)℃ | 0.1℃ | ±0.5℃ | ||
| Propylene Glycol | S03 | 0-70% | 0.1% | ±0.5% | ||
| Propylene Glycol(℃) | S04 | (0)-(-70)℃ | 0.1℃ | ±0.5℃ | ||
| AE-P604
(Brake Fluid Tester) |
DOT3 | S01 | (121)-(260)℃ | 1℃ | ±0.5℃ | |
| DOT4 | S02 | (125)-(275)℃ | 1℃ | ±0.5℃ | ||
| Refractive Index | S03 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD |
Download catalog for: