The AELAB Halogen Moisture Analyzer XY-MW Series is designed for fast, accurate determination of moisture content and dry residue across diverse materials. Featuring a high-efficiency halogen heating system, HBM precision sensor, and user-friendly LCD, this analyzer ensures consistent results for laboratories in food, pharmaceutical, agricultural, and chemical industries.
The XY-MW Series Halogen Moisture Analyzer is a reliable and versatile instrument designed for precise measurement of moisture content and dry residue in a wide range of materials. It features a high-efficiency halogen heating system and a sensitive HBM sensor for accurate, rapid drying and weighing.
Built with a durable aluminum shell and a stainless steel heating chamber, this series ensures stable thermal performance and long service life. The standard LCD display with a white backlight and black font offers clear readability, while the analyzer provides full temperature and time setting capabilities for tailored testing.
The XY-MW-A Series, an enhanced model, features a high-definition LCD and a highlight halogen lamp, delivering improved visibility and faster heating performance. Both versions support historical data storage, and calculate the percentage of moisture and dry content for repeatable, high-accuracy testing.
Optional accessories such as a printer, USB interface, aluminum transport box, and sample grinder expand functionality, making the XY-MW Series ideal for laboratories in food, pharmaceuticals, agriculture, chemicals, and other industries requiring routine moisture analysis.
Features:
XY-MW Series
XY-MW -A Series
The XY-MW Series Halogen Moisture Analyzer determines moisture content by using a halogen heating system to rapidly dry the sample while continuously monitoring its weight with an HBM high-precision sensor. The system automatically calculates moisture percentage, dry residue, and weight loss, providing highly accurate and repeatable results. Users can customize testing through adjustable temperature and time settings, while stored data ensures reliable long-term tracking.
High Accuracy: HBM sensor ensures precise measurements, even for small samples.
Fast Drying: Halogen heating technology speeds up the moisture removal process.
Durable Design: Aluminum shell and stainless steel chamber provide long-lasting stability.
User-Friendly Interface: Choice of standard backlit LCD or advanced HD LCD.
Data Management: Stores up to 15 sets of test data for repeatability.
Flexible Options: USB interface, printer, grinder, and aluminum transport box available.
XY-110MW / XY-105MW – Ideal for educational labs and general quality control.
XY-102MW / XY-100MW – Best for research centers requiring high precision (up to 0.001 g readability).
XY-100MW-A – Recommended for industrial QC departments needing high-definition display and enhanced halogen heating for faster performance.
Food quality laboratories (grain, dairy, meat, bakery products)
Pharmaceutical R&D and production QC
Agricultural product testing (seeds, feed, crops)
Chemical and materials analysis (plastics, textiles, fibers)
Industrial quality assurance departments
Specifications :
| Model | XY-110MW | XY-105MW | XY-102MW | XY-100MW | XY-100MW-A |
| Capacity | 110g | ||||
| Readability | 0.01g | 0.005g | 0.002g | 0.001g | |
| Operating Temp | 5℃-35℃ | ||||
| Display | Backlit LCD | High definition backlit LCD | |||
| Calibration | External calibration | ||||
| Interface | RS232(Standard) USB(Optional) | ||||
| Pan Size | Φ90mm | ||||
| Packing Size | 485340350mm | ||||
| Gross Weight | 6.8kg | ||||
| Heating Unit | Halogen lamp-1 | Halogen lamp-2 | |||
| Temp. Sensor | PT100 | ||||
| Temp. Range | 40℃-199℃ | ||||
| Temp. Step | 1℃ | ||||
| Moisture Range | 0.0%-100.0% | 0.00%-100.00% | |||
| Moisture Readability | 0.2% | 0.10% | 0.04% | 0.01% | |
| Dry Range | 100.00%-0.00% | ||||
| Dry Readability | 0.2% | 0.10% | 0.04% | 0.01% | |
| Temp Setting | 40℃-199℃ By 1℃ Step | ||||
| Time Setting | 1-99min By 10s | ||||
| Number Of Storage | 15 | ||||
| Heate power | 220V ±15% 50Hz / 110V±15% 60Hz / 400W | ||||
| Balance power | Input:220V 50Hz / 110V 60Hz Output:9V | ||||
| Chamber Height | 22mm | ||||
| Model | XY-110MW | XY-105MW | XY-102MW | XY-100MW | XY-100MW-A |
| Capacity | 110g | ||||
| Readability | 0.01g | 0.005g | 0.002g | 0.001g | |
| Operating Temp | 5℃-35℃ | ||||
| Display | Backlit LCD | High definition backlit LCD | |||
| Calibration | External calibration | ||||
| Interface | RS232(Standard) USB(Optional) | ||||
| Pan Size | Φ90mm | ||||
| Packing Size | 485340350mm | ||||
| Gross Weight | 6.8kg | ||||
| Heating Unit | Halogen lamp-1 | Halogen lamp-2 | |||
| Temp. Sensor | PT100 | ||||
| Temp. Range | 40℃-199℃ | ||||
| Temp. Step | 1℃ | ||||
| Moisture Range | 0.0%-100.0% | 0.00%-100.00% | |||
| Moisture Readability | 0.2% | 0.10% | 0.04% | 0.01% | |
| Dry Range | 100.00%-0.00% | ||||
| Dry Readability | 0.2% | 0.10% | 0.04% | 0.01% | |
| Temp Setting | 40℃-199℃ By 1℃ Step | ||||
| Time Setting | 1-99min By 10s | ||||
| Number Of Storage | 15 | ||||
| Heate power | 220V ±15% 50Hz / 110V±15% 60Hz / 400W | ||||
| Balance power | Input:220V 50Hz / 110V 60Hz Output:9V | ||||
| Chamber Height | 22mm | ||||
Download catalog for: