The AELAB GC102AF Gas Chromatograph applies the computer reverse control technology and can conduct remote detection and fault diagnosis, equipped with a flame ionization detector (FID). As a new generation instrument, the GC102AF provides accurate temperature control, strong safety protection, and stable analytical performance for routine and research chromatography.
The GC102AF integrates PC control, precise pneumatic regulation, and a large-capacity oven suitable for packed column installations. Its advanced diagnostic system, automatic ignition, and intelligent heating design ensure stable and reproducible chromatographic operation.
The AELAB GC102AF features a robust, PC-controlled architecture with a high-accuracy temperature system regulating the column oven, sampler, and detector zones. The built-in heating structure delivers fast, uniform thermal distribution with minimal overshoot. A precise single-gas pneumatic control system ensures reproducibility for packed column analysis. The instrument accommodates a 300 mm × 280 mm × 270 mm oven volume, enabling installation of various packed column configurations.
The GC102AF performs gas chromatography separation by controlling column temperature, carrier gas flow, and injection mode. An FID detector quantifies hydrocarbon compounds through flame ionization, offering a detection limit of ≤ 1 × 10⁻¹⁰ g/s and a linear response range ≥ 10⁶. The system displays real-time temperature settings, measured values, and FID amplifier sensitivity, supporting accurate peak acquisition and integration through compatible workstation software.
The GC102AF supports full PC control and integration with the NJ2000 chromatography workstation. Data can be processed, stored, and reviewed through connected software interfaces, ensuring GLP-compliant analytical documentation.
| Model | Specifications |
|---|---|
| GC102AF | FID detection limit ≤ 1 × 10⁻¹⁰ g/s; temperature range 15 °C ~ 399 °C; linear range ≥ 10⁶; oven size 300 × 280 × 270 mm; power ≤ 1500 W; voltage 220 V ± 22 V. |
The AELAB GC102AF is suitable for environmental analysis, petrochemical testing, food safety evaluation, pharmaceutical QC, material studies, and general hydrocarbon quantification. Its high-sensitivity FID detection supports trace hydrocarbon measurement, purity analysis, and routine compositional testing.
The GC102AF is manufactured under AELAB’s quality control protocols and supports GLP-oriented data workflows. Electrical and analytical performance conforms to laboratory safety and operational reliability standards.
Specifications :
| General Features | |
|---|---|
| PC Control | User-friendly interface, easy operation |
| Temperature Control Accuracy | Better than ±0.1 °C |
| Heating Speed | Fast; overshoot temperature is small |
| Safety Functions | Self-diagnosis, power protection, oven over-temperature protection, automatic ignition |
| Display Capability | Temperature settings, actual value, FID amplifier sensitivity |
| Pneumatic Control | Single gas system with precise pneumatic control valve |
| Packed Column Functions | On-column injection, instantaneous vaporization injection, gas injection |
| Workstation Compatibility | Open system; NJ2000 chromatography workstation |
| Oven Capacity | 300 mm × 280 mm × 270 mm |
| Heating Structure | Built-in heating wire |
| Temperature Control | |
| Temperature Areas | Column oven, sampler, detector |
| Temperature Range | 15 °C ~ 399 °C above room temperature (increment: 1 °C) |
| Temperature Accuracy | Better than ±0.1 °C (measured at 200 °C) |
| Flame Ionization Detector (FID) | |
| Detection Limit | Dt ≤ 1 × 10⁻¹⁰ g/s (octane and hexadecane) |
| Baseline Drift | ≤ 2 × 10⁻¹² A/h |
| Linear Range | ≥ 10⁶ |
| Max. Limit Temperature | 400 °C |
| Voltage | 220 V ± 22 V, 50 Hz ± 0.5 Hz |
| Power | ≤ 1500 W |
| Package Size | 945 mm × 655 mm × 750 mm |
| G.W. | ≈ 70 kg |
| Optional Accessories | |
| N2000 Chromatography Workstation | Optional |
| Packed Column | Optional |
| General Features | |
|---|---|
| PC Control | User-friendly interface, easy operation |
| Temperature Control Accuracy | Better than ±0.1 °C |
| Heating Speed | Fast; overshoot temperature is small |
| Safety Functions | Self-diagnosis, power protection, oven over-temperature protection, automatic ignition |
| Display Capability | Temperature settings, actual value, FID amplifier sensitivity |
| Pneumatic Control | Single gas system with precise pneumatic control valve |
| Packed Column Functions | On-column injection, instantaneous vaporization injection, gas injection |
| Workstation Compatibility | Open system; NJ2000 chromatography workstation |
| Oven Capacity | 300 mm × 280 mm × 270 mm |
| Heating Structure | Built-in heating wire |
| Temperature Control | |
| Temperature Areas | Column oven, sampler, detector |
| Temperature Range | 15 °C ~ 399 °C above room temperature (increment: 1 °C) |
| Temperature Accuracy | Better than ±0.1 °C (measured at 200 °C) |
| Flame Ionization Detector (FID) | |
| Detection Limit | Dt ≤ 1 × 10⁻¹⁰ g/s (octane and hexadecane) |
| Baseline Drift | ≤ 2 × 10⁻¹² A/h |
| Linear Range | ≥ 10⁶ |
| Max. Limit Temperature | 400 °C |
| Voltage | 220 V ± 22 V, 50 Hz ± 0.5 Hz |
| Power | ≤ 1500 W |
| Package Size | 945 mm × 655 mm × 750 mm |
| G.W. | ≈ 70 kg |
| Optional Accessories | |
| N2000 Chromatography Workstation | Optional |
| Packed Column | Optional |