AELAB Mini HCL100 Mini Dry Bath – Compact Digital Heating & Cooling System

The AELAB Mini HCL100 Mini Dry Bath Series offers precise temperature control in a compact and portable design. Featuring digital LCD control, user calibration, and optional cooling capability, this series is ideal for rapid and uniform sample heating or cooling. Suitable for molecular biology, clinical diagnostics, and biochemical research applications.

Modles : MiniHCL 100
whatsapp Whatsapp

The AELAB Mini HCL100 Mini Dry Bath is a compact and lightweight laboratory heating and cooling system with precise digital temperature control. Equipped with an LCD display, user calibration, and overheating protection, it ensures high accuracy for sample incubation. The optional cooling function and interchangeable aluminum blocks make it suitable for various lab tube sizes and applications. The Mini HCL100 includes a hot lid to prevent condensation on tube caps, maintaining sample integrity.

 

🔬 How It Works?

  • The Mini Dry Bath utilizes Peltier thermoelectric technology for precise temperature control, enabling both rapid heating and cooling of samples. The LCD controller provides intuitive digital control over temperature and timing. The Mini HCL100 model includes a heated lid that prevents condensation on tube caps during heating, ensuring sample integrity and uniformity across multiple tubes.
  • Each unit features self-calibration, allowing users to fine-tune temperature accuracy for long-term reliability.

 

💡 Advantages

  • Compact & Lightweight Design: Ideal for crowded lab benches and portable use

  • Digital Accuracy: Temperature and time digitally controlled with real-time LCD display

  • Dual Heating and Cooling: Ensures fast transitions and stable performance

  • User Calibration Function: Maintains temperature precision over long-term operation

  • Overheating Protection: Enhances user safety and equipment longevity

  • Interchangeable Aluminum Blocks: Fits multiple tube sizes (0.2 mL to 50 mL)

  • Optional Car Adapter: Enables field use or mobile laboratory operation

  • Quiet, Efficient Operation: Less than 55 dB noise level for lab comfort

 

🔍 Recommended Models by Use Case

  • Mini HCL100: Equipped with a heated lid, ideal for molecular biology, PCR, and condensation-sensitive experiments

  • Mini HC100: Suitable for research and clinical labs requiring both heating and cooling capabilities

  • Mini H100: Perfect for general incubation and enzyme reactions that require only heating

 

🧪 Ideal For

  • Molecular biology and PCR sample preparation

  • Enzyme and nucleic acid denaturation

  • Protein preservation and incubation

  • Clinical diagnostic testing

  • Education, research, and QC laboratories

 

🧱 Block Accessories

Cat.No. Block Type Capacity
18900414 40×0.2 mL 6.4×20
18900415 24×0.5 mL 8.2×28.4
18900416 15×1.5 mL 11.2×31
18900428 15×2 mL 11×31
18900417 6×5 mL 17×31
18900426 4×15 mL 16.4×45
18900427 2×50 mL 29×45

Specifications :

Specifications Mini HCL100 Mini HC100 Mini H100
Display LCD LCD LCD
Temperature Setting Range (°C) 0–100 0–100 25–100
Temperature Range (°C) RT–23~100 RT–23~100 RT+5~100
Temperature Control Accuracy (°C) ±0.5 ±0.5 ±0.5
Temperature Display Accuracy (°C) 0.1 0.1 0.1
Heating Time (25°C→100°C) ≤20 min ≤20 min ≤20 min
Cooling Time (20°C→0°C) ≤25 min ≤25 min
Max. Heating Rate 8°C/min 8°C/min 6.5°C/min
Max. Cooling Rate 3°C/min 3°C/min
Time Setting Range (sec/min) 0–999 0–999 0–999
Program Memory 9 (2 steps each) 9 (2 steps each) 9 (2 steps each)
Temperature Self-Calibration Support Support Support
Error Code Display Support Support Support
Dimension (W×D×H) 110×162×140 mm 110×162×140 mm 110×162×140 mm
Total Weight (kg) ≤1 ≤1 ≤1
Voltage/Frequency 100–240V, 50/60Hz or DC12V Same Same
Power (W) 60 60 60
Operating Temperature (°C) +10~40 +10~40 +10~40
Operating Humidity (%RH) ≤80 ≤80 ≤80
Specifications Mini HCL100 Mini HC100 Mini H100
Display LCD LCD LCD
Temperature Setting Range (°C) 0–100 0–100 25–100
Temperature Range (°C) RT–23~100 RT–23~100 RT+5~100
Temperature Control Accuracy (°C) ±0.5 ±0.5 ±0.5
Temperature Display Accuracy (°C) 0.1 0.1 0.1
Heating Time (25°C→100°C) ≤20 min ≤20 min ≤20 min
Cooling Time (20°C→0°C) ≤25 min ≤25 min
Max. Heating Rate 8°C/min 8°C/min 6.5°C/min
Max. Cooling Rate 3°C/min 3°C/min
Time Setting Range (sec/min) 0–999 0–999 0–999
Program Memory 9 (2 steps each) 9 (2 steps each) 9 (2 steps each)
Temperature Self-Calibration Support Support Support
Error Code Display Support Support Support
Dimension (W×D×H) 110×162×140 mm 110×162×140 mm 110×162×140 mm
Total Weight (kg) ≤1 ≤1 ≤1
Voltage/Frequency 100–240V, 50/60Hz or DC12V Same Same
Power (W) 60 60 60
Operating Temperature (°C) +10~40 +10~40 +10~40
Operating Humidity (%RH) ≤80 ≤80 ≤80

No download files available for this product.

Frequently Asked Questions

1How does the AELAB Mini Dry Bath maintain precise temperature control?
It employs advanced Peltier thermoelectric modules and microprocessor-based regulation for ±0.5°C accuracy and uniform heating.
2What makes the Mini HCL100 unique among Mini Dry Baths?
The hot lid design prevents condensation on tube caps, ensuring consistent reaction volumes and accurate PCR results.
3Can I use different block sizes with this unit?
Yes, interchangeable aluminum blocks are available for various tube capacities (0.2 mL–50 mL).
4Does the device support user calibration?
Yes, the temperature self-calibration function allows users to adjust and verify performance as needed.
5Is cooling available in all models?
The Mini HCL100 and Mini HC100 support both heating and cooling, while the Mini H100 supports heating only.

Request Quote: AELAB Mini HCL100 Mini Dry Bath – Compact Digital Heating & Cooling System