The AELAB DM1224 Hematocrit Centrifuge is a compact, economical, and high-precision centrifuge designed for rapid hematocrit determination and micro-solution separation. With a powerful brushless DC motor, precise speed control, and advanced safety features, it ensures reliable performance for clinical, research, and diagnostic laboratories.
The DM1224 Hematocrit Centrifuge spins capillary tubes at high speed to separate blood components by density. As the sample rotates, red blood cells pack at the bottom, enabling precise measurement of hematocrit (HCT). The brushless DC motor ensures stable rotation, while the LCD controller regulates speed, RCF, and run time for consistent, repeatable results.
The AELAB DM1224 features a durable housing with a compact footprint suited for benchtop clinical environments. The instrument incorporates a high-strength aluminum AC24 rotor supporting 24 capillary tubes. An LCD panel provides digital control of speed, time, and RCF conversion. The brushless DC motor offers maintenance-free operation and extended service life.
The DM1224 performs hematocrit testing by accelerating capillary tubes to speeds up to 12000 rpm. The centrifugal field of 13680 × g packs erythrocytes at the sealed end of the capillary, allowing clear hematocrit percentage quantification. Users select speed, time (10 sec–99 min), or Continuous mode via the LCD interface. A door interlock prevents operation when the lid is open, ensuring operator safety.
The DM1224 supports GLP-style data consistency through digital control of speed, RCF switching, and run-time programming. Parameters can be reviewed directly via the LCD interface. Optional external printers or LIS systems may be added through standard accessory ports depending on laboratory configuration.
| Model | Specifications |
|---|---|
| DM1224 | 500–12000 rpm; 13680 × g; Brushless DC motor; 8.5 kg; 280 × 364 × 213 mm |
| DM1424 | 200–12000 rpm; 13680 × g; Brushless DC motor; 10.5 kg; 280 × 364 × 274 mm |
The AELAB DM1224 is suitable for clinical hematology labs, biochemistry departments, immunology labs, neonatal bilirubin testing, genetic studies, veterinary clinics, micro-solution separation, and DNA/RNA extraction workflows. It supports routine diagnostic hematocrit measurement and educational laboratory training applications.
The DM1224 adheres to CE, ISO, and GLP standards for laboratory centrifugation. Each unit undergoes factory calibration, motor performance verification, and rotor balance testing to ensure consistent, traceable results.

Specifications :
| Specifications | DM1424 | DM1224 |
|---|---|---|
| Speed Range | 200–12000 rpm, increment: 10 rpm | 500–12000 rpm, increment: 100 rpm |
| Max. RCF | 13680 × g | 13680 × g |
| Speed Accuracy | ±20 | ±100 |
| Run Time | 30 sec–99 min / Continuous | 10 sec–99 min / Continuous |
| Motor | Brushless DC motor | Brushless DC motor |
| Display | LCD | LCD |
| Safety Devices | Door interlock, Overspeed detector; Automatic internal diagnosis, Automatic rotor identification | Door interlock |
| Acceleration/Braking Time | 30 s ↑ 30 s ↓ | 40 s ↑ 40 s ↓ |
| Power Requirements | Single-phase, 200V–240V, 50Hz/60Hz, 5A; 100V–120V, 50Hz/60Hz, 5A; 160W | Single-phase, 200V–240V, 50Hz/60Hz, 5A; 380W |
| Dimension (W×D×H) | 280 × 364 × 274 mm | 280 × 364 × 213 mm |
| Weight | 10.5 kg | 8.5 kg |
| Advanced Features | Speed/RCF switch; Short-time run function; Sound-alert function | Speed/RCF switch; Short-time run function; Sound-alert function |
| Rotor Model | Description |
|---|---|
| AC24 – Cat. No.19400047 | DM1424 & DM1224 Max. speed: 12000rpm Max. RCF: 13680 × g Rotor capacity: capillary tubes ×24 Rotor material: High strength aluminum |
| Specifications | DM1424 | DM1224 |
|---|---|---|
| Speed Range | 200–12000 rpm, increment: 10 rpm | 500–12000 rpm, increment: 100 rpm |
| Max. RCF | 13680 × g | 13680 × g |
| Speed Accuracy | ±20 | ±100 |
| Run Time | 30 sec–99 min / Continuous | 10 sec–99 min / Continuous |
| Motor | Brushless DC motor | Brushless DC motor |
| Display | LCD | LCD |
| Safety Devices | Door interlock, Overspeed detector; Automatic internal diagnosis, Automatic rotor identification | Door interlock |
| Acceleration/Braking Time | 30 s ↑ 30 s ↓ | 40 s ↑ 40 s ↓ |
| Power Requirements | Single-phase, 200V–240V, 50Hz/60Hz, 5A; 100V–120V, 50Hz/60Hz, 5A; 160W | Single-phase, 200V–240V, 50Hz/60Hz, 5A; 380W |
| Dimension (W×D×H) | 280 × 364 × 274 mm | 280 × 364 × 213 mm |
| Weight | 10.5 kg | 8.5 kg |
| Advanced Features | Speed/RCF switch; Short-time run function; Sound-alert function | Speed/RCF switch; Short-time run function; Sound-alert function |
| Rotor Model | Description |
|---|---|
| AC24 – Cat. No.19400047 | DM1424 & DM1224 Max. speed: 12000rpm Max. RCF: 13680 × g Rotor capacity: capillary tubes ×24 Rotor material: High strength aluminum |
No download files available for this product.