The AELAB DM0636 Multi-Purpose Low-Speed Centrifuge is engineered for versatile, high-precision sample separation across chemistry, cytology, research, and industrial laboratories. With a working range of 300–6000 rpm, maintenance-free brushless DC motor, and compatibility with extensive swing-out and fixed-angle rotors, the model ensures reliable, high-efficiency workflows. Its automatic rotor identification and 9 stored programs simplify operation and maximize safety.
The DM0636 supports tubes with caps, blood collection tubes, urine tubes, and multiple rotor adapters, offering wide flexibility for routine and advanced centrifugation tasks. Swing-out rotors and adapters accommodate standard tubes up to 100 mL, delivering stable performance at low speed with precise control.
The AELAB DM0636 incorporates a durable, bench-top design with a brushless DC motor that ensures long service life and low maintenance. The frame integrates an LCD control panel, pulse operation, and sealed chamber structure for controlled operation. Rotor systems are available in Stainless Steel or Aluminum construction, depending on type, including SE4-100 swing-out buckets, fixed-angle rotors, microplate carriers, and conical tube adapters.
The DM0636 centrifuge operates by accelerating samples through rotational force up to 4100 ×g, allowing biological, chemical, or particulate components to separate by density. The instrument provides 9 acceleration and 10 deceleration profiles to optimize sedimentation. Automatic rotor identification regulates safe operating limits, while imbalance and overspeed detection maintain precision during continuous or timed runs from 30 seconds to 99 minutes.
The DM0636 provides digital control through an LCD panel with programmable parameters, speed/RCF switching, and procedural memory. Data can be recorded manually for GLP documentation. The system is compatible with external laboratory information management procedures and standard QA traceability workflows.
| Model / Rotor | Specifications |
|---|---|
| SE4-100 Swing Rotor | Max. speed 4000rpm; Max. RCF 2950×g; Holds 3–100 mL tubes; Bucket sets with multiple adapters; Stainless Steel body |
| S2-MP | Max. speed 4000rpm; Max. RCF 2200×g; Micro-plates 384/PCR/Deep-well × 4 plates; Stainless Steel body + Aluminum buckets |
| AS6-50V | Max. speed 6000rpm; Max. RCF 4020×g; 50 mL ×6 or 15 mL ×6; Aluminum body; Biosafe |
| AS12-PCR8 | Max. speed 6000rpm; Max. RCF 4020×g; PCR 8 strips ×12; Aluminum; Biosafe |
| AS18-5V | Max. speed 6000rpm; Max. RCF 4020×g; 5 mL ×18; Stainless Steel + Aluminum buckets; Biosafe |
| AS30-2 | Max. speed 6000rpm; Max. RCF 4020×g; 2 mL ×30; Aluminum; Biosafe |
| A8-50 | Max. speed 5000rpm; Max. RCF 3960×g; 50 mL ×8 or 15 mL ×16; Aluminum + Stainless Steel adapter |
| AS60-2 | Max. speed 6000rpm; Max. RCF 4020×g; 2 mL ×60; Aluminum; Biosafe |
| A30-15 | Max. speed 4500rpm; Max. RCF 3210×g; 15 mL ×30; Aluminum + Stainless Steel adapter |
The AELAB DM0636 centrifuge is optimized for clinical chemistry, cytology and hematology sample preparation, pharmaceutical and industrial QC testing, PCR and ELISA workflows, academic research, environmental analysis, and routine sample separation involving blood collection tubes, conical tubes, microplates, and urine tubes.
The DM0636 adheres to international ISO, CE, and GLP-aligned manufacturing and safety requirements. Each unit undergoes rotor compatibility validation, electrical safety testing, and performance calibration for traceable laboratory compliance.


Specifications :
| Specifications | DM0636 |
|---|---|
| Speed Range | 300–6000 rpm increment:10 rpm |
| Max. RCF | 4100×g |
| Speed accuracy | ±20 rpm |
| Max. Capacity | 100 mL×4 |
| Run Time | 30 sec–99 mins/continuous |
| Motor | Brushless DC motor |
| Display | LCD |
| Program Memory | 9 |
| Safety Devices | Door imbalance protection Over speed & Over temperature detection |
| Acceleration/Deceleration | 9 ↑ / 10 ↓ steps |
| Power Requirements | 400 W, Single-phase AC220V–240V, 50Hz/60Hz, 6.3A; AC110V–120V, 50Hz/60Hz, 10A |
| Noise Level | ≤65 dB |
| Dimension (W×D×H) | 570×445×295 mm |
| Weight | 36 kg |
| Advanced Features | Speed/rcf switch, Rotor identification |
| Specifications | DM0636 |
|---|---|
| Speed Range | 300–6000 rpm increment:10 rpm |
| Max. RCF | 4100×g |
| Speed accuracy | ±20 rpm |
| Max. Capacity | 100 mL×4 |
| Run Time | 30 sec–99 mins/continuous |
| Motor | Brushless DC motor |
| Display | LCD |
| Program Memory | 9 |
| Safety Devices | Door imbalance protection Over speed & Over temperature detection |
| Acceleration/Deceleration | 9 ↑ / 10 ↓ steps |
| Power Requirements | 400 W, Single-phase AC220V–240V, 50Hz/60Hz, 6.3A; AC110V–120V, 50Hz/60Hz, 10A |
| Noise Level | ≤65 dB |
| Dimension (W×D×H) | 570×445×295 mm |
| Weight | 36 kg |
| Advanced Features | Speed/rcf switch, Rotor identification |
No download files available for this product.