The AELAB Benchtop Touch Screen Electrochemistry Meter Series is designed for laboratories requiring high-precision pH, ORP, Conductivity, Salinity, TDS, Resistivity, and DO measurements with a modern, intuitive user interface. The 7-inch touch display simplifies operation while supporting automatic calibration, automatic temperature compensation, data logging, and workflow optimization.
These benchtop meters convert electrochemical signals from dedicated probes into stable and accurate digital readings. With intelligent compensation algorithms, multi-point calibration, and IP54 protection, the AELAB series ensures reliable analytical performance for research laboratories, industrial quality control, and environmental monitoring facilities.
The AELAB series incorporates a high-resolution 7-inch capacitive touch screen, a flexible probe holder, magnetic stirrer (included in most kits), and sealed IP54-grade housing. Stainless-Steel temperature probes, glass pH electrodes, conductivity probes (K=1.0), and polarographic DO probes provide reliable sensing performance. The benchtop platform stabilizes measurements under laboratory conditions and supports durable, long-term operation.
The instruments analyze electrochemical potentials using high-sensitivity probes immersed in liquid samples. pH and ORP signals are measured in mV and converted to corresponding chemical values. Conductivity, Resistivity, Salinity, and TDS are quantified using auto-ranging conductivity cells. Dissolved oxygen measurements use polarographic sensor technology with automatic barometric and temperature compensation. Real-time ATC, multi-point calibration, salinity correction (for DO), and automated compensation ensure accurate results across varying sample conditions.
The series supports Flash disk export, direct PC communication, and optional wireless printer output. Measurement parameters, calibration logs, and stored readings (up to 500 entries per parameter) can be saved for GLP documentation and LIMS integration. USB interfaces enable rapid data transfer for QA/QC reporting.
| Model | Specifications |
|---|---|
| PH100T | Single-parameter pH; (–2.000–20.000)pH; 1–5 point calibration; IP54; Flash disk/PC/Printer |
| EC100T | Single-parameter Conductivity/TDS/Salinity/Resistivity; auto-ranging; 0–200.0mS/cm |
| DO100T | Single-parameter Dissolved Oxygen; 0.00–20.00mg/L; automatic pressure/temperature compensation |
| PC100T | Multiparameter pH + Conductivity |
| P1D100T | Multiparameter pH + DO |
| C1D100T | Multiparameter Conductivity + DO |
| PCD100T | Full multiparameter pH/Cond/ORP/DO; simultaneous display |
The AELAB Benchtop Touch Screen Electrochemistry Meter Series is suitable for environmental monitoring labs, water & wastewater plants, food and beverage QA, chemical production QC, pharmaceutical laboratories, academic teaching labs, and industrial R&D workflows. The wide parameter coverage enables precise analysis of natural waters, process solutions, fermentation media, and laboratory samples.
AELAB instruments follow ISO and GLP principles, providing traceable calibration, stable measurement performance, and fully documented parameter logs. IP54 protection ensures durability in laboratory environments, and factory-tested sensor kits ensure reliable analytical repeatability.
Specifications :
Specifications- Single parameter
| Model | PH100T | EC100T | DO100T | ||
| Parameter | pH/mV.℃ | ✓ | - | - | |
| mV(ORP).℃ | ✓ | - | - | ||
| Cond/TDS/Sal./Res.℃ | - | ✓ | - | ||
| DO.℃ | - | - | ✓ | ||
| pH | Measurement range | (-2.000~20.000)pH | ✓ | - | - |
| Resolution | 0.01/0.001 | ✓ | - | - | |
| Accuracy | ±0.002pH ± one digit | ✓ | - | - | |
| Calibration points | 1, 2, -5 pts automatic | ✓ | - | - | |
| ATC range | (-10.0-135.0)℃/(14.0-275.0)F | ✓ | - | - | |
| ORP | Measurement range | (-1999.9~+1999.9) mV | ✓ | - | - |
| Resolution | 0.1 | ✓ | - | - | |
| Accuracy | ±0.03%F.S ±one digit | ✓ | - | - | |
| Conductivity | Measurement range | 0~2000.0mS/cm, Auto-ranging: 0~19.999μS/cm;20.0~199.9μS/cm;200~1999μS/cm; 2.00~19.99mS/cm; 20.00-199.9mS/cm; 200.0~2000mS/cm(K=10) Match test range: 0~200mS/cm TDS:0~1000.0g/L(TDS factor adjustable) Resistivity:5.000Ω·cm~100.0MΩ·cm Salinity: 0~100ppt |
- | ✓ | - |
| Calibration | one point | - | ✓ | - | |
| Resolution | 0.001 | - | ✓ | - | |
| ATC range | (10.0-135.0)℃/(14.0-275.0)℉ | - | ✓ | - | |
| Accuracy | ±0.5 % F.S ±one digit | - | ✓ | - | |
| DO | Measurement range | (0.00-20.00)mg/L | - | - | ✓ |
| Accuracy | ±0.30 mg/L | - | - | ✓ | |
| DO saturation | (0.0~200.0)% | - | - | ✓ | |
| Automatic barometri pressure compensation |
(0~200.0)kPa | - | - | ✓ | |
| Automatic temperature compensation |
(0.0~50.0)℃/(32.0~122.0)°F | - | - | ✓ | |
| Manual salinity compensation |
0~45ppt | - | - | ✓ | |
| Temperature | Measurement range | (-10.0~135.0)℃/(14.0~275.0)°F | ✓ | ✓ | ✓ |
| Accuracy | ±0.2℃ | ✓ | ✓ | ✓ | |
| Others | Data export | Flash disk/PC/Printer | ✓ | ✓ | ✓ |
| Power supply | DC12V | ✓ | ✓ | ✓ | |
| Test kit | Meter | ✓ | ✓ | ✓ | |
| Glass refillable combination pH probe 201G | ✓ | - | - | ||
| Stainless-steel temperature probe TEMP-01 | ✓ | - | - | ||
| Glass ATC conductivity probe CON201TG,K=1.0 | - | ✓ | - | ||
| Polarographic DO probe DO01-2M | - | - | ✓ | ||
| pH buffer solution:pH4.00/7.00/10.01, 20mL,one for each | ✓ | - | - | ||
| Standard Cond solution:84μS/1413μS/12.88mS/cm,50mL,one for each | - | ✓ | - | ||
| Membrane refill solution:DOS-01, 30mL,1btl | - | - | ✓ | ||
| Membrane sensor caps DOSC:3pcs/group,1pkg | - | - | ✓ | ||
| PC cable:1pc | ✓ | ✓ | ✓ | ||
| Flexible probe holder F01:1pc | ✓ | ✓ | ✓ | ||
| Magnetic stirrer:1pc | ✓ | ✓ | ✓ | ||
| Power adaptor | ✓ | ✓ | ✓ | ||
Specifications-Multiparameter
| Model | PC100T | PD100T | CD100T | PCD100T | ||
| Parameter | pH/mV.℃ | ✓ | ✓ | - | ✓ | |
| mV(ORP).℃ | ✓ | ✓ | - | ✓ | ||
| Cond/TDS/Sal./Res.℃ | ✓ | - | ✓ | ✓ | ||
| DO.℃ | - | ✓ | ✓ | ✓ | ||
| pH | Measurement range | (-2.000~20.000)pH | ✓ | ✓ | - | ✓ |
| Resolution | 0.01/0.001 | ✓ | ✓ | - | ✓ | |
| Accuracy | ±0.002pH ± one digit | ✓ | ✓ | - | ✓ | |
| Calibration points | 1, 2, -5 pts automatic | ✓ | ✓ | - | ✓ | |
| ATC range | (-10.0-135.0)℃/(14.0-275.0)F | ✓ | ✓ | - | ✓ | |
| ORP | Measurement range | (-1999.9~+1999.9) mV | ✓ | ✓ | - | ✓ |
| Resolution | 0.1 | ✓ | ✓ | - | ✓ | |
| Accuracy | ±0.03%F.S ±one digit | ✓ | ✓ | - | ✓ | |
| Conductivity | Measurement range | 0~2000.0mS/cm, Auto-ranging: 0~19.999μS/cm;20.0~199.9μS/cm;200~1999μS/cm; 2.00~19.99mS/cm; 20.00-199.9mS/cm; 200.0~2000mS/cm(K=10) Match test range: 0~200mS/cm TDS:0~1000.0g/L(TDS factor adjustable) Resistivity:5.000Ω·cm~100.0MΩ·cm Salinity: 0~100ppt |
✓ | - | ✓ | ✓ |
| Calibration | one point | ✓ | - | ✓ | ✓ | |
| Resolution | 0.001 | ✓ | - | ✓ | ✓ | |
| ATC range | (0.0~50.0)℃/(32.0~122.0)°F | ✓ | - | ✓ | ✓ | |
| Accuracy | ±0.5 % F.S ±one digit | ✓ | - | ✓ | ✓ | |
| DO | Measurement range | (0.00-20.00)mg/L | - | ✓ | ✓ | ✓ |
| Accuracy | ±0.30 mg/L | - | ✓ | ✓ | ✓ | |
| DO saturation | (0.0~200.0)% | - | ✓ | ✓ | ✓ | |
| Automatic barometri pressure compensation |
(0~200.0)kPa | - | ✓ | ✓ | ✓ | |
| Automatic temperature compensation |
(0.0~50.0)℃/(32.0~122.0)°F | - | ✓ | ✓ | ✓ | |
| Manual salinity compensation |
0~45ppt | - | ✓ | ✓ | ✓ | |
| Temperature | Measurement range | (-10.0~135.0)℃/(14.0~275.0)°F | ✓ | ✓ | ✓ | ✓ |
| Accuracy | ±0.2℃ | ✓ | ✓ | ✓ | ✓ | |
| Others | Data export | Flash disk/PC/Printer | ✓ | ✓ | ✓ | ✓ |
| Power supply | DC12V | ✓ | ✓ | ✓ | ✓ | |
| Test kit | Meter | ✓ | ✓ | ✓ | ✓ | |
| Glass refillable combination pH probe 201G | ✓ | ✓ | - | ✓ | ||
| Stainless-steel temperature probe TEMP-01 | ✓ | ✓ | - | ✓ | ||
| Glass ATC conductivity probe CON201TG,K=1.0 | ✓ | ✓ | ✓ | ✓ | ||
| Polarographic DO probe DO01-2M | - | ✓ | ✓ | ✓ | ||
| pH buffer solution:pH4.00/7.00/10.01, 20mL,one for each | ✓ | ✓ | - | ✓ | ||
| Standard Cond solution:84μS/1413μS/12.88mS/cm,50mL,one for each | ✓ | - | ✓ | ✓ | ||
| Membrane refill solution:DOS-01, 30mL,1btl | - | ✓ | ✓ | ✓ | ||
| Membrane sensor caps DOSC:3pcs/group,1pkg | - | ✓ | ✓ | ✓ | ||
| PC cable:1pc | ✓ | ✓ | ✓ | ✓ | ||
| Flexible probe holder F01:1pc | ✓ | ✓ | ✓ | ✓ | ||
| Magnetic stirrer:1pc | ✓ | ✓ | ✓ | ✓ | ||
| Power adaptor | ✓ | ✓ | ✓ | ✓ | ||
Specifications- Single parameter
| Model | PH100T | EC100T | DO100T | ||
| Parameter | pH/mV.℃ | ✓ | - | - | |
| mV(ORP).℃ | ✓ | - | - | ||
| Cond/TDS/Sal./Res.℃ | - | ✓ | - | ||
| DO.℃ | - | - | ✓ | ||
| pH | Measurement range | (-2.000~20.000)pH | ✓ | - | - |
| Resolution | 0.01/0.001 | ✓ | - | - | |
| Accuracy | ±0.002pH ± one digit | ✓ | - | - | |
| Calibration points | 1, 2, -5 pts automatic | ✓ | - | - | |
| ATC range | (-10.0-135.0)℃/(14.0-275.0)F | ✓ | - | - | |
| ORP | Measurement range | (-1999.9~+1999.9) mV | ✓ | - | - |
| Resolution | 0.1 | ✓ | - | - | |
| Accuracy | ±0.03%F.S ±one digit | ✓ | - | - | |
| Conductivity | Measurement range | 0~2000.0mS/cm, Auto-ranging: 0~19.999μS/cm;20.0~199.9μS/cm;200~1999μS/cm; 2.00~19.99mS/cm; 20.00-199.9mS/cm; 200.0~2000mS/cm(K=10) Match test range: 0~200mS/cm TDS:0~1000.0g/L(TDS factor adjustable) Resistivity:5.000Ω·cm~100.0MΩ·cm Salinity: 0~100ppt |
- | ✓ | - |
| Calibration | one point | - | ✓ | - | |
| Resolution | 0.001 | - | ✓ | - | |
| ATC range | (10.0-135.0)℃/(14.0-275.0)℉ | - | ✓ | - | |
| Accuracy | ±0.5 % F.S ±one digit | - | ✓ | - | |
| DO | Measurement range | (0.00-20.00)mg/L | - | - | ✓ |
| Accuracy | ±0.30 mg/L | - | - | ✓ | |
| DO saturation | (0.0~200.0)% | - | - | ✓ | |
| Automatic barometri pressure compensation |
(0~200.0)kPa | - | - | ✓ | |
| Automatic temperature compensation |
(0.0~50.0)℃/(32.0~122.0)°F | - | - | ✓ | |
| Manual salinity compensation |
0~45ppt | - | - | ✓ | |
| Temperature | Measurement range | (-10.0~135.0)℃/(14.0~275.0)°F | ✓ | ✓ | ✓ |
| Accuracy | ±0.2℃ | ✓ | ✓ | ✓ | |
| Others | Data export | Flash disk/PC/Printer | ✓ | ✓ | ✓ |
| Power supply | DC12V | ✓ | ✓ | ✓ | |
| Test kit | Meter | ✓ | ✓ | ✓ | |
| Glass refillable combination pH probe 201G | ✓ | - | - | ||
| Stainless-steel temperature probe TEMP-01 | ✓ | - | - | ||
| Glass ATC conductivity probe CON201TG,K=1.0 | - | ✓ | - | ||
| Polarographic DO probe DO01-2M | - | - | ✓ | ||
| pH buffer solution:pH4.00/7.00/10.01, 20mL,one for each | ✓ | - | - | ||
| Standard Cond solution:84μS/1413μS/12.88mS/cm,50mL,one for each | - | ✓ | - | ||
| Membrane refill solution:DOS-01, 30mL,1btl | - | - | ✓ | ||
| Membrane sensor caps DOSC:3pcs/group,1pkg | - | - | ✓ | ||
| PC cable:1pc | ✓ | ✓ | ✓ | ||
| Flexible probe holder F01:1pc | ✓ | ✓ | ✓ | ||
| Magnetic stirrer:1pc | ✓ | ✓ | ✓ | ||
| Power adaptor | ✓ | ✓ | ✓ | ||
Specifications-Multiparameter
| Model | PC100T | PD100T | CD100T | PCD100T | ||
| Parameter | pH/mV.℃ | ✓ | ✓ | - | ✓ | |
| mV(ORP).℃ | ✓ | ✓ | - | ✓ | ||
| Cond/TDS/Sal./Res.℃ | ✓ | - | ✓ | ✓ | ||
| DO.℃ | - | ✓ | ✓ | ✓ | ||
| pH | Measurement range | (-2.000~20.000)pH | ✓ | ✓ | - | ✓ |
| Resolution | 0.01/0.001 | ✓ | ✓ | - | ✓ | |
| Accuracy | ±0.002pH ± one digit | ✓ | ✓ | - | ✓ | |
| Calibration points | 1, 2, -5 pts automatic | ✓ | ✓ | - | ✓ | |
| ATC range | (-10.0-135.0)℃/(14.0-275.0)F | ✓ | ✓ | - | ✓ | |
| ORP | Measurement range | (-1999.9~+1999.9) mV | ✓ | ✓ | - | ✓ |
| Resolution | 0.1 | ✓ | ✓ | - | ✓ | |
| Accuracy | ±0.03%F.S ±one digit | ✓ | ✓ | - | ✓ | |
| Conductivity | Measurement range | 0~2000.0mS/cm, Auto-ranging: 0~19.999μS/cm;20.0~199.9μS/cm;200~1999μS/cm; 2.00~19.99mS/cm; 20.00-199.9mS/cm; 200.0~2000mS/cm(K=10) Match test range: 0~200mS/cm TDS:0~1000.0g/L(TDS factor adjustable) Resistivity:5.000Ω·cm~100.0MΩ·cm Salinity: 0~100ppt |
✓ | - | ✓ | ✓ |
| Calibration | one point | ✓ | - | ✓ | ✓ | |
| Resolution | 0.001 | ✓ | - | ✓ | ✓ | |
| ATC range | (0.0~50.0)℃/(32.0~122.0)°F | ✓ | - | ✓ | ✓ | |
| Accuracy | ±0.5 % F.S ±one digit | ✓ | - | ✓ | ✓ | |
| DO | Measurement range | (0.00-20.00)mg/L | - | ✓ | ✓ | ✓ |
| Accuracy | ±0.30 mg/L | - | ✓ | ✓ | ✓ | |
| DO saturation | (0.0~200.0)% | - | ✓ | ✓ | ✓ | |
| Automatic barometri pressure compensation |
(0~200.0)kPa | - | ✓ | ✓ | ✓ | |
| Automatic temperature compensation |
(0.0~50.0)℃/(32.0~122.0)°F | - | ✓ | ✓ | ✓ | |
| Manual salinity compensation |
0~45ppt | - | ✓ | ✓ | ✓ | |
| Temperature | Measurement range | (-10.0~135.0)℃/(14.0~275.0)°F | ✓ | ✓ | ✓ | ✓ |
| Accuracy | ±0.2℃ | ✓ | ✓ | ✓ | ✓ | |
| Others | Data export | Flash disk/PC/Printer | ✓ | ✓ | ✓ | ✓ |
| Power supply | DC12V | ✓ | ✓ | ✓ | ✓ | |
| Test kit | Meter | ✓ | ✓ | ✓ | ✓ | |
| Glass refillable combination pH probe 201G | ✓ | ✓ | - | ✓ | ||
| Stainless-steel temperature probe TEMP-01 | ✓ | ✓ | - | ✓ | ||
| Glass ATC conductivity probe CON201TG,K=1.0 | ✓ | ✓ | ✓ | ✓ | ||
| Polarographic DO probe DO01-2M | - | ✓ | ✓ | ✓ | ||
| pH buffer solution:pH4.00/7.00/10.01, 20mL,one for each | ✓ | ✓ | - | ✓ | ||
| Standard Cond solution:84μS/1413μS/12.88mS/cm,50mL,one for each | ✓ | - | ✓ | ✓ | ||
| Membrane refill solution:DOS-01, 30mL,1btl | - | ✓ | ✓ | ✓ | ||
| Membrane sensor caps DOSC:3pcs/group,1pkg | - | ✓ | ✓ | ✓ | ||
| PC cable:1pc | ✓ | ✓ | ✓ | ✓ | ||
| Flexible probe holder F01:1pc | ✓ | ✓ | ✓ | ✓ | ||
| Magnetic stirrer:1pc | ✓ | ✓ | ✓ | ✓ | ||
| Power adaptor | ✓ | ✓ | ✓ | ✓ | ||
No download files available for this product.