The AELAB Benchtop-Classical Series provides high-accuracy electrochemical measurement solutions including pH, ORP, conductivity, TDS, salinity, resistivity, and dissolved oxygen. Engineered for modern laboratory workflows, the series integrates a high-resolution 7″ display, automatic calibration, and multi-mode measurement capability for reliable analytical performance.
Designed for professional research, environmental testing, industrial QC, and academic laboratories, the AELAB Benchtop-Classical Series stabilizes and displays electrochemical readings with automatic temperature compensation and robust data storage, supporting consistent and traceable scientific measurement.
The system incorporates a 7″ high-resolution display with white backlight, a flexible probe holder, and a durable IP54-rated housing suitable for laboratory environments. Each model integrates specialized sensors—pH glass electrodes, ORP electrodes, conductivity cells, or polarographic DO probes—depending on the measurement parameters. The design supports rapid electrode replacement, stable measurement indication, and direct access to calibration functions.
The AELAB Benchtop-Classical Series converts electrochemical activity in aqueous samples into electrical signals corresponding to pH, mV, conductivity, TDS, salinity, resistivity, or dissolved oxygen. The instrument processes these signals using internal reference algorithms, applies automatic temperature compensation within specified ATC ranges, and displays stabilized readings. DO measurement integrates barometric pressure and salinity compensation for accurate dissolved oxygen quantification.
The Benchtop-Classical Series supports USB flash disk data export and optional wireless printing. Stored measurement data can be transferred to PCs for reporting, audit trails, or GLP-compliant archiving. The system uses a DC12V power supply suitable for benchtop workstations and controlled lab environments.
| Model | Specifications |
|---|---|
| PH100 | pH/ORP measurement, (-2.00–20.00)pH, 7″ display, IP54 protection |
| EC100 | Conductivity/TDS/Salinity/Resistivity analysis, full auto-ranging conductivity |
| DO100 | Dissolved oxygen measurement, 0.00–20.00mg/L, DO saturation 0–200% |
| PC100 | pH + ORP + Conductivity multiparameter measurement |
| PD100 | pH + ORP + DO multiparameter measurement |
| CD100 | Conductivity + DO combined analysis |
| PCD100 | Full multiparameter: pH/ORP/Conductivity/DO analysis |
The AELAB Benchtop-Classical Series is suited to food and beverage quality control, environmental water analysis, wastewater treatment monitoring, chemical laboratory QC, academic studies, aquaculture management, and hydroponic solution monitoring. The multi-parameter models offer extended capability for research institutions requiring broad electrochemical measurement coverage.
AELAB instruments comply with laboratory quality system requirements and support traceable calibration through standardized buffer and conductivity solutions. IP54 ingress protection, stable electronics, and controlled calibration workflows ensure consistent measurement performance aligned with GLP and ISO laboratory practices.
Specifications :
Specifications-Single parameter
| Model | PH100T | EC100T | DO100T | ||
| Parameter | pH/mV.℃ | ✓ | - | - | |
| mV(ORP).℃ | ✓ | - | - | ||
| Cond/TDS/Sal./Res.℃ | - | ✓ | - | ||
| DO.℃ | - | - | ✓ | ||
| pH | Measurement range | (-2.00~20.00)pH | ✓ | - | - |
| Resolution | 0.1/0.01 | ✓ | - | - | |
| Accuracy | ±0.01pH ± one digit | ✓ | - | - | |
| Calibration points | 1, 2, -3 pts automatic | ✓ | - | - | |
| ATC range | (-9.9-130.0)℃/(14.18-266.0)F | ✓ | - | - | |
| ORP | Measurement range | (-1999.9~+1999.9) mV | ✓ | - | - |
| Resolution | 1 | ✓ | - | - | |
| Accuracy | ±0.01%F.S ±one digit | ✓ | - | - | |
| Conductivity | Measurement range | 0~200.0mS/cm, Auto-ranging: 0~19.99μS/cm;20.0~199.9μS/cm;200~1999μS/cm; 2.00~19.99mS/cm; 20.00-199.9mS/cm; TDS:0~100.0g/L Resistivity:5.00Ω·cm~100.0MΩ·cm Salinity:0~100ppt |
- | ✓ | - |
| Calibration | one point | - | ✓ | - | |
| Resolution | 0.001 | - | ✓ | - | |
| ATC range | (0.0-50.0)℃/(32.0-122.0)℉ | - | ✓ | - | |
| Accuracy | ±1.0 % F.S ±one digit | - | ✓ | - | |
| DO | Measurement range | (0.00-20.00)mg/L | - | - | ✓ |
| Accuracy | ±0.30 mg/L | - | - | ✓ | |
| DO saturation | (0.0~200.0)% | - | - | ✓ | |
| Automatic barometri pressure compensation |
(0~200.0)kPa | - | - | ✓ | |
| Automatic temperature compensation |
(0.0~50.0)℃/(32.0~122.0)°F | - | - | ✓ | |
| Manual salinity compensation |
0~45ppt | - | - | ✓ | |
| Temperature | Measurement range | (-9.9~130.0)℃/(14.18~266.0)°F | ✓ | ✓ | ✓ |
| Accuracy | ±0.2℃ | ✓ | ✓ | ✓ | |
| Others | Data export | Flash disk/PC/Printer | ✓ | ✓ | ✓ |
| Power supply | DC12V | ✓ | ✓ | ✓ | |
| Test kit | Meter | ✓ | ✓ | ✓ | |
| Plastic ATC pH probe 201T | ✓ | - | - | ||
| Glass ATC conductivity probe CON201TG,K=1.0 | - | ✓ | - | ||
| Polarographic DO probe DO01-2M,cable length:2m | - | - | ✓ | ||
| pH buffer solution:pH4.00/7.00/10.01, 50mL,one for each | ✓ | - | - | ||
| Standard Cond solution:84μS/1413μS/12.88mS/cm,50mL,one for each | - | ✓ | - | ||
| Membrane refill solution:DOS-01, 30mL,1btl | - | - | ✓ | ||
| Membrane sensor caps DOSC:3pcs/group,1pkg | - | - | ✓ | ||
| Power adaptor:1pc | ✓ | ✓ | ✓ | ||
| Flexible probe holder F01:1pc | ✓ | ✓ | ✓ | ||
Specifications-Multiparameter
| Model | PC100T | PD100T | CD100T | PCD100T | ||
| Parameter | pH/mV.℃ | ✓ | ✓ | - | ✓ | |
| mV(ORP).℃ | ✓ | ✓ | - | ✓ | ||
| Cond/TDS/Sal./Res.℃ | ✓ | - | ✓ | ✓ | ||
| DO.℃ | - | ✓ | ✓ | ✓ | ||
| pH | Measurement range | (-2.00~20.00)pH | ✓ | ✓ | - | ✓ |
| Resolution | 0.1/0.01 | ✓ | ✓ | - | ✓ | |
| Accuracy | ±0.01pH ± one digit | ✓ | ✓ | - | ✓ | |
| Calibration points | 1, 2, -3 pts automatic | ✓ | ✓ | - | ✓ | |
| ATC range | (-9.9-130.0)℃/(14.18-266.0)F | ✓ | ✓ | - | ✓ | |
| ORP | Measurement range | (-1999.9~+1999.9) mV | ✓ | ✓ | - | ✓ |
| Resolution | 1 | ✓ | ✓ | - | ✓ | |
| Accuracy | ±0.01%F.S ±one digit | ✓ | ✓ | - | ✓ | |
| Conductivity | Measurement range | 0~200.0mS/cm, Auto-ranging: 0~19.99μS/cm;20.0~199.9μS/cm;200~1999μS/cm; 2.00~19.99mS/cm; 20.00-199.9mS/cm; TDS:0~100.0g/L Resistivity:5.00Ω·cm~100.0MΩ·cm Salinity:0~100ppt |
✓ | - | ✓ | ✓ |
| Calibration | one point | ✓ | - | ✓ | ✓ | |
| Resolution | 0.001 | ✓ | - | ✓ | ✓ | |
| ATC range | (0.0-50.0)℃/(32.0-122.0)℉ | ✓ | - | ✓ | ✓ | |
| Accuracy | ±1.0 % F.S ±one digit | ✓ | - | ✓ | ✓ | |
| DO | Measurement range | (0.00-20.00)mg/L | - | ✓ | ✓ | ✓ |
| Accuracy | ±0.30 mg/L | - | ✓ | ✓ | ✓ | |
| DO saturation | (0.0~200.0)% | - | ✓ | ✓ | ✓ | |
| Automatic barometri pressure compensation |
(0~200.0)kPa | - | ✓ | ✓ | ✓ | |
| Automatic temperature compensation |
(0.0~50.0)℃/(32.0~122.0)°F | - | ✓ | ✓ | ✓ | |
| Manual salinity compensation |
0~45ppt | - | ✓ | ✓ | ✓ | |
| Temperature | Measurement range | (-9.9~130.0)℃/(14.18~266.0)°F | ✓ | ✓ | ✓ | ✓ |
| Accuracy | ±0.2℃ | ✓ | ✓ | ✓ | ✓ | |
| Others | Data export | Flash disk/PC/Printer | ✓ | ✓ | ✓ | ✓ |
| Power supply | DC12V | ✓ | ✓ | ✓ | ✓ | |
| Test kit | Meter | ✓ | ✓ | ✓ | ✓ | |
| Plastic ATC pH probe 201T | ✓ | ✓ | ✓ | |||
| Glass ATC conductivity probe CON201TG,K=1.0 | ✓ | - | ✓ | ✓ | ||
| Polarographic DO probe DO01-2M,cable length:2m | - | ✓ | ✓ | ✓ | ||
| pH buffer solution:pH4.00/7.00/10.01, 50mL,one for each | ✓ | ✓ | ✓ | |||
| Standard Cond solution:84μS/1413μS/12.88mS/cm,50mL,one for each | ✓ | - | ✓ | ✓ | ||
| Membrane refill solution:DOS-01, 30mL,1btl | - | ✓ | ✓ | ✓ | ||
| Membrane sensor caps DOSC:3pcs/group,1pkg | - | ✓ | ✓ | ✓ | ||
| Power adaptor | ✓ | ✓ | ✓ | ✓ | ||
| Flexible probe holder F01:1pc | ✓ | ✓ | ✓ | ✓ | ||
Specifications-Single parameter
| Model | PH100T | EC100T | DO100T | ||
| Parameter | pH/mV.℃ | ✓ | - | - | |
| mV(ORP).℃ | ✓ | - | - | ||
| Cond/TDS/Sal./Res.℃ | - | ✓ | - | ||
| DO.℃ | - | - | ✓ | ||
| pH | Measurement range | (-2.00~20.00)pH | ✓ | - | - |
| Resolution | 0.1/0.01 | ✓ | - | - | |
| Accuracy | ±0.01pH ± one digit | ✓ | - | - | |
| Calibration points | 1, 2, -3 pts automatic | ✓ | - | - | |
| ATC range | (-9.9-130.0)℃/(14.18-266.0)F | ✓ | - | - | |
| ORP | Measurement range | (-1999.9~+1999.9) mV | ✓ | - | - |
| Resolution | 1 | ✓ | - | - | |
| Accuracy | ±0.01%F.S ±one digit | ✓ | - | - | |
| Conductivity | Measurement range | 0~200.0mS/cm, Auto-ranging: 0~19.99μS/cm;20.0~199.9μS/cm;200~1999μS/cm; 2.00~19.99mS/cm; 20.00-199.9mS/cm; TDS:0~100.0g/L Resistivity:5.00Ω·cm~100.0MΩ·cm Salinity:0~100ppt |
- | ✓ | - |
| Calibration | one point | - | ✓ | - | |
| Resolution | 0.001 | - | ✓ | - | |
| ATC range | (0.0-50.0)℃/(32.0-122.0)℉ | - | ✓ | - | |
| Accuracy | ±1.0 % F.S ±one digit | - | ✓ | - | |
| DO | Measurement range | (0.00-20.00)mg/L | - | - | ✓ |
| Accuracy | ±0.30 mg/L | - | - | ✓ | |
| DO saturation | (0.0~200.0)% | - | - | ✓ | |
| Automatic barometri pressure compensation |
(0~200.0)kPa | - | - | ✓ | |
| Automatic temperature compensation |
(0.0~50.0)℃/(32.0~122.0)°F | - | - | ✓ | |
| Manual salinity compensation |
0~45ppt | - | - | ✓ | |
| Temperature | Measurement range | (-9.9~130.0)℃/(14.18~266.0)°F | ✓ | ✓ | ✓ |
| Accuracy | ±0.2℃ | ✓ | ✓ | ✓ | |
| Others | Data export | Flash disk/PC/Printer | ✓ | ✓ | ✓ |
| Power supply | DC12V | ✓ | ✓ | ✓ | |
| Test kit | Meter | ✓ | ✓ | ✓ | |
| Plastic ATC pH probe 201T | ✓ | - | - | ||
| Glass ATC conductivity probe CON201TG,K=1.0 | - | ✓ | - | ||
| Polarographic DO probe DO01-2M,cable length:2m | - | - | ✓ | ||
| pH buffer solution:pH4.00/7.00/10.01, 50mL,one for each | ✓ | - | - | ||
| Standard Cond solution:84μS/1413μS/12.88mS/cm,50mL,one for each | - | ✓ | - | ||
| Membrane refill solution:DOS-01, 30mL,1btl | - | - | ✓ | ||
| Membrane sensor caps DOSC:3pcs/group,1pkg | - | - | ✓ | ||
| Power adaptor:1pc | ✓ | ✓ | ✓ | ||
| Flexible probe holder F01:1pc | ✓ | ✓ | ✓ | ||
Specifications-Multiparameter
| Model | PC100T | PD100T | CD100T | PCD100T | ||
| Parameter | pH/mV.℃ | ✓ | ✓ | - | ✓ | |
| mV(ORP).℃ | ✓ | ✓ | - | ✓ | ||
| Cond/TDS/Sal./Res.℃ | ✓ | - | ✓ | ✓ | ||
| DO.℃ | - | ✓ | ✓ | ✓ | ||
| pH | Measurement range | (-2.00~20.00)pH | ✓ | ✓ | - | ✓ |
| Resolution | 0.1/0.01 | ✓ | ✓ | - | ✓ | |
| Accuracy | ±0.01pH ± one digit | ✓ | ✓ | - | ✓ | |
| Calibration points | 1, 2, -3 pts automatic | ✓ | ✓ | - | ✓ | |
| ATC range | (-9.9-130.0)℃/(14.18-266.0)F | ✓ | ✓ | - | ✓ | |
| ORP | Measurement range | (-1999.9~+1999.9) mV | ✓ | ✓ | - | ✓ |
| Resolution | 1 | ✓ | ✓ | - | ✓ | |
| Accuracy | ±0.01%F.S ±one digit | ✓ | ✓ | - | ✓ | |
| Conductivity | Measurement range | 0~200.0mS/cm, Auto-ranging: 0~19.99μS/cm;20.0~199.9μS/cm;200~1999μS/cm; 2.00~19.99mS/cm; 20.00-199.9mS/cm; TDS:0~100.0g/L Resistivity:5.00Ω·cm~100.0MΩ·cm Salinity:0~100ppt |
✓ | - | ✓ | ✓ |
| Calibration | one point | ✓ | - | ✓ | ✓ | |
| Resolution | 0.001 | ✓ | - | ✓ | ✓ | |
| ATC range | (0.0-50.0)℃/(32.0-122.0)℉ | ✓ | - | ✓ | ✓ | |
| Accuracy | ±1.0 % F.S ±one digit | ✓ | - | ✓ | ✓ | |
| DO | Measurement range | (0.00-20.00)mg/L | - | ✓ | ✓ | ✓ |
| Accuracy | ±0.30 mg/L | - | ✓ | ✓ | ✓ | |
| DO saturation | (0.0~200.0)% | - | ✓ | ✓ | ✓ | |
| Automatic barometri pressure compensation |
(0~200.0)kPa | - | ✓ | ✓ | ✓ | |
| Automatic temperature compensation |
(0.0~50.0)℃/(32.0~122.0)°F | - | ✓ | ✓ | ✓ | |
| Manual salinity compensation |
0~45ppt | - | ✓ | ✓ | ✓ | |
| Temperature | Measurement range | (-9.9~130.0)℃/(14.18~266.0)°F | ✓ | ✓ | ✓ | ✓ |
| Accuracy | ±0.2℃ | ✓ | ✓ | ✓ | ✓ | |
| Others | Data export | Flash disk/PC/Printer | ✓ | ✓ | ✓ | ✓ |
| Power supply | DC12V | ✓ | ✓ | ✓ | ✓ | |
| Test kit | Meter | ✓ | ✓ | ✓ | ✓ | |
| Plastic ATC pH probe 201T | ✓ | ✓ | ✓ | |||
| Glass ATC conductivity probe CON201TG,K=1.0 | ✓ | - | ✓ | ✓ | ||
| Polarographic DO probe DO01-2M,cable length:2m | - | ✓ | ✓ | ✓ | ||
| pH buffer solution:pH4.00/7.00/10.01, 50mL,one for each | ✓ | ✓ | ✓ | |||
| Standard Cond solution:84μS/1413μS/12.88mS/cm,50mL,one for each | ✓ | - | ✓ | ✓ | ||
| Membrane refill solution:DOS-01, 30mL,1btl | - | ✓ | ✓ | ✓ | ||
| Membrane sensor caps DOSC:3pcs/group,1pkg | - | ✓ | ✓ | ✓ | ||
| Power adaptor | ✓ | ✓ | ✓ | ✓ | ||
| Flexible probe holder F01:1pc | ✓ | ✓ | ✓ | ✓ | ||
No download files available for this product.