AELAB AE-SP4000 Series Double-Beam UV-Visible Spectrophotometer for High-Accuracy Optical Measurement

The AELAB AE-SP4000 Series Double-Beam UV-Visible Spectrophotometer performs high-accuracy absorbance, transmittance, and concentration analysis for laboratory and industrial quality control. The AE-SP4000 integrates a high-resolution C-T structure monochromator, ARM signal processing, and a 7LCD touch panel for stable optical measurement, GLP verification, and reproducible UV-Visible testing across 190–1100 nm.
Modles : AE-SP4000 (UV) , AE-SP4000 (VIS)
whatsapp Whatsapp

The AELAB AE-SP4000 Series Double-Beam UV-Visible Spectrophotometer is engineered for high-stability optical measurement, supporting absorbance, transmittance, reflectance, and energy testing for laboratory analysis and industrial quality control. The AE-SP4000 uses ARM microcomputer control with advanced signal processing to maintain reproducibility, data integrity, and reliable UV-Visible spectrophotometry.

The AELAB AE-SP4000 double-beam UV-Visible spectrophotometer integrates USB data export, Bluetooth functionality, and CSV reporting to support GLP-aligned documentation. With a high-resolution C-T structure monochromator and a precision optical platform, the AE-SP4000 stabilizes wavelength accuracy, reduces drift, and improves long-term measurement consistency.

 

⚙️ Design & Construction

The AELAB AE-SP4000 Series is built on an integrated aviation-grade aluminum alloy baseplate with a precision-machined mirror holder to ensure long-term optical stability. The AE-SP4000 incorporates a high-resolution C-T structure monochromator and a 1200 line/mm grating optical system for stable wavelength dispersion and reproducible UV-Visible analysis. Independently designed lamp replacement windows with flange-style positioning support controlled maintenance of the Deuterium lamp and Tungsten lamp.

 

🔬 Working Principle / Testing Method

The AELAB AE-SP4000 UV-Visible spectrophotometer quantifies sample absorbance and transmittance by selecting a defined wavelength within 190–1100 nm and measuring optical attenuation through the sample. Instrument electronics process photodetector signals to calculate Abs, %T, concentration factors, and spectral outputs. In scanning modes, the AE-SP4000 measures optical responses at defined intervals to generate spectra, identify peaks and valleys, and store traceable analytical results.

 

💡 Key Advantages

  • The AELAB AE-SP4000 Series provides Wavelength Accuracy ±0.3 nm and Wavelength Repeatability ≤0.1 nm for stable UV-Visible spectrophotometry.
  • Transmittance Accuracy ≤0.1%T and Stray Light ≤0.05%T support high-sensitivity optical measurement.
  • Noise control specified as 0%≤0.05 and 100%≤0.1 supports reproducible baseline evaluation.
  • Baseline Fitness ±0.001 Abs and Draft ≤0.001 Abs support long-term measurement stability.
  • 7LCD with touch panel interface supports guided operation and reduced user error during laboratory testing.
  • 10–50 mm adjustable sample holder accommodates multiple cuvette path lengths for varied testing requirements.
  • Large internal memory stores extensive test data for traceable laboratory records.

 

🔗 Connectivity & Integration

The AELAB AE-SP4000 Series supports U Disk export, Bluetooth data output, and upload to PC by USB port. Data are stored in CSV format for compatibility with laboratory reporting workflows and external analysis tools. Software supports one-click upgrades and Bluetooth printing options as described in the AE-SP4000 feature set.

 

🧠 Model Insight

Model Wavelength Range (nm) Key Optical Components Weight (kg)
AE-SP4000 (UV) 320–1100 Tungsten lamp & Deuterium lamp; 1200 line/mm grating 11
AE-SP4000 (VIS) 190–1100 Tungsten lamp & Deuterium lamp; 1200 line/mm grating 12

 

🧪 Testing Applications

The AELAB AE-SP4000 Series UV-Visible spectrophotometer supports quantitative and qualitative optical analysis for environmental testing, pharmaceutical quality control, food and beverage analysis, biochemical research, clinical and diagnostic workflows, and industrial materials testing. The AE-SP4000 performs absorbance-based concentration measurement, UV-Visible spectrum scanning for compound identification, kinetic time measurement for reaction monitoring, and DNA/protein measurement at 260 nm / 280 nm / 230 nm / 320 nm as defined by the instrument functions.

 

Compliance & Quality Assurance

The AELAB AE-SP4000 Series supports GLP General Laboratory Practice verification functions for wavelength accuracy, photometric accuracy, and stray light validation. Validation results can be stored, exported, and printed to support laboratory audit trails. Manufacturing is described with 32 key quality control points to ensure robustness and unit-to-unit durability for UV-Visible spectrophotometer operation.

Discover precision UV-Visible optical measurement with AELAB AE-SP4000 — engineered for stable absorbance analysis, validated performance control, and traceable laboratory data output.

Specifications :

Technical Specifications – AELAB AE-SP4000 Series
Mode AE-SP4000 (UV) AE-SP4000 (VIS)
Optical System Single beam; with 1200 line/mm grating
Wavelength Range (nm) 320–1100 190–1100
Spectral Bandwidth (nm) 2.0
Wavelength Accuracy (nm) ±0.3
Wavelength Repeatability (nm) ≤0.1
Transmittance Accuracy (%T) ≤0.1
Stray Light (%T) ≤0.05 @360 nm ≤0.05 @220 nm @360 nm
Noise (%T) 0%≤0.05; 100%≤0.1
Draft (Abs) ≤0.001
Baseline Fitness (Abs) ±0.001
Spectral Range 0–200%T, −3.010–3 A, 0–9999C (0–9999F)
Test Mode Abs Trans Reflectance Energy
Light Source Tungsten lamp & Deuterium lamp
Monitor 7LCD with touch panel
Language Chinese、English、Russia、Spanish
Data Output U Disk、Bluetooth、Upload to PC by USB port
Data Format CSV
Sample Holder 10–50 mm adjustable
Power Supply AC 90–250 V / 50–60 Hz
Size (L×W×H) mm 470×330×210
Weight (kg) 11 12
Technical Specifications – AELAB AE-SP4000 Series
Mode AE-SP4000 (UV) AE-SP4000 (VIS)
Optical System Single beam; with 1200 line/mm grating
Wavelength Range (nm) 320–1100 190–1100
Spectral Bandwidth (nm) 2.0
Wavelength Accuracy (nm) ±0.3
Wavelength Repeatability (nm) ≤0.1
Transmittance Accuracy (%T) ≤0.1
Stray Light (%T) ≤0.05 @360 nm ≤0.05 @220 nm @360 nm
Noise (%T) 0%≤0.05; 100%≤0.1
Draft (Abs) ≤0.001
Baseline Fitness (Abs) ±0.001
Spectral Range 0–200%T, −3.010–3 A, 0–9999C (0–9999F)
Test Mode Abs Trans Reflectance Energy
Light Source Tungsten lamp & Deuterium lamp
Monitor 7LCD with touch panel
Language Chinese、English、Russia、Spanish
Data Output U Disk、Bluetooth、Upload to PC by USB port
Data Format CSV
Sample Holder 10–50 mm adjustable
Power Supply AC 90–250 V / 50–60 Hz
Size (L×W×H) mm 470×330×210
Weight (kg) 11 12

No download files available for this product.

Frequently Asked Questions

1What does the AELAB AE-SP4000 Series measure?
The AELAB AE-SP4000 Series UV-Visible spectrophotometer measures absorbance, transmittance, reflectance, and energy for laboratory optical analysis.
2What is the wavelength range of the AE-SP4000?
The specification lists wavelength coverage within 190–1100 nm, with model columns showing 320–1100 and 190–1100 depending on variant.
3Does the AE-SP4000 support GLP verification testing?
Yes. The AE-SP4000 supports GLP verification for wavelength accuracy, photometric accuracy, and stray light, with results that can be stored, exported, and printed.
4How can AE-SP4000 data be exported?
Data output is supported via U Disk, Bluetooth, and upload to PC by USB port, with CSV data format.
5What sample holder range is supported by the AE-SP4000?
The AE-SP4000 sample holder is specified as 10–50 mm adjustable to accommodate different path length requirements.

Request Quote: AELAB AE-SP4000 Series Double-Beam UV-Visible Spectrophotometer for High-Accuracy Optical Measurement