The AELAB DD4-TM / TDL-420 / DL4-TM full automatic uncap centrifuge is engineered for clinical laboratories requiring synchronized blood separation and automated vacuum tube uncapping. Designed for hospital diagnostics, blood stations, radio-immunoassay, and nuclear medicine testing, the centrifuge enhances workflow efficiency while reducing manual handling risks.
By integrating microprocessor regulation, AC frequency motor control, and multi-rotor adaptability, the AELAB automatic uncap centrifuge ensures stable rotational performance, consistent centrifugal force, and reliable sample integrity during high-volume operation.
The AELAB DD4-TM / TDL-420 / DL4-TM centrifuge utilizes a reinforced cabinet structure with integrated vibration damping. The patented layered bucket rotor design supports simultaneous use of 2 ml, 5 ml, and 7 ml vacuum blood tubes while preventing cap drop during high-speed operation.
The AELAB full automatic uncap centrifuge applies controlled centrifugal force to separate blood components while simultaneously executing mechanical uncapping. Microprocessor logic regulates rotational speed, time, and braking to prevent remixing and maintain separation stability.
The AELAB DD4-TM / TDL-420 / DL4-TM centrifuge features integrated LCD or touch LCD control panels for standalone operation. Internal control architecture supports error monitoring and operational status display for GLP-aligned laboratory workflows.
| Model | Temperature Control | Max RCF | Weight |
|---|---|---|---|
| DD4-TM | Room Temperature | 5200 × g | 140 kg |
| TDL-420 | +15 °C ~ +25 °C | 5200 × g | 170 kg |
| DL4-TM | -20 °C ~ +40 °C | 5200 × g | 180 kg |
The AELAB full automatic uncap centrifuge is used for clinical blood separation, serum and plasma preparation, radio-immunoassay workflows, nuclear medicine diagnostics, and high-throughput laboratory sample processing.
The AELAB DD4-TM / TDL-420 / DL4-TM centrifuge is designed for laboratory quality systems aligned with ISO and GLP operational principles. Each unit undergoes functional inspection, motor calibration verification, and safety testing prior to release.

Specifications :
| Model | DD4-TM (LCD) iDD4-TM (Touch LCD) |
TDL-420 (LCD) iTDL-420 (Touch LCD) |
DL4-TM (LCD) iDL4-TM (Touch LCD) |
|---|---|---|---|
| Temperature Range | Room Temperature | +15 °C ~ +25 °C | -20 °C ~ +40 °C |
| NO.1 Angle Rotor | Capacity 12 × 10/15 ml · Max Speed 5000 r/min · RCF 5200 × g | ||
| NO.2 Swing Rotor | Capacity 108 × 2/5 ml · Max Speed 4000 r/min · RCF 3600 × g | ||
| NO.3 Swing Rotor | Capacity 120 × 2/5 ml · Max Speed 4000 r/min · RCF 3680 × g | ||
| NO.4 Swing Rotor | Capacity 162 × 2/5 ml · Max Speed 4000 r/min · RCF 3850 × g | ||
| Motor | Microprocessor Control, AC Frequency Motor | ||
| Timer Range | 0~99 min | ||
| Noise | ≤65dB(A) | ||
| Power Supply | AC 220V & 110V · 50–60Hz · 15A | ||
| Dimensions (L × W × H) | 800 × 610 × 790 mm | ||
| Weight | 140 kg | 170 kg | 180 kg |
| Model | DD4-TM (LCD) iDD4-TM (Touch LCD) |
TDL-420 (LCD) iTDL-420 (Touch LCD) |
DL4-TM (LCD) iDL4-TM (Touch LCD) |
|---|---|---|---|
| Temperature Range | Room Temperature | +15 °C ~ +25 °C | -20 °C ~ +40 °C |
| NO.1 Angle Rotor | Capacity 12 × 10/15 ml · Max Speed 5000 r/min · RCF 5200 × g | ||
| NO.2 Swing Rotor | Capacity 108 × 2/5 ml · Max Speed 4000 r/min · RCF 3600 × g | ||
| NO.3 Swing Rotor | Capacity 120 × 2/5 ml · Max Speed 4000 r/min · RCF 3680 × g | ||
| NO.4 Swing Rotor | Capacity 162 × 2/5 ml · Max Speed 4000 r/min · RCF 3850 × g | ||
| Motor | Microprocessor Control, AC Frequency Motor | ||
| Timer Range | 0~99 min | ||
| Noise | ≤65dB(A) | ||
| Power Supply | AC 220V & 110V · 50–60Hz · 15A | ||
| Dimensions (L × W × H) | 800 × 610 × 790 mm | ||
| Weight | 140 kg | 170 kg | 180 kg |
No download files available for this product.