| Parameter |
LVDV-1T |
LVDV-2T |
| model |
LVDV-1T |
LVDV-2T |
| Control / display mode |
5-inch color touch screen |
5-inch color touch screen |
| speed(r/min) |
0.1 – 200 infinitely variable speed,a total of 2000 speed options |
0.1 – 200 infinitely variable speed,a total of 2000 speed options |
| measuring range |
Rotor 1-4: 10 – 2M mPa.s
ULR: 1-1K
Rotor 18: 3 - 1K
Rotor 25: 480 – 1.6M
Rotor 31: 30 - 100K
Rotor 34: 60 - 200K |
Rotor 1-4: 10–6M mPa.s
ULR: 0.3-6K
Rotor 18: 1.5 - 300K
Rotor 25: 240 – 4.8M
Rotor 31: 15 - 300K
Rotor 34: 30 - 600K |
| rotor |
L1 - L4(Standard)
Enhanced ultra-low viscosity adapter ULR (optional)
Small sample adapters (rotors 18,25,31,34)(optional) |
L1 - L4(Standard)
Enhanced ultra-low viscosity adapter ULR (optional)
Small sample adapters (rotors 18,25,31,34)(optional) |
| Sample dosage |
Rotor 1 - 4: 300 - 400ml
ULR: 21ml
Rotor 18: 7ml
Rotor 25: 9ml
Rotor 31: 10.5ml
Rotor 34: 11ml |
Rotor 1 - 4: 300 - 400ml
ULR: 21ml
Rotor 18: 7ml
Rotor 25: 9ml
Rotor 31: 10.5ml
Rotor 34: 11ml |
| measurement erro |
±1% (Newtonian liquid) |
±1% (Newtonian liquid) |
| repetitive error |
±0.5% (Newtonian liquid) |
±0.5% (Newtonian liquid) |
| Show shear response / shear rate |
Can show |
standard configuration |
| Timing function |
have |
standard configuration |
| Real-time display Viscosity curve |
Temperature-time curve
Viscosity-time curve
(The rheological curves of shear rate and viscosity can be displayed by optional data processing software) |
Temperature-time curve
Viscosity-time curve
(The rheological curves of shear rate and viscosity can be displayed by optional data processing software) |
| kinematic viscosity |
Density of samples to be entered |
Density of samples to be entered |
| Temperature measurement function |
Standard temperature probe interface (optional temperature probe) |
Standard temperature probe interface (optional temperature probe) |
| Automatic Scanning Function |
Automatically scan and recommend the preferred combination of rotor and rotation speed |
Automatically scan and recommend the preferred combination of rotor and rotation speed |
| Maximum measurement range |
Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range |
Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range |
| Self-built Measuring Procedures |
Up to 30 groups (including rotor, speed, temperature, time, etc.) |
Up to 30 groups (including rotor, speed, temperature, time, etc.) |
| Preservation of measurements |
Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.) |
Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.) |
| put a seal on |
Data, curve can be printed (standard print interface, need to buy printer) |
Data, curve can be printed (standard print interface, need to buy printer) |
| data output interface |
USB: can insert U disk and copy data directly
RS232: Connect Computer |
USB: can insert U disk and copy data directly
RS232: Connect Computer |
| thermostatic components |
Selections (including various viscometer special thermostatic tank, thermostatic cup, temperature control device, heating furnace) |
Selections (including various viscometer special thermostatic tank, thermostatic cup, temperature control device, heating furnace) |
| working power supply |
Wide voltage operation (110 V/60 Hz or 220 V/50 Hz) |
Wide voltage operation (110 V/60 Hz or 220 V/50 Hz) |
| outline dimension |
300 × 300 × 450(mm) |
300 × 300 × 450(mm) |