Automatic Refractometer AE-A670/A630 – AELAB

The AELAB AE-A670/A630 Automatic Refractometer delivers fast, precise, and reliable measurement of refractive index (nD) and Brix for various liquid samples. Ideal for laboratories and industries requiring FDA 21 CFR Part 11 compliance, it features a high-resolution CCD detector, sapphire prism, and built-in Peltier temperature control system. Designed for accuracy, ease of use, and full digital integration including cloud data storage.
Modles : AE-A670,AE-A630
whatsapp Whatsapp

A670/A630 Automatic Refractometer includes high-performance CCD light-sensitive part, it can automatically measure the refractive index(nD) of transparent, translucent, dark, viscous and other types liquid sample, also can measure sugar degree(Brix) of sugar solution. It’s accurate, reliable, fast, easy operation. Full compliance with FDA 21CFR part.11. A670 innovative use of cloud service systems, all the data from instrument can update to cloud server, especially for group company or government customer, automatic refractometer has a wid range of use, within the field of factories, university and related scientific research institute, petroleum, oil, pharmaceutical, paints, food, daily chemical, sugar and geological prospecting industries.

 

Features:

  1. Multiple Samples Suitability

Automatic Refractometer is widely used on kinds of industries, it is one of the most common instruments in the oil industry, pharmaceutical industry, paint industry, food industry, daily chemical industry, sugar industry, geological exploration or institutions.

  1. Perfect Measuring Prism

Measuring prism is made of high hardness sapphire glass, of excellent properties against corrosion and scratches, free for clean and durable

  1. High Performance CCD Sensor

High-resolution CCD detector offers automatic measurement, avoiding personal errors, having higher accuracy; transparent, translucent liquids or ropiness liquids samples are all available;

  1. Ultra Long Life Light Source

LED cold light source with the long working life more than 100000 hours; Compliance with GLP, FDA 21CFR Part.11 and pharmacopeia.

 

Characteristic

  • Completely meet the requirements of user ID classification & tracking, E-signature, and Data tamper-proof, which listed in FDA CFR21 part.11.
  • High measuring resolution up to 0.00001(nD)/0.01%(Brix) (A670 only)
  • Peltier accurate temperature control system is built-in, accuracy up to 0.02℃
  • Measuring prism is made of high hardness sapphire glass, of excellent properties against corrosion and scratches, free for clean and durable
  • High-resolution CCD detector offers automatic measurement, avoiding personal errors, having higher accuracy; transparent, translucent liquids or ropiness liquids samples are all available;
  • High brightness LED light source with service life more than 100000 hours;
  • 7-inch colour touch screen with LINUX system and 4GB RAM let methods and data expanding excellent
  • 2 x USB, 1 x RS232, 1 x Ethernet, can be easily connected, printer and network to facilitate users to export data or backup.

 

🔍 Recommended Models by Use Case

  • AE-A670: Best suited for advanced research labs, pharmaceutical manufacturers, and companies requiring FDA CFR 21 Part 11 compliance with ultra-high resolution and cloud connectivity.

  • AE-A630: Perfect for quality control departments, educational institutions, and routine industrial applications needing solid precision at lower cost.

 

🧪 Ideal For

  • Pharmaceutical Quality Assurance

  • Food & Beverage Sugar Content Testing

  • Oil & Chemical Refractive Analysis

  • Geological and Petrochemical Studies

  • Cosmetic and Daily Chemical Manufacturing

  • Academic and Government Research Facilities

Specifications :

Model AE-A670 AE-A630
Refractive index measuring range (nD) 1.30000-1.70000 1.30000-1.70000
Measured value error (nD) ±0.0001 ±0.0002
Measurement resolution (nD) 0.0001/0.00001 0.0001
Scope of sugar solution mass fraction (Brix) 0-100% 0-100%
Measured value error (Brix) ±0.1% ±0.1%
Measurement resolution (Brix) 0.1%/0.01% 0.1%
Temperature control mode Built-in semiconductor Built-in semiconductor
Scope of temperature measuring 0-100℃ 0-100℃
Temperature control range 5-80 ℃ 10-50℃
Temperature control accuracy ±0.02℃ ±0.1℃
Output Interface RS232/USB/SD card/

U disk/ Network /Wi-Fi

RS232/USB/SD card/

U disk/Internet

Data storage capacity 4GB 4GB
Display modes 7 inches, TFT touch screen 7 inches, TFT touch screen
Power supply(Power adapter) 110V~240V(12V,10A) 110V~240V(12V,10A)
Power 45W 45W
Net weight 12kg 12kg
Dimensions 365mmX300mmX150mm 365mmX300mmX150mm
Model AE-A670 AE-A630
Refractive index measuring range (nD) 1.30000-1.70000 1.30000-1.70000
Measured value error (nD) ±0.0001 ±0.0002
Measurement resolution (nD) 0.0001/0.00001 0.0001
Scope of sugar solution mass fraction (Brix) 0-100% 0-100%
Measured value error (Brix) ±0.1% ±0.1%
Measurement resolution (Brix) 0.1%/0.01% 0.1%
Temperature control mode Built-in semiconductor Built-in semiconductor
Scope of temperature measuring 0-100℃ 0-100℃
Temperature control range 5-80 ℃ 10-50℃
Temperature control accuracy ±0.02℃ ±0.1℃
Output Interface RS232/USB/SD card/

U disk/ Network /Wi-Fi

RS232/USB/SD card/

U disk/Internet

Data storage capacity 4GB 4GB
Display modes 7 inches, TFT touch screen 7 inches, TFT touch screen
Power supply(Power adapter) 110V~240V(12V,10A) 110V~240V(12V,10A)
Power 45W 45W
Net weight 12kg 12kg
Dimensions 365mmX300mmX150mm 365mmX300mmX150mm

Frequently Asked Questions

1How is calibration performed on the AE-A670/A630?
Calibration is user-friendly via the touchscreen interface using standard reference liquids or certified calibration blocks.
2Is this model FDA 21 CFR Part 11 compliant?
Yes. Both models fully comply, including E-signature, user classification, and data tamper-proof features.
3Can data be exported for reporting?
Absolutely. Data can be exported via USB, RS232, SD card, or through network/Wi-Fi directly to the cloud.
4How long is the warranty?
AELAB offers a 1-year standard warranty with optional extended service contracts.
5Is it suitable for high-viscosity or dark liquids?
Yes. The CCD sensor and LED system enable accurate measurement of dark, viscous, or translucent liquids.

Request Quote: Automatic Refractometer AE-A670/A630 – AELAB