Bench-top XRF spectrometer AE-EDX1800E

According to the wide application of EDX2800B in various fields, EDX1800E is specially designed for better performanceand higher safety protection class.New-generation high-voltage power supply and High efficient tube improves the reliability of the product
Modles : AE-EDX1800E
whatsapp Whatsapp

A bench-top XRF spectrometer designed for RoHS (Restriction of Hazardous Substances) and free halogen analysis is a practical tool for detecting and measuring hazardous elements in various materials. This compact device is specifically engineered to ensure that products comply with environmental and safety regulations by analyzing the presence of restricted substances and halogens.

 

Features:

  • Efficient Analysis: It provides quick and accurate detection of restricted elements such as lead, cadmium, mercury, and other hazardous materials that are regulated under RoHS standards.
  • Free Halogen Testing: The device can identify halogenated compounds, which are crucial for ensuring that products meet standards for being halogen-free, often required for environmental safety and recycling processes.
  • User-Friendly Operation: Designed with simplicity in mind, it offers easy operation with minimal sample preparation, making it accessible for various users, from quality control technicians to environmental compliance officers.
  • Compact and Convenient: Its bench-top size makes it suitable for use in laboratories or production areas without requiring extensive space, ensuring convenient access for routine testing.
  • Non-Destructive: The analysis process does not alter or damage the sample, preserving the integrity of the material being tested.

Specifications :

Standard configurations
  EDX 1800E
Detector New-generation SDD detector made in USA with internationally leading technology, improved resolution and test efficiency.
Pre-amplifier and main amplifier circuit A whole-new design of pre-amplifier and main amplifier circuit, latest micro-electronics modular technology applied, unified design, ensuring more stable technical specifications of the instrument
Test and analysis software whole-new designed professional analysis software, including RoHS& halogen-free alloy number, metal coating thickness, and plating layer thickness measurement fundamental parameter analysis algorithm, support qualitative and quantitative analysis with no standard sample
Technical specifications
Resolution of detector Resolution can reach 144±5eV (measured with Fe55 at counting rate of around 1000/S)
Working scope of tube Copper shell ensures the heat dissipation of the light tube, and greatly increases the service life of the light tube; 5 - 50KV high-voltage; current increased to 1.5mA (the upper limit of the light tube power increased by 50%)
Applications recommended RoHS& halogen-free; alloy number; metal coating and other element analysis
Environmental indicators for heavy metals
RoHS measurement accuracy
1.
1.For about 1000ppm of sample, the accuracy deviation is ±100ppm (plastic sample as standard)
RoHS measurement accuracy
2.
2.For about 100ppm of a sample, the accuracy deviation is ±10ppm (plastic sample as standard)
RoHS detection range 8 hazardous heavy metal elements stated in RoHS, including Cr, Hg, Pb, Br, Cd, Sb, As, Ba can be detected. The special test software can be applied to test other hazardous metal elements; the special test software can be upgraded for free permanently.
Standard configurations
  EDX 1800E
Detector New-generation SDD detector made in USA with internationally leading technology, improved resolution and test efficiency.
Pre-amplifier and main amplifier circuit A whole-new design of pre-amplifier and main amplifier circuit, latest micro-electronics modular technology applied, unified design, ensuring more stable technical specifications of the instrument
Test and analysis software whole-new designed professional analysis software, including RoHS& halogen-free alloy number, metal coating thickness, and plating layer thickness measurement fundamental parameter analysis algorithm, support qualitative and quantitative analysis with no standard sample
Technical specifications
Resolution of detector Resolution can reach 144±5eV (measured with Fe55 at counting rate of around 1000/S)
Working scope of tube Copper shell ensures the heat dissipation of the light tube, and greatly increases the service life of the light tube; 5 - 50KV high-voltage; current increased to 1.5mA (the upper limit of the light tube power increased by 50%)
Applications recommended RoHS& halogen-free; alloy number; metal coating and other element analysis
Environmental indicators for heavy metals
RoHS measurement accuracy
1.
1.For about 1000ppm of sample, the accuracy deviation is ±100ppm (plastic sample as standard)
RoHS measurement accuracy
2.
2.For about 100ppm of a sample, the accuracy deviation is ±10ppm (plastic sample as standard)
RoHS detection range 8 hazardous heavy metal elements stated in RoHS, including Cr, Hg, Pb, Br, Cd, Sb, As, Ba can be detected. The special test software can be applied to test other hazardous metal elements; the special test software can be upgraded for free permanently.