AELAB Real-time PCR System eQ1620 Series – High-Precision DNA & RNA Quantification

The AELAB Real-time PCR System eQ1620 Series delivers fast, accurate, and sensitive DNA/RNA amplification with real-time fluorescent detection. Designed for diagnostics, research, and environmental monitoring, it combines robust temperature control, intuitive software, and flexible models to meet diverse laboratory needs.

Modles : eQ1620、eQ162Cp、eQ164CP
whatsapp Whatsapp

The Real-time PCR System is an advanced tool designed for precise amplification and quantification of DNA and RNA. It utilizes fluorescent dyes to monitor the PCR process in real time, allowing for immediate data analysis. This system is widely used in various applications, including medical diagnostics, genetic research, and environmental monitoring.

Equipped with a thermal cycler, the system ensures accurate temperature control for optimal amplification conditions. Its intuitive software facilitates easy setup and operation, enabling users to design experiments and analyze results efficiently. The system supports multiple sample types and can handle high-throughput requirements, making it ideal for laboratories focused on rapid and reliable results. With its sensitivity and specificity, the Real-time PCR System plays a crucial role in applications such as pathogen detection, gene expression analysis, and genetic variation studies.

 

Features:

  • Fluorescent Detection: Monitors amplification in real time for immediate analysis
  • Precise Temperature Control: Ensures optimal conditions for accurate amplification
  • User-Friendly Software: Simplifies experiment setup and data analysis
  • High-Throughput Capability: Supports multiple samples simultaneously for efficiency
  • Versatile Applications: Suitable for medical diagnostics, genetic research, and environmental monitoring
  • Robust Sensitivity and Specificity: Delivers reliable results for various assays

 

🔬 How It Works?

The eQ1620 Series uses fluorescent dyes and probes to monitor DNA/RNA amplification in real time. The thermal cycler ensures precise heating and cooling cycles, while the high-sensitivity optical module detects fluorescence changes for accurate quantification. With built-in ETSC temperature equalization technology, it delivers uniform amplification and reduces experiment time.

 

💡 Advantages

  • High Sensitivity: Detects as low as 1 copy of nucleic acid.

  • Reliable Accuracy: Advanced Peltier cooling and ETSC compensation ensure stable temperature uniformity

  • Fast Throughput: Multiple samples processed simultaneously with rapid cycling

  • User-Friendly Software: Easy setup, automatic reports, and customizable templates

  • Contamination Control: Built-in UV lamp for effective aerosol degradation

  • Compact Design: Lightweight A4-size footprint for space-saving labs

 

🔍 Recommended Models by Use Case

  • eQ1620: Suitable for academic labs, teaching, and standard diagnostics

  • eQ162Cp: Practical choice for routine clinical labs and QC departments

  • eQ164CP: Best for high-throughput research centers requiring multiplex detection across 4 fluorescent channels

 

🧪 Ideal For

  • Medical Diagnostics: Pathogen detection and genetic disease screening

  • Genetic Research: Gene expression profiling, SNP analysis, mutation detection

  • Environmental Monitoring: Detecting microorganisms and pollutants

  • Food Safety & Agriculture: GMO analysis, contamination testing

  • Pharmaceutical R&D: Drug efficacy, biomarker discovery, and clinical trials

Specifications :

Model eQ1620 eQ162Cp eQ164CP
Sample volume 16*0.2 ml single tube or 8-strip transparent tube (except for white opaque tube), you can mark the tube with markers on the cover of the tube.
Applicable reagents The system is an open platform, suitable for various real-time PCR reagents, including fast extraction reagents, non-extraction reagents or direct amplification reagents and other low-concentration PCR reagents.
Reaction volume 5-100ul
Dynamic range 1-10° Copies
Color wavelength 400-700nm
Optical sensor PMT PD PD
Dyes and probes CH1:FAM、SYBR Greenl ;CH2:HEX、JOE、MC、ROX. CH1: FAM、SYBR Green l ;

CH2:HEX、JOE、VIC、TAMRA;

CH3:ROX、CALRED:

CH4:CY5、QUASAR

Detection technology Scientific grade, suitable for micro-reaction system. Double PD detection, practical grade, suitable for conventional reaction system. Four PD detection,independent excitation fluorescence detection, suitable for multiple PCR.
Unique design of DFD photoelectric module DFD two-dimensional precision photoelectric module, independent 4-color channel, micro-gap direct photometry, high signal-to-noise ratio, Strong ability to resist environmental light interference, The crosstalk between fluorescent channels is very low to avoid misjudgment of amplification results
Sensitivity 1 Copy
Rn >0.998
CV ≤0.6%
Block setting range 10-99.9°C
Temperature control mode Tube mode.Real temperature of simulated reagent.
Refrigeration technology Peltier
ETSC block temperature equalization technology The know-how of block edge temperature self-compensation design (ETSC) not only reduces the weight of the block, but also achieves excellent temperature uniformity, which effectively shortens the time of PCR experiment.
Precision of temperature control ≤0.1°C
Display resolution 0.1°C
Temperature accuracy ≤0.2°C
Temperature uniformity ≤±0.2°C
Max, ramping rate ≥4°C/s
Avg, ramping rate ≥2.5°C/s(50-90°C)
Hot lid 30-105°C, Default 105°C.
Operating mode Operate through PC (provided by customer). one PC can be used to control multiple PcR machines to form N * 16 PCR array to run N PCR experiments simultaneously, which is flexible and changeable.
PC operating system Windows7/10
Com.interface RS232./USB
Software functions It has functions of system settings (password permission), experimental parameter settings, sample information input, operation management, data export EXCEL, general view of PCR program, real-time amplification curve display, channel crosstalk correction, criterion setting, automatic report, curve capture, etc.
Analytical functions Standard curve,Relative Quantitative curve and melting Curve(HRM)
Reports The human/animal experiment report templates are preset in the system, and the report template is also customized. Results Judgment, fluorescence analysis curve, report printing and other functions.
Specialized biodegradation function The built-in ultraviolet lamp (UV) can effectively degrade the aerosol contamination on the block and thermal hot lid, and the irradiation intensity is as high as 7OuW/cm2
Operating indicator Power on, in operation, successful communication, ultraviolet degradation (UV),. fault alarm. hot lid open alarm.
operating ambient Ambient temperature:10-30 °C, relative humidity: 20-85% RH, elevation not higher than 2000 m.storage temperature:-20-60°C
Input power 100-240V~300VA
Dimensions(LxWxH) 324x212x122mm(A4 paper size)
Net weight 5.8Kg
Model eQ1620 eQ162Cp eQ164CP
Sample volume 16*0.2 ml single tube or 8-strip transparent tube (except for white opaque tube), you can mark the tube with markers on the cover of the tube.
Applicable reagents The system is an open platform, suitable for various real-time PCR reagents, including fast extraction reagents, non-extraction reagents or direct amplification reagents and other low-concentration PCR reagents.
Reaction volume 5-100ul
Dynamic range 1-10° Copies
Color wavelength 400-700nm
Optical sensor PMT PD PD
Dyes and probes CH1:FAM、SYBR Greenl ;CH2:HEX、JOE、MC、ROX. CH1: FAM、SYBR Green l ;

CH2:HEX、JOE、VIC、TAMRA;

CH3:ROX、CALRED:

CH4:CY5、QUASAR

Detection technology Scientific grade, suitable for micro-reaction system. Double PD detection, practical grade, suitable for conventional reaction system. Four PD detection,independent excitation fluorescence detection, suitable for multiple PCR.
Unique design of DFD photoelectric module DFD two-dimensional precision photoelectric module, independent 4-color channel, micro-gap direct photometry, high signal-to-noise ratio, Strong ability to resist environmental light interference, The crosstalk between fluorescent channels is very low to avoid misjudgment of amplification results
Sensitivity 1 Copy
Rn >0.998
CV ≤0.6%
Block setting range 10-99.9°C
Temperature control mode Tube mode.Real temperature of simulated reagent.
Refrigeration technology Peltier
ETSC block temperature equalization technology The know-how of block edge temperature self-compensation design (ETSC) not only reduces the weight of the block, but also achieves excellent temperature uniformity, which effectively shortens the time of PCR experiment.
Precision of temperature control ≤0.1°C
Display resolution 0.1°C
Temperature accuracy ≤0.2°C
Temperature uniformity ≤±0.2°C
Max, ramping rate ≥4°C/s
Avg, ramping rate ≥2.5°C/s(50-90°C)
Hot lid 30-105°C, Default 105°C.
Operating mode Operate through PC (provided by customer). one PC can be used to control multiple PcR machines to form N * 16 PCR array to run N PCR experiments simultaneously, which is flexible and changeable.
PC operating system Windows7/10
Com.interface RS232./USB
Software functions It has functions of system settings (password permission), experimental parameter settings, sample information input, operation management, data export EXCEL, general view of PCR program, real-time amplification curve display, channel crosstalk correction, criterion setting, automatic report, curve capture, etc.
Analytical functions Standard curve,Relative Quantitative curve and melting Curve(HRM)
Reports The human/animal experiment report templates are preset in the system, and the report template is also customized. Results Judgment, fluorescence analysis curve, report printing and other functions.
Specialized biodegradation function The built-in ultraviolet lamp (UV) can effectively degrade the aerosol contamination on the block and thermal hot lid, and the irradiation intensity is as high as 7OuW/cm2
Operating indicator Power on, in operation, successful communication, ultraviolet degradation (UV),. fault alarm. hot lid open alarm.
operating ambient Ambient temperature:10-30 °C, relative humidity: 20-85% RH, elevation not higher than 2000 m.storage temperature:-20-60°C
Input power 100-240V~300VA
Dimensions(LxWxH) 324x212x122mm(A4 paper size)
Net weight 5.8Kg

Frequently Asked Questions

1How does the AELAB eQ1620 achieve high sensitivity?
It integrates a DFD precision photoelectric module and independent fluorescence channels, enabling detection down to a single DNA copy with minimal signal interference.
2Can this PCR system run multiple experiments simultaneously?
Yes. One PC can control multiple PCR instruments, forming an N × 16 PCR array for parallel experiments.
3How is contamination prevented during PCR runs?
A built-in UV sterilization system degrades aerosol contamination on the block and hot lid, ensuring clean operation.
4What makes the eQ164CP model ideal for complex assays?
It features four independent detection channels with minimal crosstalk, allowing reliable multiplex PCR for complex genetic studies.
5Is the system suitable for field or compact laboratories?
Yes. With its A4-size footprint and lightweight design, the eQ1620 fits easily into both small labs and portable setups.

Request Quote: AELAB Real-time PCR System eQ1620 Series – High-Precision DNA & RNA Quantification