info@aelabgroup.com
QR Code 1
QR Code 2

AELAB Class II B2 Biological Safety Cabinet – AC Series

The AELAB AC Series Class II B2 Biological Safety Cabinet is engineered for high-containment labs handling biohazards and volatile chemicals. It offers 100% air exhaust with no recirculation, ensuring optimal protection for users, samples, and the environment. With cutting-edge airflow control, ergonomic design, and full compliance, it's an essential tool for advanced biosafety workflows.

Modles : BSC - 1100 II B2 - X~BSC - 1300 II B2 - X~BSC - 1500 II B2 - X~BSC - 1800 II B2 - X
whatsapp Whatsapp

The AC Series Class II B2 Biological Safety Cabinet is designed for laboratories requiring complete air exhaust when working with hazardous biological and chemical materials. It ensures user, product, and environmental protection through advanced airflow control and full containment.

A color screen provides real-time data display and operation scheduling. The 304 stainless steel work zone is surrounded by negative pressure for enhanced safety. The motorized front window with >6mm anti-UV toughened glass is adjustable via a foot switch to minimize airflow disturbance during experiments. A remote control offers added convenience.

Additional features include Footmaster casters with brakes and leveling feet, cabinet support blocks, an iron hook support rod, and a UV lamp emitting at 253.7 nm for effective decontamination. The AC Series offers a practical, safe, and efficient solution for high-containment lab environments.

 

Features:

  1. Color key display: large screen, more clear and dynamic display of various values of the safety cabinet, and has the function of appointment timing.
  2. Automatically adjust the wind speed.
  3. With power – off memory function, the state before power – off will be restored after power – on, and there will be visual prompts and alarms.
  4. The integrated design of the operation area makes it easy to disassemble and clean.
  5. The cabinet is separated from the base. The height of the adjustable base can be customized.
  6. Interlocking function: UV lamp and front window; UV lamp and fan; Fan and front window.
  7. It has the function of appointment timing, which can automatically set the time of starting and shutting down the safety cabinet and the running time of ultraviolet lamps, fans and sockets.
  8. The front window closes the double trigger signal, so that the sterilization and disinfection function of the ultraviolet lamp is normally turned on.
  9. The negative pressure air duct is equipped with a foreign matter filtering structure to prevent foreign matter such as paper scraps from entering the fan system and affecting the normal operation of the product.
  10. The front window glass has a one – key lift function.
  11. The cabinet is designed with a 10° inclination angle, which is in line with ergonomic principles, with a larger viewing angle, convenient operation and more humanization.
  12. The one – piece hand rest has a large surface, which has a larger contact area with the arm and is more comfortable.

 

✅ 🔬 How It Works?

The AC Series Biological Safety Cabinet operates under 100% air exhaust conditions with no internal air recirculation, making it ideal for working with hazardous bio-chemical agents. Ambient air is drawn in through the front grille, forming an air barrier to protect the user. ULPA filters purify the downflow air, ensuring contaminant-free workspace. Contaminated air is entirely exhausted via external ducting, maintaining a clean lab environment. The microprocessor-controlled system provides automated airflow regulation, real-time monitoring, and visual/auditory alerts for operational safety.

 

✅ 💡 Advantages

  • 🛡 Maximum Containment: 100% exhaust airflow with no recirculation—ideal for toxic chemicals and infectious agents.

  • 🧠 Smart Monitoring: LCD screen displays airflow speeds, filter status, lamp usage, and environmental data.

  • 🖥 Remote Operation: Includes foot switch and remote control for seamless hands-free adjustments.

  • 🌬 Advanced Safety Alarms: Alerts for unsafe sash height, airflow velocity, power failures, and filter replacement.

  • Ergonomic & Durable: 10° angled front for better visibility, spacious armrest, and corrosion-resistant stainless steel interior.

  • 🔧 Easy Maintenance: Modular construction allows quick disassembly, cleaning, and filter replacement.

 

✅ 🔍 Recommended Models by Use Case

Model Ideal Use Case
BSC-1100 II B2-X Compact labs with limited space, personal biosafety use
BSC-1300 II B2-X University and hospital diagnostic labs
BSC-1500 II B2-X R&D labs in pharma and biochem industries
BSC-1800 II B2-X High-throughput facilities, QC departments, biohazard containment rooms

 

✅ 🧪 Ideal For

  • Microbiology and virology research labs

  • Biotechnology R&D centers

  • Pharmaceutical QC and formulation labs

  • Hospitals and diagnostic centers

  • BSL-2 and BSL-3 laboratories

  • Food and chemical contamination analysis

  • Forensic toxicology labs

Specifications :

Model BSC - 1100 II B2 - X BSC - 1300 II B2 - X BSC - 1500 II B2 - X BSC - 1800 II B2 - X
External Size (WDH) 11007752250mm 13007752250mm 15007752250mm 18007752250mm
Internal Size (WDH) 940600660mm 1150600660mm 1350600660mm 1625600660mm
Tested Opening Safety height 200mm (8")
Max Opening 480mm
Inflow Velocity 0.53±0.025m/s
Downflow Velocity 0.33±0.025m/s
ULPA Filter Two, 99.9995% efficiency at 0.12μm, filter life indicator
Front Window Motorized. Two - layer laminated toughened glass≥6mm. Anti UV
Noise ≤68 dB
UV Lamp 30W*1
UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination
30W*1 40W*1 40W*1
LED Lamp 12W*2 14W*2 16W*2 16W*2
Illumination ≥1000Lux
Consumption 1300W 1300W 1300W 1300W
Waterproof Socket Two, total load of two sockets: 500W
Display LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.
Control System Microprocessor
Airflow System 0% air recirculation, 100% air exhaust
Visual and Audio Alarm Abnormal airflow velocity, Filter replacement, Front window at unsafe height, High filter pressure alarm, abnormal power failure
Material Work Zone: 304 stainless steel
Main Body: Cold - rolled steel with anti - bacteria powder coating
Work Surface Height 770mm (Can be customized) 800mm (Can be customized)
Caster Footmaster caster
Power Supply AC220V 50/60Hz; 110V 60Hz
Standard Accessory LED lamp 2pcs, UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs, Exhaust blower, Exhaust duct
Optional Accessory Water and gas tap, Electric height adjustable base stand, Armrest
Gross Weight Main Body: 243kg; 52kg
Exhaust Body: 12309901840mm
Main Body: 282kg; 64kg
Exhaust Body: 14309901840mm
Main Body: 300kg; 64kg
Exhaust Body: 16309901840mm
Main Body: 408kg; 64kg
Exhaust Body: 19309901840mm
Package Size (WDH) 930800700mm 930860740mm 930860740mm 930860740mm
Model BSC - 1100 II B2 - X BSC - 1300 II B2 - X BSC - 1500 II B2 - X BSC - 1800 II B2 - X
External Size (WDH) 11007752250mm 13007752250mm 15007752250mm 18007752250mm
Internal Size (WDH) 940600660mm 1150600660mm 1350600660mm 1625600660mm
Tested Opening Safety height 200mm (8")
Max Opening 480mm
Inflow Velocity 0.53±0.025m/s
Downflow Velocity 0.33±0.025m/s
ULPA Filter Two, 99.9995% efficiency at 0.12μm, filter life indicator
Front Window Motorized. Two - layer laminated toughened glass≥6mm. Anti UV
Noise ≤68 dB
UV Lamp 30W*1
UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination
30W*1 40W*1 40W*1
LED Lamp 12W*2 14W*2 16W*2 16W*2
Illumination ≥1000Lux
Consumption 1300W 1300W 1300W 1300W
Waterproof Socket Two, total load of two sockets: 500W
Display LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc.
Control System Microprocessor
Airflow System 0% air recirculation, 100% air exhaust
Visual and Audio Alarm Abnormal airflow velocity, Filter replacement, Front window at unsafe height, High filter pressure alarm, abnormal power failure
Material Work Zone: 304 stainless steel
Main Body: Cold - rolled steel with anti - bacteria powder coating
Work Surface Height 770mm (Can be customized) 800mm (Can be customized)
Caster Footmaster caster
Power Supply AC220V 50/60Hz; 110V 60Hz
Standard Accessory LED lamp 2pcs, UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs, Exhaust blower, Exhaust duct
Optional Accessory Water and gas tap, Electric height adjustable base stand, Armrest
Gross Weight Main Body: 243kg; 52kg
Exhaust Body: 12309901840mm
Main Body: 282kg; 64kg
Exhaust Body: 14309901840mm
Main Body: 300kg; 64kg
Exhaust Body: 16309901840mm
Main Body: 408kg; 64kg
Exhaust Body: 19309901840mm
Package Size (WDH) 930800700mm 930860740mm 930860740mm 930860740mm

Frequently Asked Questions

1How is calibration performed?
AELAB cabinets include a microprocessor-based control system that allows in-situ airflow calibration via sensor tuning. Professional servicing is recommended annually.
2Is the cabinet GMP compliant?
Yes. The AC Series meets GMP requirements with ULPA filtration, real-time data tracking, and material conformity (304 stainless steel work zone).
3What is the warranty period?
The standard warranty is 12 months from the date of installation. Extended warranty options are available upon request.
4Can the height be customized?
Yes, the adjustable base height can be customized per lab requirements. An electric lift version is available as an optional accessory.
5How effective is the UV sterilization?
The UV lamp emits at 253.7 nm, the optimal germicidal wavelength. It includes a timer, life indicator, and interlocks with other components for safe operation.

Looking for specific lab equipment? Fill out the form below, and our team will get back to you with detailed information and a personalized quote.

Request Quote: AELAB Class II B2 Biological Safety Cabinet – AC Series