info@aelabgroup.com
QR Code 1
QR Code 2

AELAB AA-7020 Series Atomic Absorption Spectrometer | Flame & Graphite Furnace for Trace Metal Analysis

The AELAB AA-7020 Series Atomic Absorption Spectrometer integrates flame and graphite furnace techniques for precise quantification of metallic elements in complex samples. Designed for high analytical sensitivity, stability, and automation, it supports up to 70 elements across industrial, environmental, and research laboratories.
Modles : AA-7020 Series
whatsapp Whatsapp

The AELAB AA-7020 Series Atomic Absorption Spectrometer provides dual flame and graphite furnace functionality within a compact, fully integrated analytical system. It is engineered for high-precision metal element determination in metallurgy, petrochemical, environmental, and food science laboratories. The instrument ensures excellent optical stability and trace-level detection for over 70 elements.

 

⚙️ Design & Construction

The AA-7020 Series features a C-T grating optical system with an 1800 lines/mm diffraction grating, automatic bandwidth switching, and Titanium burners. The frame integrates both flame and graphite furnace assemblies, with independent power control and safety protection. The housing is fabricated from corrosion-resistant alloy materials, ensuring long-term stability under demanding laboratory conditions.

 

🔬 Working Principle / Testing Method

The instrument operates on the atomic absorption principle using both flame and electrothermal atomization. The flame system supports air-acetylene and nitrous oxide operation, while the graphite furnace method achieves atomization temperatures up to 3000 °C. Dual background correction—Deuterium lamp and self-absorption—is applied for accurate trace metal quantification. The optical layout ensures repeatable wavelength calibration and superior baseline stability.

 

💡 Key Advantages

  • Integrated flame and graphite furnace design for seamless operation
  • Automatic switch between atomization modes in under 2 seconds
  • High-resolution 0.05 nm wavelength repeatability with 0.1 nm accuracy
  • Programmable temperature control with up to 20 steps for precise furnace operation
  • Deuterium and self-absorption background correction for trace analysis
  • Compact integrated power supply and electronics for stability and energy efficiency
  • High automation for lamp alignment, slit control, and wavelength scanning

 

🔗 Connectivity & Integration

The AELAB AA-7020 includes Ethernet and computer connectivity for data communication, with support for PC workstation software, calibration storage, and result printing. USB and optional printer interfaces are available for GLP-compliant reporting and data archiving.

 

🧠 Model Insight

Model Main Configuration Key Features
AA-7022 Flame atomizer, fast wavelength scan, six-lamp rotating turret Deuterium background correction, self-absorption correction, Ethernet communication
AA-7023 Flame and graphite furnace integration Automatic switching, water-cooled graphite furnace, hydride generator compatibility

 

🧪 Testing Applications

The AELAB AA-7020 Series is suitable for trace metal determination in metallurgy, petrochemical production, environmental protection, food safety, agricultural testing, disease control, and material science laboratories. It quantifies metals such as As, Pb, Cd, Hg, Se, Sb, and Ni at trace concentrations with reliable precision.

 

Compliance & Quality Assurance

The AA-7020 Series complies with ISO and CE laboratory safety standards and supports GLP-traceable calibration. Each instrument undergoes strict optical alignment, background correction validation, and stability testing before delivery under AELAB’s certified quality system.

Specifications :

Optical System
Wavelength Range 190–900 nm
Mono-Chromator C-T Grating Mono-Chromator
Wavelength Accuracy ±0.1 nm
Wavelength Repeatability 0.05 nm
Grating 1800 lines/mm
Spectral Bandwidth Automatic switching between 5 levels: 0.1, 0.2, 0.4, 1.0, 2.0 nm
Blaze Wavelength 250 nm
Baseline Stability ±0.003 A/30 min (Static), ±0.002 A/30 min (Dynamic)
Resolution Better than 0.1 nm

 

Flame Method
Benchmark Concentration of Cu 0.02 g/mL
Detection Limit 0.003 g/mL
Precision RSD 0.6%
Burner Interchangeable full Titanium burner of 50 mm and 100 mm
Position Adjustment Adjustable height and angle
Flame to hydride can be
Detection Limit:0.003 g/ml
Burner:Interchangeable full titanium burner of 50mm and
100 mm
switched in less than 1 minute

 

Graphite Furnace Method
Benchmark Concentration of Cd 0.3 × 10⁻¹² g
Detection Limit 0.2 × 10⁻¹² g
Precision RSD 2%
Temperature Range Room Temperature to 3000 °C
Temperature Control Program Max 20-step temperature program, 3 modes of temperature (step, slope, flat)
Optical Control Temperature Rise Rate 3000 °C/s
Heating Modes Max power heating and optical control rapid heating
Max Power Temperature Rise Rate 2000 °C/s

 

General Configuration
Main Unit Dimensions 880 (L) × 540 (W) × 450 (H) mm
Main Unit Power 200 W
Graphite Furnace Power 4 kW
Power Supply ~220 V 50 Hz single phase
Weight 125 kg
Optical System
Wavelength Range 190–900 nm
Mono-Chromator C-T Grating Mono-Chromator
Wavelength Accuracy ±0.1 nm
Wavelength Repeatability 0.05 nm
Grating 1800 lines/mm
Spectral Bandwidth Automatic switching between 5 levels: 0.1, 0.2, 0.4, 1.0, 2.0 nm
Blaze Wavelength 250 nm
Baseline Stability ±0.003 A/30 min (Static), ±0.002 A/30 min (Dynamic)
Resolution Better than 0.1 nm

 

Flame Method
Benchmark Concentration of Cu 0.02 g/mL
Detection Limit 0.003 g/mL
Precision RSD 0.6%
Burner Interchangeable full Titanium burner of 50 mm and 100 mm
Position Adjustment Adjustable height and angle
Flame to hydride can be
Detection Limit:0.003 g/ml
Burner:Interchangeable full titanium burner of 50mm and
100 mm
switched in less than 1 minute

 

Graphite Furnace Method
Benchmark Concentration of Cd 0.3 × 10⁻¹² g
Detection Limit 0.2 × 10⁻¹² g
Precision RSD 2%
Temperature Range Room Temperature to 3000 °C
Temperature Control Program Max 20-step temperature program, 3 modes of temperature (step, slope, flat)
Optical Control Temperature Rise Rate 3000 °C/s
Heating Modes Max power heating and optical control rapid heating
Max Power Temperature Rise Rate 2000 °C/s

 

General Configuration
Main Unit Dimensions 880 (L) × 540 (W) × 450 (H) mm
Main Unit Power 200 W
Graphite Furnace Power 4 kW
Power Supply ~220 V 50 Hz single phase
Weight 125 kg

Frequently Asked Questions

1What types of analyses can the AELAB AA-7020 perform?
It measures metallic elements in industrial, environmental, food, and clinical samples using both flame and graphite furnace techniques.
2How fast can it switch between flame and graphite furnace modes?
The system switches automatically or manually between modes in less than two seconds without realignment.
3What is the maximum atomization temperature of the graphite furnace?
Up to 3000 °C with a rise rate of 3000 °C/s.
4Does it support background correction?
Yes, it includes both Deuterium lamp and self-absorption background correction systems.
5What are the connectivity options for data output?
Data can be transferred via Ethernet or USB and exported using AELAB workstation software for GLP-compliant reports.

Request Quote: AELAB AA-7020 Series Atomic Absorption Spectrometer | Flame & Graphite Furnace for Trace Metal Analysis