The AELAB ATP-100 fluorescence detector ensures highly sensitive ATP measurement using advanced light shielding, bottom detection technology, and a compact, ergonomic structure. Its rapid response and stable output make it ideal for hygiene monitoring, microbial contamination analysis, and environmental sanitation verification.
Designed for field and laboratory use, the AELAB ATP-100 combines portability with analytical precision, offering reliable results across medical, pharmaceutical, food, and industrial testing workflows.
The ATP-100 features an integrated, sealed optical system to minimize light interference and maximize detection stability. Its durable ABS enclosure and lightweight body (265 g including batteries) allow convenient handheld operation. The instrument operates on dual 1.5V AA batteries and includes a rugged carrying case (B04) for field portability.
The instrument detects Adenosine Triphosphate (ATP) via bioluminescence, converting the emitted light intensity (RLU) into quantifiable ATP concentration. The bottom detection design eliminates interference from positioning or holding angles, ensuring consistent readings. The measurement cycle ranges from 1 to 60 seconds, providing real-time results for hygiene and microbial testing.
The ATP-100 supports USB and RS-232C interfaces for data transmission to PCs or external devices. Results can be exported for traceability or compliance documentation. Optional software enables data management under GLP and ISO protocols.
| Model | Specifications |
|---|---|
| ATP-100 | 0–9999 RLU range, ≤1.0 CFU/ml limit, 1×10⁻¹⁵ mol ATP precision, USB data output, 265 g weight |
The AELAB ATP-100 fluorescence detector is applied in food safety, medical disinfection validation, pharmaceutical quality control, environmental monitoring, and water treatment hygiene testing. It is also suitable for customs inspection, quarantine, and law enforcement bio-detection tasks.
The ATP-100 complies with CE and ISO laboratory quality management standards. Each unit undergoes calibration traceability checks to ensure precision, repeatability, and long-term stability in industrial and diagnostic environments.
Specifications :
| Precision | 1×10⁻¹⁵ mol ATP (standard) |
|---|---|
| Detection Limit | ≤1.0 CFU/ml |
| Detection Range | 0 RLU ~ 9999 RLU (Relative Luminous Unit) |
| Fecal Coliform | ≥1×10⁻⁶ CFU |
| Testing Time | 1 second – 60 seconds |
| Testing Interference | ±5% or ±5 RLUs |
| Background Value | ≤1 RLU |
| Check-out Mode | RLU or Coliform screening |
| Limit Number Setting | More than 1000 |
| Storage Size | More than 3000 |
| Test Results | USB port results can be transferred to a PC |
| Size (W×H×D) | 199 mm × 76 mm × 37 mm |
| Weight (Battery Included) | 265 g |
| Operating Temperature Range | 0 °C ~ 40 °C |
| Relative Humidity Range | 20% ~ 85% |
| Continuous Degree | 600 |
| Power Supply | 2 × 1.5V AA (UM-3) batteries |
| Standard Accessories | Main Unit, Carrying Case (B04) |
| Optional Accessories | Test Swabs, RS-232C Data Cable with Software |
| Precision | 1×10⁻¹⁵ mol ATP (standard) |
|---|---|
| Detection Limit | ≤1.0 CFU/ml |
| Detection Range | 0 RLU ~ 9999 RLU (Relative Luminous Unit) |
| Fecal Coliform | ≥1×10⁻⁶ CFU |
| Testing Time | 1 second – 60 seconds |
| Testing Interference | ±5% or ±5 RLUs |
| Background Value | ≤1 RLU |
| Check-out Mode | RLU or Coliform screening |
| Limit Number Setting | More than 1000 |
| Storage Size | More than 3000 |
| Test Results | USB port results can be transferred to a PC |
| Size (W×H×D) | 199 mm × 76 mm × 37 mm |
| Weight (Battery Included) | 265 g |
| Operating Temperature Range | 0 °C ~ 40 °C |
| Relative Humidity Range | 20% ~ 85% |
| Continuous Degree | 600 |
| Power Supply | 2 × 1.5V AA (UM-3) batteries |
| Standard Accessories | Main Unit, Carrying Case (B04) |
| Optional Accessories | Test Swabs, RS-232C Data Cable with Software |