The AELAB AQMS-450 Carbon Dioxide Analyzer provides precise CO₂ concentration measurement using Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR) technology. Engineered for environmental monitoring, HVAC system validation, and industrial safety, it delivers accurate, low-noise readings with advanced purging and anti-corrosion optical design for stable long-term performance.
The AELAB AQMS-450 Carbon Dioxide Analyzer is a precision instrument engineered for real-time CO₂ quantification in ambient and industrial air environments. Utilizing Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR) detection, it ensures highly accurate, low-drift, and interference-free performance for applications in environmental monitoring, HVAC validation, and industrial air safety compliance.
The AQMS-450 features a white cavity optical chamber combined with an anti-corrosion surface treatment for long-term operational stability. An integrated CO₂ purging device minimizes ambient gas interference, while the precision optical path and signal filtering enhance sensitivity and reduce background noise. Its modular design supports easy maintenance, and the compact rack-mounted form factor enables installation in laboratory benches or mobile monitoring stations.
The AELAB AQMS-450 operates on the GFC-NDIR principle, where infrared radiation passes through a gas filter correlation wheel that alternates between CO₂-absorbing and non-absorbing paths. The difference in detected light intensity corresponds to the CO₂ concentration in the sample gas. This method effectively eliminates cross-sensitivity to other gases, providing precise and repeatable results even in variable environmental conditions. Temperature and pressure are continuously compensated by the onboard processor to maintain measurement integrity.
The analyzer includes RS232, RS485, and Ethernet interfaces for direct connection to SCADA systems, data loggers, and environmental monitoring networks. Analog 4–20 mA output enables integration with control systems or process automation platforms. Classified operation allows automatic data storage, alarm activation, and calibration data retention, ensuring uninterrupted traceability and compliance with air quality management standards.
The AELAB AQMS-450 represents a precise and reliable CO₂ analyzer built for advanced laboratories and environmental agencies. Its enhanced purging and optical stabilization technologies minimize external interferences while maintaining accuracy across extended operation periods. The model supports multiple configurations, including field-deployable and network-integrated versions for regional air quality networks or industrial emission monitoring.
The AELAB AQMS-450 Carbon Dioxide Analyzer complies with ISO 9001 and CE environmental monitoring standards. It supports calibration against certified reference gases, ensuring traceability and repeatable measurement performance. Each analyzer undergoes rigorous quality inspection under controlled laboratory conditions, aligning with GLP and EPA-equivalent testing requirements for environmental data collection and industrial compliance verification.
Specifications :
| Feature | Details |
|---|---|
| Measurement Principle | Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR) |
| Measurement Range | 0–2000 ppm |
| Lower Detectable Limit | <0.2 ppm |
| Zero Noise | Negligible |
| Span Noise | ≤5 ppm |
| Zero Drift (24 h) | ±0.25 ppm |
| Span Drift (24 h) | 1% of reading |
| Precision | ≤5 ppm |
| Response Time | ≤90 s (T90) |
| Sample Flow Rate | 800 cm³/min ±10% |
| Data Transmission | 4–20 mA analog output |
| Output | RS232, RS485, Ethernet |
| Power Requirement | AC 220 V, 50 Hz, ≤350 W |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Dimensions | 178(H) × 432(W) × 604(D) mm |
| Weight | ≤28 kg |
| Accessories | Power cable, communication cables, calibration documentation |
| Feature | Details |
|---|---|
| Measurement Principle | Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR) |
| Measurement Range | 0–2000 ppm |
| Lower Detectable Limit | <0.2 ppm |
| Zero Noise | Negligible |
| Span Noise | ≤5 ppm |
| Zero Drift (24 h) | ±0.25 ppm |
| Span Drift (24 h) | 1% of reading |
| Precision | ≤5 ppm |
| Response Time | ≤90 s (T90) |
| Sample Flow Rate | 800 cm³/min ±10% |
| Data Transmission | 4–20 mA analog output |
| Output | RS232, RS485, Ethernet |
| Power Requirement | AC 220 V, 50 Hz, ≤350 W |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Dimensions | 178(H) × 432(W) × 604(D) mm |
| Weight | ≤28 kg |
| Accessories | Power cable, communication cables, calibration documentation |
Download catalog for: