AELAB GC112A Gas Chromatograph – Advanced Laboratory Analysis System

The AELAB GC112A Gas Chromatograph provides precise analytical separation and quantitative performance for laboratory workflows. Designed for reliable operation across environmental, chemical, petrochemical, and material testing applications, the GC112A ensures stable chromatography, advanced control functions, and consistent analytical throughput.
Modles : GC112A
whatsapp Whatsapp

The AELAB GC112A Gas Chromatograph is engineered for routine and advanced analytical separation applications. It supports high-resolution chromatography, stable thermal control, and laboratory-grade operational reliability suitable for chemical, pharmaceutical, environmental, and industrial laboratories.

The instrument integrates AELAB’s chromatographic control architecture, offering intuitive operation, streamlined workflow handling, and dependable quantitative measurement performance. Full technical details will be completed once the official GC112A catalog file is provided.

 

⚙️ Design & Construction

The structural design, detector layout, oven configuration, and injection system for the AELAB GC112A cannot be fully documented without its model-specific catalog. Once supplied, this section will describe the chassis materials, temperature regulation system, thermal insulation, flow path, and detector architecture with verified quantitative parameters.

 

🔬 Working Principle / Testing Method

The AELAB GC112A operates on standard gas chromatographic separation principles, enabling qualitative and quantitative analysis of volatile and semi-volatile compounds. Detailed explanations of flow control, detector behavior, column heating mode, and injection technology will be added following catalog verification.

 

💡 Key Advantages

  • Supports precise chromatographic separation across a range of chemical and environmental samples
  • Designed for stable temperature control and reproducible analytical performance
  • Compatible with multiple column types and standard laboratory GC workflows
  • Integrates AELAB’s streamlined interface for efficient method operation
  • Suitable for routine QC testing and research-grade applications

 

🔗 Connectivity & Integration

Communication ports, software compatibility, external trigger options, and data acquisition interfaces for the GC112A cannot be specified until the original document is provided. This section will include RS232, USB, LAN, or digital I/O details as applicable.

 

🧠 Model Insight

A responsive table will be generated after receiving the GC112A technical sheet. Example placeholder:

Model Key Specifications
GC112A — To be filled upon catalog submission —

 

🧪 Testing Applications

The AELAB GC112A is suitable for environmental VOC testing, petrochemical composition analysis, pharmaceutical impurity profiling, food safety assessments, and research-grade chromatographic studies.

 

Compliance & Quality Assurance

The GC112A Gas Chromatograph follows AELAB’s manufacturing standards for laboratory analytical instrumentation. Specific CE, ISO or GLP compliance notes will be added following catalog confirmation.

 

Specifications :

Oven
Content product 22L
Temperature control range 5℃ ~ 400℃ at room temperature
Temperature control accuracy ±0.1℃
Heating rate 0.1 ~ 60℃ / min
Program temperature rise order 9
Program heating repeatability ≤ 2%
Cooling way open the door after
Cooling speed ≤10 mins (250℃ ~ 50℃)
Sampler Injector
Temperature control range 7℃ ~ 420℃ at room temperature
Temperature control method independent temperature control
Carrier gas flow control mode constant pressure
Number of simultaneous installations 3 at most
Type of injection unit filling column, shunt
Split ratio split ratio display
Cylinder pressure range 0 ~ 400kPa
Cylinder pressure control accuracy 0.1kPa
Flow setting range H2 0 ~ 200ml / min    N2 0 ~ 150ml / min
Flame Ionization Detector (FID)
Detector type FID, TCD optional
Temperature control Max. 420℃
Number of simultaneous installations 2 at most
Ignition function automatic
Detection limit ≤ 3×10⁻¹² g/s (n-hexadecane)
Baseline noise ≤ 5×10⁻¹⁴ A
Baseline drift ≤ 6×10⁻¹³ A
Dynamic range 10⁷
RSD 3% or less
Thermal Conductivity Detector (TCD)
Sensitivity 5000mV•mL/mg (n-cetane)
Baseline noise ≤ 0.05 mV
Baseline drift ≤ 0.15 mV / 30min
Dynamic range 10⁵
Power & Supply
Supply voltage AC220V±22V, 50Hz±0.5Hz
Power 3000W
Optional Accessories
N2000 chromatography workstation
Packed column
Capillary column
Oven
Content product 22L
Temperature control range 5℃ ~ 400℃ at room temperature
Temperature control accuracy ±0.1℃
Heating rate 0.1 ~ 60℃ / min
Program temperature rise order 9
Program heating repeatability ≤ 2%
Cooling way open the door after
Cooling speed ≤10 mins (250℃ ~ 50℃)
Sampler Injector
Temperature control range 7℃ ~ 420℃ at room temperature
Temperature control method independent temperature control
Carrier gas flow control mode constant pressure
Number of simultaneous installations 3 at most
Type of injection unit filling column, shunt
Split ratio split ratio display
Cylinder pressure range 0 ~ 400kPa
Cylinder pressure control accuracy 0.1kPa
Flow setting range H2 0 ~ 200ml / min    N2 0 ~ 150ml / min
Flame Ionization Detector (FID)
Detector type FID, TCD optional
Temperature control Max. 420℃
Number of simultaneous installations 2 at most
Ignition function automatic
Detection limit ≤ 3×10⁻¹² g/s (n-hexadecane)
Baseline noise ≤ 5×10⁻¹⁴ A
Baseline drift ≤ 6×10⁻¹³ A
Dynamic range 10⁷
RSD 3% or less
Thermal Conductivity Detector (TCD)
Sensitivity 5000mV•mL/mg (n-cetane)
Baseline noise ≤ 0.05 mV
Baseline drift ≤ 0.15 mV / 30min
Dynamic range 10⁵
Power & Supply
Supply voltage AC220V±22V, 50Hz±0.5Hz
Power 3000W
Optional Accessories
N2000 chromatography workstation
Packed column
Capillary column

Frequently Asked Questions

1Does the GC112A support external data export?
Data interfaces and export methods will be clarified once communication specifications are available.
2What detectors are available for the GC112A?
Detector configurations cannot be confirmed until the official catalog is provided.
3What is the temperature control range of the GC112A oven?
This information is missing and will be added immediately once the model datasheet is supplied.
4Is automated injection supported?
Injector type and automation capability cannot be documented without the catalog.