The AELAB GC112A Gas Chromatograph is engineered for routine and advanced analytical separation applications. It supports high-resolution chromatography, stable thermal control, and laboratory-grade operational reliability suitable for chemical, pharmaceutical, environmental, and industrial laboratories.
The instrument integrates AELAB’s chromatographic control architecture, offering intuitive operation, streamlined workflow handling, and dependable quantitative measurement performance. Full technical details will be completed once the official GC112A catalog file is provided.
The structural design, detector layout, oven configuration, and injection system for the AELAB GC112A cannot be fully documented without its model-specific catalog. Once supplied, this section will describe the chassis materials, temperature regulation system, thermal insulation, flow path, and detector architecture with verified quantitative parameters.
The AELAB GC112A operates on standard gas chromatographic separation principles, enabling qualitative and quantitative analysis of volatile and semi-volatile compounds. Detailed explanations of flow control, detector behavior, column heating mode, and injection technology will be added following catalog verification.
Communication ports, software compatibility, external trigger options, and data acquisition interfaces for the GC112A cannot be specified until the original document is provided. This section will include RS232, USB, LAN, or digital I/O details as applicable.
A responsive table will be generated after receiving the GC112A technical sheet. Example placeholder:
| Model | Key Specifications |
|---|---|
| GC112A | — To be filled upon catalog submission — |
The AELAB GC112A is suitable for environmental VOC testing, petrochemical composition analysis, pharmaceutical impurity profiling, food safety assessments, and research-grade chromatographic studies.
The GC112A Gas Chromatograph follows AELAB’s manufacturing standards for laboratory analytical instrumentation. Specific CE, ISO or GLP compliance notes will be added following catalog confirmation.
Specifications :
| Oven | |
|---|---|
| Content product | 22L |
| Temperature control range | 5℃ ~ 400℃ at room temperature |
| Temperature control accuracy | ±0.1℃ |
| Heating rate | 0.1 ~ 60℃ / min |
| Program temperature rise order | 9 |
| Program heating repeatability | ≤ 2% |
| Cooling way | open the door after |
| Cooling speed | ≤10 mins (250℃ ~ 50℃) |
| Sampler Injector | |
| Temperature control range | 7℃ ~ 420℃ at room temperature |
| Temperature control method | independent temperature control |
| Carrier gas flow control mode | constant pressure |
| Number of simultaneous installations | 3 at most |
| Type of injection unit | filling column, shunt |
| Split ratio | split ratio display |
| Cylinder pressure range | 0 ~ 400kPa |
| Cylinder pressure control accuracy | 0.1kPa |
| Flow setting range | H2 0 ~ 200ml / min N2 0 ~ 150ml / min |
| Flame Ionization Detector (FID) | |
| Detector type | FID, TCD optional |
| Temperature control | Max. 420℃ |
| Number of simultaneous installations | 2 at most |
| Ignition function | automatic |
| Detection limit | ≤ 3×10⁻¹² g/s (n-hexadecane) |
| Baseline noise | ≤ 5×10⁻¹⁴ A |
| Baseline drift | ≤ 6×10⁻¹³ A |
| Dynamic range | 10⁷ |
| RSD | 3% or less |
| Thermal Conductivity Detector (TCD) | |
| Sensitivity | 5000mV•mL/mg (n-cetane) |
| Baseline noise | ≤ 0.05 mV |
| Baseline drift | ≤ 0.15 mV / 30min |
| Dynamic range | 10⁵ |
| Power & Supply | |
| Supply voltage | AC220V±22V, 50Hz±0.5Hz |
| Power | 3000W |
| Optional Accessories | |
| N2000 chromatography workstation | |
| Packed column | |
| Capillary column | |
| Oven | |
|---|---|
| Content product | 22L |
| Temperature control range | 5℃ ~ 400℃ at room temperature |
| Temperature control accuracy | ±0.1℃ |
| Heating rate | 0.1 ~ 60℃ / min |
| Program temperature rise order | 9 |
| Program heating repeatability | ≤ 2% |
| Cooling way | open the door after |
| Cooling speed | ≤10 mins (250℃ ~ 50℃) |
| Sampler Injector | |
| Temperature control range | 7℃ ~ 420℃ at room temperature |
| Temperature control method | independent temperature control |
| Carrier gas flow control mode | constant pressure |
| Number of simultaneous installations | 3 at most |
| Type of injection unit | filling column, shunt |
| Split ratio | split ratio display |
| Cylinder pressure range | 0 ~ 400kPa |
| Cylinder pressure control accuracy | 0.1kPa |
| Flow setting range | H2 0 ~ 200ml / min N2 0 ~ 150ml / min |
| Flame Ionization Detector (FID) | |
| Detector type | FID, TCD optional |
| Temperature control | Max. 420℃ |
| Number of simultaneous installations | 2 at most |
| Ignition function | automatic |
| Detection limit | ≤ 3×10⁻¹² g/s (n-hexadecane) |
| Baseline noise | ≤ 5×10⁻¹⁴ A |
| Baseline drift | ≤ 6×10⁻¹³ A |
| Dynamic range | 10⁷ |
| RSD | 3% or less |
| Thermal Conductivity Detector (TCD) | |
| Sensitivity | 5000mV•mL/mg (n-cetane) |
| Baseline noise | ≤ 0.05 mV |
| Baseline drift | ≤ 0.15 mV / 30min |
| Dynamic range | 10⁵ |
| Power & Supply | |
| Supply voltage | AC220V±22V, 50Hz±0.5Hz |
| Power | 3000W |
| Optional Accessories | |
| N2000 chromatography workstation | |
| Packed column | |
| Capillary column | |